Towards Picogram Detection of Superparamagnetic Iron-Oxide Particles Using a Gradiometric Receive Coil

Abstract Superparamagnetic iron-oxide nanoparticles can be used in medical applications like vascular or targeted imaging. Magnetic particle imaging (MPI) is a promising tomographic imaging technique that allows visualizing the 3D nanoparticle distribution concentration in a non-invasive manner. The...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Matthias Graeser, Tobias Knopp, Patryk Szwargulski, Thomas Friedrich, Anselm von Gladiss, Michael Kaul, Kannan M Krishnan, Harald Ittrich, Gerhard Adam, Thorsten M. Buzug
Formato: article
Lenguaje:EN
Publicado: Nature Portfolio 2017
Materias:
R
Q
Acceso en línea:https://doaj.org/article/85d7ea6ccc7e4879acfb9b3bdcd61c0b
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:85d7ea6ccc7e4879acfb9b3bdcd61c0b
record_format dspace
spelling oai:doaj.org-article:85d7ea6ccc7e4879acfb9b3bdcd61c0b2021-12-02T12:32:43ZTowards Picogram Detection of Superparamagnetic Iron-Oxide Particles Using a Gradiometric Receive Coil10.1038/s41598-017-06992-52045-2322https://doaj.org/article/85d7ea6ccc7e4879acfb9b3bdcd61c0b2017-07-01T00:00:00Zhttps://doi.org/10.1038/s41598-017-06992-5https://doaj.org/toc/2045-2322Abstract Superparamagnetic iron-oxide nanoparticles can be used in medical applications like vascular or targeted imaging. Magnetic particle imaging (MPI) is a promising tomographic imaging technique that allows visualizing the 3D nanoparticle distribution concentration in a non-invasive manner. The two main strengths of MPI are high temporal resolution and high sensitivity. While the first has been proven in the assessment of dynamic processes like cardiac imaging, it is unknown how far the detection limit of MPI can be lowered. Within this work, we will present a highly sensitive gradiometric receive-coil unit combined with a noise-matching network tailored for the imaging of mice. The setup is capable of detecting 5 ng of iron in-vitro with an acquisition time of 2.14 sec. In terms of iron concentration we are able to detect 156 μg/L marking the lowest value that has been reported for an MPI scanner so far. In-vivo MPI mouse images of a 512 ng bolus and a 21.5 ms acquisition time allow for capturing the flow of an intravenously injected tracer through the heart of a mouse. Since it has been rather difficult to compare detection limits across MPI publications we propose guidelines to improve the comparability of future MPI studies.Matthias GraeserTobias KnoppPatryk SzwargulskiThomas FriedrichAnselm von GladissMichael KaulKannan M KrishnanHarald IttrichGerhard AdamThorsten M. BuzugNature PortfolioarticleMedicineRScienceQENScientific Reports, Vol 7, Iss 1, Pp 1-13 (2017)
institution DOAJ
collection DOAJ
language EN
topic Medicine
R
Science
Q
spellingShingle Medicine
R
Science
Q
Matthias Graeser
Tobias Knopp
Patryk Szwargulski
Thomas Friedrich
Anselm von Gladiss
Michael Kaul
Kannan M Krishnan
Harald Ittrich
Gerhard Adam
Thorsten M. Buzug
Towards Picogram Detection of Superparamagnetic Iron-Oxide Particles Using a Gradiometric Receive Coil
description Abstract Superparamagnetic iron-oxide nanoparticles can be used in medical applications like vascular or targeted imaging. Magnetic particle imaging (MPI) is a promising tomographic imaging technique that allows visualizing the 3D nanoparticle distribution concentration in a non-invasive manner. The two main strengths of MPI are high temporal resolution and high sensitivity. While the first has been proven in the assessment of dynamic processes like cardiac imaging, it is unknown how far the detection limit of MPI can be lowered. Within this work, we will present a highly sensitive gradiometric receive-coil unit combined with a noise-matching network tailored for the imaging of mice. The setup is capable of detecting 5 ng of iron in-vitro with an acquisition time of 2.14 sec. In terms of iron concentration we are able to detect 156 μg/L marking the lowest value that has been reported for an MPI scanner so far. In-vivo MPI mouse images of a 512 ng bolus and a 21.5 ms acquisition time allow for capturing the flow of an intravenously injected tracer through the heart of a mouse. Since it has been rather difficult to compare detection limits across MPI publications we propose guidelines to improve the comparability of future MPI studies.
format article
author Matthias Graeser
Tobias Knopp
Patryk Szwargulski
Thomas Friedrich
Anselm von Gladiss
Michael Kaul
Kannan M Krishnan
Harald Ittrich
Gerhard Adam
Thorsten M. Buzug
author_facet Matthias Graeser
Tobias Knopp
Patryk Szwargulski
Thomas Friedrich
Anselm von Gladiss
Michael Kaul
Kannan M Krishnan
Harald Ittrich
Gerhard Adam
Thorsten M. Buzug
author_sort Matthias Graeser
title Towards Picogram Detection of Superparamagnetic Iron-Oxide Particles Using a Gradiometric Receive Coil
title_short Towards Picogram Detection of Superparamagnetic Iron-Oxide Particles Using a Gradiometric Receive Coil
title_full Towards Picogram Detection of Superparamagnetic Iron-Oxide Particles Using a Gradiometric Receive Coil
title_fullStr Towards Picogram Detection of Superparamagnetic Iron-Oxide Particles Using a Gradiometric Receive Coil
title_full_unstemmed Towards Picogram Detection of Superparamagnetic Iron-Oxide Particles Using a Gradiometric Receive Coil
title_sort towards picogram detection of superparamagnetic iron-oxide particles using a gradiometric receive coil
publisher Nature Portfolio
publishDate 2017
url https://doaj.org/article/85d7ea6ccc7e4879acfb9b3bdcd61c0b
work_keys_str_mv AT matthiasgraeser towardspicogramdetectionofsuperparamagneticironoxideparticlesusingagradiometricreceivecoil
AT tobiasknopp towardspicogramdetectionofsuperparamagneticironoxideparticlesusingagradiometricreceivecoil
AT patrykszwargulski towardspicogramdetectionofsuperparamagneticironoxideparticlesusingagradiometricreceivecoil
AT thomasfriedrich towardspicogramdetectionofsuperparamagneticironoxideparticlesusingagradiometricreceivecoil
AT anselmvongladiss towardspicogramdetectionofsuperparamagneticironoxideparticlesusingagradiometricreceivecoil
AT michaelkaul towardspicogramdetectionofsuperparamagneticironoxideparticlesusingagradiometricreceivecoil
AT kannanmkrishnan towardspicogramdetectionofsuperparamagneticironoxideparticlesusingagradiometricreceivecoil
AT haraldittrich towardspicogramdetectionofsuperparamagneticironoxideparticlesusingagradiometricreceivecoil
AT gerhardadam towardspicogramdetectionofsuperparamagneticironoxideparticlesusingagradiometricreceivecoil
AT thorstenmbuzug towardspicogramdetectionofsuperparamagneticironoxideparticlesusingagradiometricreceivecoil
_version_ 1718393990392315904