Automated Medical Care: Bradycardia Detection and Cardiac Monitoring of Preterm Infants

<i>Background and Objectives</i>: Prematurity of birth occurs before the 37th week of gestation and affects up to 10% of births worldwide. It is correlated with critical outcomes; therefore, constant monitoring in neonatal intensive care units or home environments is required. The aim of...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Beatrice Arvinti, Emil Radu Iacob, Alexandru Isar, Daniela Iacob, Marius Costache
Formato: article
Lenguaje:EN
Publicado: MDPI AG 2021
Materias:
Acceso en línea:https://doaj.org/article/86562ce011f642e396155ac1d5ba176d
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:86562ce011f642e396155ac1d5ba176d
record_format dspace
spelling oai:doaj.org-article:86562ce011f642e396155ac1d5ba176d2021-11-25T18:18:31ZAutomated Medical Care: Bradycardia Detection and Cardiac Monitoring of Preterm Infants10.3390/medicina571111991648-91441010-660Xhttps://doaj.org/article/86562ce011f642e396155ac1d5ba176d2021-11-01T00:00:00Zhttps://www.mdpi.com/1648-9144/57/11/1199https://doaj.org/toc/1010-660Xhttps://doaj.org/toc/1648-9144<i>Background and Objectives</i>: Prematurity of birth occurs before the 37th week of gestation and affects up to 10% of births worldwide. It is correlated with critical outcomes; therefore, constant monitoring in neonatal intensive care units or home environments is required. The aim of this work was to develop solutions for remote neonatal intensive supervision systems, which should assist medical diagnosis of premature infants and raise alarm at cardiac abnormalities, such as bradycardia. Additionally, the COVID-19 pandemic has put a worldwide stress upon the medical staff and the management of healthcare units. <i>Materials and Methods</i>: A traditional medical diagnosing scheme was set up, implemented with the aid of powerful mathematical operators. The algorithm was tailored to the infants’ personal ECG characteristics and was tested on real ECG data from the publicly available PhysioNet database “Preterm Infant Cardio-Respiratory Signals Database”. Different processing problems were solved: noise filtering, baseline drift removal, event detection and compression of medical data using the à trous wavelet transform. <i>Results</i>: In all 10 available clinical cases, the bradycardia events annotated by the physicians were correctly detected using the RR intervals. Compressing the ECG signals for remote transmission, we obtained compression ratios (CR) varying from 1.72 to 7.42, with the median CR value around 3. <i>Conclusions</i>: We noticed that a significant amount of noise can be added to a signal while monitoring using standard clinical sensors. We tried to offer solutions for these technical problems. Recent studies have shown that persons infected with the COVID-19 disease are frequently reported to develop cardiovascular symptoms and cardiac arrhythmias. An automatic surveillance system (both for neonates and adults) has a practical medical application. The proposed algorithm is personalized, no fixed reference value being applied, and the algorithm follows the neonate’s cardiac rhythm changes. The performance depends on the characteristics of the input ECG. The signal-to-noise ratio of the processed ECG was improved, with a value of up to 10 dB.Beatrice ArvintiEmil Radu IacobAlexandru IsarDaniela IacobMarius CostacheMDPI AGarticleremote monitoringpreterm birthelectrocardiogramarrhythmiaMedicine (General)R5-920ENMedicina, Vol 57, Iss 1199, p 1199 (2021)
institution DOAJ
collection DOAJ
language EN
topic remote monitoring
preterm birth
electrocardiogram
arrhythmia
Medicine (General)
R5-920
spellingShingle remote monitoring
preterm birth
electrocardiogram
arrhythmia
Medicine (General)
R5-920
Beatrice Arvinti
Emil Radu Iacob
Alexandru Isar
Daniela Iacob
Marius Costache
Automated Medical Care: Bradycardia Detection and Cardiac Monitoring of Preterm Infants
description <i>Background and Objectives</i>: Prematurity of birth occurs before the 37th week of gestation and affects up to 10% of births worldwide. It is correlated with critical outcomes; therefore, constant monitoring in neonatal intensive care units or home environments is required. The aim of this work was to develop solutions for remote neonatal intensive supervision systems, which should assist medical diagnosis of premature infants and raise alarm at cardiac abnormalities, such as bradycardia. Additionally, the COVID-19 pandemic has put a worldwide stress upon the medical staff and the management of healthcare units. <i>Materials and Methods</i>: A traditional medical diagnosing scheme was set up, implemented with the aid of powerful mathematical operators. The algorithm was tailored to the infants’ personal ECG characteristics and was tested on real ECG data from the publicly available PhysioNet database “Preterm Infant Cardio-Respiratory Signals Database”. Different processing problems were solved: noise filtering, baseline drift removal, event detection and compression of medical data using the à trous wavelet transform. <i>Results</i>: In all 10 available clinical cases, the bradycardia events annotated by the physicians were correctly detected using the RR intervals. Compressing the ECG signals for remote transmission, we obtained compression ratios (CR) varying from 1.72 to 7.42, with the median CR value around 3. <i>Conclusions</i>: We noticed that a significant amount of noise can be added to a signal while monitoring using standard clinical sensors. We tried to offer solutions for these technical problems. Recent studies have shown that persons infected with the COVID-19 disease are frequently reported to develop cardiovascular symptoms and cardiac arrhythmias. An automatic surveillance system (both for neonates and adults) has a practical medical application. The proposed algorithm is personalized, no fixed reference value being applied, and the algorithm follows the neonate’s cardiac rhythm changes. The performance depends on the characteristics of the input ECG. The signal-to-noise ratio of the processed ECG was improved, with a value of up to 10 dB.
format article
author Beatrice Arvinti
Emil Radu Iacob
Alexandru Isar
Daniela Iacob
Marius Costache
author_facet Beatrice Arvinti
Emil Radu Iacob
Alexandru Isar
Daniela Iacob
Marius Costache
author_sort Beatrice Arvinti
title Automated Medical Care: Bradycardia Detection and Cardiac Monitoring of Preterm Infants
title_short Automated Medical Care: Bradycardia Detection and Cardiac Monitoring of Preterm Infants
title_full Automated Medical Care: Bradycardia Detection and Cardiac Monitoring of Preterm Infants
title_fullStr Automated Medical Care: Bradycardia Detection and Cardiac Monitoring of Preterm Infants
title_full_unstemmed Automated Medical Care: Bradycardia Detection and Cardiac Monitoring of Preterm Infants
title_sort automated medical care: bradycardia detection and cardiac monitoring of preterm infants
publisher MDPI AG
publishDate 2021
url https://doaj.org/article/86562ce011f642e396155ac1d5ba176d
work_keys_str_mv AT beatricearvinti automatedmedicalcarebradycardiadetectionandcardiacmonitoringofpreterminfants
AT emilraduiacob automatedmedicalcarebradycardiadetectionandcardiacmonitoringofpreterminfants
AT alexandruisar automatedmedicalcarebradycardiadetectionandcardiacmonitoringofpreterminfants
AT danielaiacob automatedmedicalcarebradycardiadetectionandcardiacmonitoringofpreterminfants
AT mariuscostache automatedmedicalcarebradycardiadetectionandcardiacmonitoringofpreterminfants
_version_ 1718411392977993728