Can dynamic contour tonometry and ocular pulse amplitude help to detect severe cardiovascular pathologies?

T Bertelmann,1 S Langanke,1 M Potstawa,2 I Strempel11Department of Ophthalmology, Philipps-University of Marburg, Marburg, 2Section Cardiology, Internal Medicine Clinic, Schwalmstadt, GermanyAbstract: We demonstrate the close relationship between a ­conspicuous ocular pulse amplitude and se...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Bertelmann T, Langanke S, Potstawa M, Strempel I
Formato: article
Lenguaje:EN
Publicado: Dove Medical Press 2014
Materias:
Acceso en línea:https://doaj.org/article/8673184acd0a458982a966921cc0c30c
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:8673184acd0a458982a966921cc0c30c
record_format dspace
spelling oai:doaj.org-article:8673184acd0a458982a966921cc0c30c2021-12-02T11:57:15ZCan dynamic contour tonometry and ocular pulse amplitude help to detect severe cardiovascular pathologies?1177-5483https://doaj.org/article/8673184acd0a458982a966921cc0c30c2014-07-01T00:00:00Zhttp://www.dovepress.com/can-dynamic-contour-tonometry-and-ocular-pulse-amplitude-help-to-detec-a17589https://doaj.org/toc/1177-5483 T Bertelmann,1 S Langanke,1 M Potstawa,2 I Strempel11Department of Ophthalmology, Philipps-University of Marburg, Marburg, 2Section Cardiology, Internal Medicine Clinic, Schwalmstadt, GermanyAbstract: We demonstrate the close relationship between a ­conspicuous ocular pulse amplitude and severe underlying cardiovascular disease. Two otherwise symptom-free glaucoma patients without any previously diagnosed underlying cardiovascular pathology but with a conspicuous ocular pulse amplitude and who underwent routine examinations in our glaucoma department were referred to the appropriate specialty for further diagnostic procedures. In both patients, the diagnosis of a tachyarrhythmia was made as suspected on dynamic contour tonometry measurements. In addition to medical treatment, one patient underwent electric cardioversion and the second patient was scheduled for pacemaker implantation. A third patient with an unexpected high ocular pulse amplitude despite severe cardiovascular pathology underwent major surgery due to an aortic aneurysm. Carotid stenosis was diagnosed due to side differences in ocular pulse amplitude as well. Ocular pulse amplitude might be a noninvasive and affordable screening tool and could be used to detect severe cardiovascular disease. A prospective study including a larger number of patients is needed to prove this hypothesis.Keywords: cardiovascular pathology, carotid occlusive disease, dynamic contour tonometry, glaucoma, ocular pulse amplitude, tachyarrhythmiaBertelmann TLanganke SPotstawa MStrempel IDove Medical PressarticleOphthalmologyRE1-994ENClinical Ophthalmology, Vol 2014, Iss default, Pp 1317-1321 (2014)
institution DOAJ
collection DOAJ
language EN
topic Ophthalmology
RE1-994
spellingShingle Ophthalmology
RE1-994
Bertelmann T
Langanke S
Potstawa M
Strempel I
Can dynamic contour tonometry and ocular pulse amplitude help to detect severe cardiovascular pathologies?
description T Bertelmann,1 S Langanke,1 M Potstawa,2 I Strempel11Department of Ophthalmology, Philipps-University of Marburg, Marburg, 2Section Cardiology, Internal Medicine Clinic, Schwalmstadt, GermanyAbstract: We demonstrate the close relationship between a ­conspicuous ocular pulse amplitude and severe underlying cardiovascular disease. Two otherwise symptom-free glaucoma patients without any previously diagnosed underlying cardiovascular pathology but with a conspicuous ocular pulse amplitude and who underwent routine examinations in our glaucoma department were referred to the appropriate specialty for further diagnostic procedures. In both patients, the diagnosis of a tachyarrhythmia was made as suspected on dynamic contour tonometry measurements. In addition to medical treatment, one patient underwent electric cardioversion and the second patient was scheduled for pacemaker implantation. A third patient with an unexpected high ocular pulse amplitude despite severe cardiovascular pathology underwent major surgery due to an aortic aneurysm. Carotid stenosis was diagnosed due to side differences in ocular pulse amplitude as well. Ocular pulse amplitude might be a noninvasive and affordable screening tool and could be used to detect severe cardiovascular disease. A prospective study including a larger number of patients is needed to prove this hypothesis.Keywords: cardiovascular pathology, carotid occlusive disease, dynamic contour tonometry, glaucoma, ocular pulse amplitude, tachyarrhythmia
format article
author Bertelmann T
Langanke S
Potstawa M
Strempel I
author_facet Bertelmann T
Langanke S
Potstawa M
Strempel I
author_sort Bertelmann T
title Can dynamic contour tonometry and ocular pulse amplitude help to detect severe cardiovascular pathologies?
title_short Can dynamic contour tonometry and ocular pulse amplitude help to detect severe cardiovascular pathologies?
title_full Can dynamic contour tonometry and ocular pulse amplitude help to detect severe cardiovascular pathologies?
title_fullStr Can dynamic contour tonometry and ocular pulse amplitude help to detect severe cardiovascular pathologies?
title_full_unstemmed Can dynamic contour tonometry and ocular pulse amplitude help to detect severe cardiovascular pathologies?
title_sort can dynamic contour tonometry and ocular pulse amplitude help to detect severe cardiovascular pathologies?
publisher Dove Medical Press
publishDate 2014
url https://doaj.org/article/8673184acd0a458982a966921cc0c30c
work_keys_str_mv AT bertelmannt candynamiccontourtonometryandocularpulseamplitudehelptodetectseverecardiovascularpathologies
AT langankes candynamiccontourtonometryandocularpulseamplitudehelptodetectseverecardiovascularpathologies
AT potstawam candynamiccontourtonometryandocularpulseamplitudehelptodetectseverecardiovascularpathologies
AT strempeli candynamiccontourtonometryandocularpulseamplitudehelptodetectseverecardiovascularpathologies
_version_ 1718394818967633920