Marginal and internal fit and intaglio surface trueness of interim crowns fabricated from tooth preparation of four finish line locations

Abstract This study evaluated the marginal and internal fit and intaglio surface trueness of interim crowns fabricated from tooth preparation scanned at four finish line locations. The right maxillary first molar tooth preparation model was fabricated using a ceramic material and placed in four fini...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Keunbada Son, Young-Tak Son, Ji-Min Lee, Kyu-Bok Lee
Formato: article
Lenguaje:EN
Publicado: Nature Portfolio 2021
Materias:
R
Q
Acceso en línea:https://doaj.org/article/86d651b992e542c18093c835a5705ba2
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:86d651b992e542c18093c835a5705ba2
record_format dspace
spelling oai:doaj.org-article:86d651b992e542c18093c835a5705ba22021-12-02T18:34:06ZMarginal and internal fit and intaglio surface trueness of interim crowns fabricated from tooth preparation of four finish line locations10.1038/s41598-021-93455-72045-2322https://doaj.org/article/86d651b992e542c18093c835a5705ba22021-07-01T00:00:00Zhttps://doi.org/10.1038/s41598-021-93455-7https://doaj.org/toc/2045-2322Abstract This study evaluated the marginal and internal fit and intaglio surface trueness of interim crowns fabricated from tooth preparation scanned at four finish line locations. The right maxillary first molar tooth preparation model was fabricated using a ceramic material and placed in four finish line locations (supragingival, equigingival, subgingival, and subgingival with a cord). Intraoral scanning was performed. Crowns were designed based on the scanned area. Interim crowns were fabricated using a stereolithography three-dimensional (3D) printer (N = 16 per location). Marginal and internal fit were evaluated with a silicone replica technique. Intaglio surface trueness was evaluated using a 3D inspection software. One-way analysis of variance and Tukey HSD test were performed for comparisons (α = 0.05). The marginal and internal fit showed significant differences according to locations (P < 0.05); the marginal fit showed the best results in the supragingival finish line (P < 0.05). Intaglio surface trueness was significantly different in the marginal region, with the highest value in the subgingival location (P < 0.05). Crowns fabricated on the subgingival finish line caused inaccurate marginal fit due to poor fabrication reproducibility of the marginal region. The use of an intraoral scanner should be decided on the clinical situation and needs.Keunbada SonYoung-Tak SonJi-Min LeeKyu-Bok LeeNature PortfolioarticleMedicineRScienceQENScientific Reports, Vol 11, Iss 1, Pp 1-9 (2021)
institution DOAJ
collection DOAJ
language EN
topic Medicine
R
Science
Q
spellingShingle Medicine
R
Science
Q
Keunbada Son
Young-Tak Son
Ji-Min Lee
Kyu-Bok Lee
Marginal and internal fit and intaglio surface trueness of interim crowns fabricated from tooth preparation of four finish line locations
description Abstract This study evaluated the marginal and internal fit and intaglio surface trueness of interim crowns fabricated from tooth preparation scanned at four finish line locations. The right maxillary first molar tooth preparation model was fabricated using a ceramic material and placed in four finish line locations (supragingival, equigingival, subgingival, and subgingival with a cord). Intraoral scanning was performed. Crowns were designed based on the scanned area. Interim crowns were fabricated using a stereolithography three-dimensional (3D) printer (N = 16 per location). Marginal and internal fit were evaluated with a silicone replica technique. Intaglio surface trueness was evaluated using a 3D inspection software. One-way analysis of variance and Tukey HSD test were performed for comparisons (α = 0.05). The marginal and internal fit showed significant differences according to locations (P < 0.05); the marginal fit showed the best results in the supragingival finish line (P < 0.05). Intaglio surface trueness was significantly different in the marginal region, with the highest value in the subgingival location (P < 0.05). Crowns fabricated on the subgingival finish line caused inaccurate marginal fit due to poor fabrication reproducibility of the marginal region. The use of an intraoral scanner should be decided on the clinical situation and needs.
format article
author Keunbada Son
Young-Tak Son
Ji-Min Lee
Kyu-Bok Lee
author_facet Keunbada Son
Young-Tak Son
Ji-Min Lee
Kyu-Bok Lee
author_sort Keunbada Son
title Marginal and internal fit and intaglio surface trueness of interim crowns fabricated from tooth preparation of four finish line locations
title_short Marginal and internal fit and intaglio surface trueness of interim crowns fabricated from tooth preparation of four finish line locations
title_full Marginal and internal fit and intaglio surface trueness of interim crowns fabricated from tooth preparation of four finish line locations
title_fullStr Marginal and internal fit and intaglio surface trueness of interim crowns fabricated from tooth preparation of four finish line locations
title_full_unstemmed Marginal and internal fit and intaglio surface trueness of interim crowns fabricated from tooth preparation of four finish line locations
title_sort marginal and internal fit and intaglio surface trueness of interim crowns fabricated from tooth preparation of four finish line locations
publisher Nature Portfolio
publishDate 2021
url https://doaj.org/article/86d651b992e542c18093c835a5705ba2
work_keys_str_mv AT keunbadason marginalandinternalfitandintagliosurfacetruenessofinterimcrownsfabricatedfromtoothpreparationoffourfinishlinelocations
AT youngtakson marginalandinternalfitandintagliosurfacetruenessofinterimcrownsfabricatedfromtoothpreparationoffourfinishlinelocations
AT jiminlee marginalandinternalfitandintagliosurfacetruenessofinterimcrownsfabricatedfromtoothpreparationoffourfinishlinelocations
AT kyuboklee marginalandinternalfitandintagliosurfacetruenessofinterimcrownsfabricatedfromtoothpreparationoffourfinishlinelocations
_version_ 1718377929496330240