Comparative Study of Energy Consumption and CO<sub>2</sub> Emissions of Variable-Speed Electric Drives with Induction and Synchronous Reluctance Motors in Pump Units
This study carried out a comparative analysis of indicators of electricity consumption and CO<sub>2</sub> emissions for four-pole induction motors (IMs) of efficiency classes IE3 and IE4 with a rated power of 2.2–200 kW in a variable speed pump unit. In addition, innovative IE4 converter...
Guardado en:
Autores principales: | Victor Goman, Vladimir Prakht, Vadim Kazakbaev, Vladimir Dmitrievskii |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
MDPI AG
2021
|
Materias: | |
Acceso en línea: | https://doaj.org/article/872cfd12ed674b14856b520fbddbc017 |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
Ejemplares similares
-
Analysis of the payback period of a modernized pump unit with induction electric motors of advanced energy efficiency classes
por: V.V. Goman, et al.
Publicado: (2021) -
COMPARISON OF ENERGY CONSUMPTION OF VARIOUS ELECTRICAL MOTORS OPERATING IN A PUMPING UNIT
por: V. V. Goman, et al.
Publicado: (2020) -
ANALYSIS OF ELECTRICITY CONSUMPTION OF INDUCTION MOTORS OF IE1 AND IE2 EFFICIENCY CLASSES IN A 11 kW PUMP INSTALLATION
por: S. Kh. Oshurbekov, et al.
Publicado: (2020) -
Assessment of the Economic Efficiency of the Operation of Low-Emission and Zero-Emission Vehicles in Public Transport in the Countries of the Visegrad Group
por: Sławomir Stec
Publicado: (2021) -
The incorporation of the study into water consumption in energy audits in schools
por: Sánchez-Torija,Jorge Gallego, et al.