Similar stress repartition for a standard uncemented collared femoral stem versus a shortened collared femoral stem

Introduction: The design of uncemented femoral stems for use in total hip arthroplasty has evolved. Several uncemented short stems have been developed with different bone fixations, shapes, or stem lengths. The literature analyzing the biomechanical performance of short to standard stem lengths is l...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Batailler Cécile, Shatrov Jobe, Schmidt Axel, Servien Elvire, Puch Jean Marc, Lustig Sébastien
Formato: article
Lenguaje:EN
Publicado: EDP Sciences 2021
Materias:
Acceso en línea:https://doaj.org/article/882dc71162994f20b674548e1769e83b
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:882dc71162994f20b674548e1769e83b
record_format dspace
spelling oai:doaj.org-article:882dc71162994f20b674548e1769e83b2021-12-02T17:16:12ZSimilar stress repartition for a standard uncemented collared femoral stem versus a shortened collared femoral stem2426-888710.1051/sicotj/2021061https://doaj.org/article/882dc71162994f20b674548e1769e83b2021-01-01T00:00:00Zhttps://www.sicot-j.org/articles/sicotj/full_html/2021/01/sicotj210079/sicotj210079.htmlhttps://doaj.org/toc/2426-8887Introduction: The design of uncemented femoral stems for use in total hip arthroplasty has evolved. Several uncemented short stems have been developed with different bone fixations, shapes, or stem lengths. The literature analyzing the biomechanical performance of short to standard stem lengths is limited. The aim was to compare the stress repartition on a standard uncemented stem and a shortened uncemented femoral stem with the same design features. Material and methods: This finite element analysis assessed the stress repartition on two femoral components with the same design (uncemented, collared, proximal trapezoidal cross-section, and a tapered quadrangular distal stem) but with two different lengths. The shortened stem was shorter by 40 mm compared to the standard stem. The stress repartition was analysed according to the Von Mises criterion. Results: The stress repartition was similar for the standard and shorter stem without significant difference (p = 0.94). The mean Von Mises stress was 58.1 MPa [0.2; 154.1] for the standard stem and 57.2 MPa [0.03; 160.2] for the short stem. The distal part of the standard stem, which was removed in the short stem, had mean stress of 3.7 MPa [0.2; 7.0]. Conclusion: The finite element analysis found similar stress repartitions between a standard uncemented collared stem and a short, collared stem with the same design. A clinical study assessing the clinical outcomes and the bone remodelling with a collared short stem would be interesting to confirm these first promising results.Batailler CécileShatrov JobeSchmidt AxelServien ElvirePuch Jean MarcLustig SébastienEDP Sciencesarticletotal hip arthroplastyshort stemuncemented stemfinite element analysisstress repartitionOrthopedic surgeryRD701-811ENSICOT-J, Vol 7, p 58 (2021)
institution DOAJ
collection DOAJ
language EN
topic total hip arthroplasty
short stem
uncemented stem
finite element analysis
stress repartition
Orthopedic surgery
RD701-811
spellingShingle total hip arthroplasty
short stem
uncemented stem
finite element analysis
stress repartition
Orthopedic surgery
RD701-811
Batailler Cécile
Shatrov Jobe
Schmidt Axel
Servien Elvire
Puch Jean Marc
Lustig Sébastien
Similar stress repartition for a standard uncemented collared femoral stem versus a shortened collared femoral stem
description Introduction: The design of uncemented femoral stems for use in total hip arthroplasty has evolved. Several uncemented short stems have been developed with different bone fixations, shapes, or stem lengths. The literature analyzing the biomechanical performance of short to standard stem lengths is limited. The aim was to compare the stress repartition on a standard uncemented stem and a shortened uncemented femoral stem with the same design features. Material and methods: This finite element analysis assessed the stress repartition on two femoral components with the same design (uncemented, collared, proximal trapezoidal cross-section, and a tapered quadrangular distal stem) but with two different lengths. The shortened stem was shorter by 40 mm compared to the standard stem. The stress repartition was analysed according to the Von Mises criterion. Results: The stress repartition was similar for the standard and shorter stem without significant difference (p = 0.94). The mean Von Mises stress was 58.1 MPa [0.2; 154.1] for the standard stem and 57.2 MPa [0.03; 160.2] for the short stem. The distal part of the standard stem, which was removed in the short stem, had mean stress of 3.7 MPa [0.2; 7.0]. Conclusion: The finite element analysis found similar stress repartitions between a standard uncemented collared stem and a short, collared stem with the same design. A clinical study assessing the clinical outcomes and the bone remodelling with a collared short stem would be interesting to confirm these first promising results.
format article
author Batailler Cécile
Shatrov Jobe
Schmidt Axel
Servien Elvire
Puch Jean Marc
Lustig Sébastien
author_facet Batailler Cécile
Shatrov Jobe
Schmidt Axel
Servien Elvire
Puch Jean Marc
Lustig Sébastien
author_sort Batailler Cécile
title Similar stress repartition for a standard uncemented collared femoral stem versus a shortened collared femoral stem
title_short Similar stress repartition for a standard uncemented collared femoral stem versus a shortened collared femoral stem
title_full Similar stress repartition for a standard uncemented collared femoral stem versus a shortened collared femoral stem
title_fullStr Similar stress repartition for a standard uncemented collared femoral stem versus a shortened collared femoral stem
title_full_unstemmed Similar stress repartition for a standard uncemented collared femoral stem versus a shortened collared femoral stem
title_sort similar stress repartition for a standard uncemented collared femoral stem versus a shortened collared femoral stem
publisher EDP Sciences
publishDate 2021
url https://doaj.org/article/882dc71162994f20b674548e1769e83b
work_keys_str_mv AT bataillercecile similarstressrepartitionforastandarduncementedcollaredfemoralstemversusashortenedcollaredfemoralstem
AT shatrovjobe similarstressrepartitionforastandarduncementedcollaredfemoralstemversusashortenedcollaredfemoralstem
AT schmidtaxel similarstressrepartitionforastandarduncementedcollaredfemoralstemversusashortenedcollaredfemoralstem
AT servienelvire similarstressrepartitionforastandarduncementedcollaredfemoralstemversusashortenedcollaredfemoralstem
AT puchjeanmarc similarstressrepartitionforastandarduncementedcollaredfemoralstemversusashortenedcollaredfemoralstem
AT lustigsebastien similarstressrepartitionforastandarduncementedcollaredfemoralstemversusashortenedcollaredfemoralstem
_version_ 1718381212086566912