Comparisons of amplitude of pseudoaccommodation with aspheric yellow, spheric yellow, and spheric clear monofocal intraocular lenses

Tomo Nishi, Futoshi Taketani, Tetsuo Ueda, Nahoko Ogata Department of Ophthalmology, Nara Medical University, Kashihara City, Nara, Japan Purpose: To determine the amplitude of pseudoaccommodation and higher-order aberrations with three types of implanted monofocal intraocular lenses (IOLs): aspheri...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Nishi T, Taketani F, Ueda T, Ogata N
Formato: article
Lenguaje:EN
Publicado: Dove Medical Press 2013
Materias:
Acceso en línea:https://doaj.org/article/885164de98624240b60f029b4e3081ef
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:885164de98624240b60f029b4e3081ef
record_format dspace
spelling oai:doaj.org-article:885164de98624240b60f029b4e3081ef2021-12-02T00:44:18ZComparisons of amplitude of pseudoaccommodation with aspheric yellow, spheric yellow, and spheric clear monofocal intraocular lenses1177-54671177-5483https://doaj.org/article/885164de98624240b60f029b4e3081ef2013-11-01T00:00:00Zhttp://www.dovepress.com/comparisons-of-amplitude-of-pseudoaccommodation-with-aspheric-yellow-s-a14866https://doaj.org/toc/1177-5467https://doaj.org/toc/1177-5483Tomo Nishi, Futoshi Taketani, Tetsuo Ueda, Nahoko Ogata Department of Ophthalmology, Nara Medical University, Kashihara City, Nara, Japan Purpose: To determine the amplitude of pseudoaccommodation and higher-order aberrations with three types of implanted monofocal intraocular lenses (IOLs): aspheric yellow (IQ); spheric yellow (NT); and spheric clear (AT). Setting: Department of Ophthalmology, Nara Medical University, Nara, Japan. Methods: We studied 60 patients who underwent small incision phacoemulsification with the implantation of a monofocal IQ, NT, or AT IOL. The pseudoaccommodation was measured by the lens-loading method, and the postoperative ocular higher-order aberrations were measured with a Hartmann&ndash;Shack wavefront analyzer through natural and 4 mm pupils. Results: Sixty eyes of 60 patients were studied. The average amplitude of the pseudoaccommodation was 0.45&plusmn;0.24 D with the IQ IOL, which was significantly lower than that with the AT IOL at 0.81&plusmn;0.37 D (Tukey&#39;s test; P<0.01). The differences in the amplitude of the pseudoaccommodation between the IQ and the NT IOLs, and between the NT and the AT IOLs were not significant (Tukey&#39;s test; P>0.05). The degree of spherical aberration was significantly different for the IQ, NT, and AT lenses (analysis of variance, P=0.016). The spherical aberration through the IQ IOL was significantly lower than that through the NT and the AT IOLs (Tukey&#39;s test; P<0.01). The fourth-order RMS (root mean square) aberration of the IQ lens was also significantly lower than that of the NT and AT IOLs (Tukey&#39;s test; P<0.01). Conclusion: Our results suggest that the spherical aberration and selective spectral transmission of IOLs may work together to increase the amplitude of the pseudoaccommodation. Keywords: pseudoaccommodation, aspheric intraocular lens, spheric intraocular lens, higher-order aberrationsNishi TTaketani FUeda TOgata NDove Medical PressarticleOphthalmologyRE1-994ENClinical Ophthalmology, Vol 2013, Iss default, Pp 2159-2164 (2013)
institution DOAJ
collection DOAJ
language EN
topic Ophthalmology
RE1-994
spellingShingle Ophthalmology
RE1-994
Nishi T
Taketani F
Ueda T
Ogata N
Comparisons of amplitude of pseudoaccommodation with aspheric yellow, spheric yellow, and spheric clear monofocal intraocular lenses
description Tomo Nishi, Futoshi Taketani, Tetsuo Ueda, Nahoko Ogata Department of Ophthalmology, Nara Medical University, Kashihara City, Nara, Japan Purpose: To determine the amplitude of pseudoaccommodation and higher-order aberrations with three types of implanted monofocal intraocular lenses (IOLs): aspheric yellow (IQ); spheric yellow (NT); and spheric clear (AT). Setting: Department of Ophthalmology, Nara Medical University, Nara, Japan. Methods: We studied 60 patients who underwent small incision phacoemulsification with the implantation of a monofocal IQ, NT, or AT IOL. The pseudoaccommodation was measured by the lens-loading method, and the postoperative ocular higher-order aberrations were measured with a Hartmann&ndash;Shack wavefront analyzer through natural and 4 mm pupils. Results: Sixty eyes of 60 patients were studied. The average amplitude of the pseudoaccommodation was 0.45&plusmn;0.24 D with the IQ IOL, which was significantly lower than that with the AT IOL at 0.81&plusmn;0.37 D (Tukey&#39;s test; P<0.01). The differences in the amplitude of the pseudoaccommodation between the IQ and the NT IOLs, and between the NT and the AT IOLs were not significant (Tukey&#39;s test; P>0.05). The degree of spherical aberration was significantly different for the IQ, NT, and AT lenses (analysis of variance, P=0.016). The spherical aberration through the IQ IOL was significantly lower than that through the NT and the AT IOLs (Tukey&#39;s test; P<0.01). The fourth-order RMS (root mean square) aberration of the IQ lens was also significantly lower than that of the NT and AT IOLs (Tukey&#39;s test; P<0.01). Conclusion: Our results suggest that the spherical aberration and selective spectral transmission of IOLs may work together to increase the amplitude of the pseudoaccommodation. Keywords: pseudoaccommodation, aspheric intraocular lens, spheric intraocular lens, higher-order aberrations
format article
author Nishi T
Taketani F
Ueda T
Ogata N
author_facet Nishi T
Taketani F
Ueda T
Ogata N
author_sort Nishi T
title Comparisons of amplitude of pseudoaccommodation with aspheric yellow, spheric yellow, and spheric clear monofocal intraocular lenses
title_short Comparisons of amplitude of pseudoaccommodation with aspheric yellow, spheric yellow, and spheric clear monofocal intraocular lenses
title_full Comparisons of amplitude of pseudoaccommodation with aspheric yellow, spheric yellow, and spheric clear monofocal intraocular lenses
title_fullStr Comparisons of amplitude of pseudoaccommodation with aspheric yellow, spheric yellow, and spheric clear monofocal intraocular lenses
title_full_unstemmed Comparisons of amplitude of pseudoaccommodation with aspheric yellow, spheric yellow, and spheric clear monofocal intraocular lenses
title_sort comparisons of amplitude of pseudoaccommodation with aspheric yellow, spheric yellow, and spheric clear monofocal intraocular lenses
publisher Dove Medical Press
publishDate 2013
url https://doaj.org/article/885164de98624240b60f029b4e3081ef
work_keys_str_mv AT nishit comparisonsofamplitudeofpseudoaccommodationwithasphericyellowsphericyellowandsphericclearmonofocalintraocularlenses
AT taketanif comparisonsofamplitudeofpseudoaccommodationwithasphericyellowsphericyellowandsphericclearmonofocalintraocularlenses
AT uedat comparisonsofamplitudeofpseudoaccommodationwithasphericyellowsphericyellowandsphericclearmonofocalintraocularlenses
AT ogatan comparisonsofamplitudeofpseudoaccommodationwithasphericyellowsphericyellowandsphericclearmonofocalintraocularlenses
_version_ 1718403510502948864