Simple benchmarking method for determining the accuracy of depth cameras in body landmark location estimation: Static upright posture as a measurement example.
To evaluate the postures in ergonomics applications, studies have proposed the use of low-cost, marker-less, and portable depth camera-based motion tracking systems (DCMTSs) as a potential alternative to conventional marker-based motion tracking systems (MMTSs). However, a simple but systematic meth...
Guardado en:
Autores principales: | , , , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
Public Library of Science (PLoS)
2021
|
Materias: | |
Acceso en línea: | https://doaj.org/article/88ae119cd56c44ab92ac4411f9930912 |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
Sumario: | To evaluate the postures in ergonomics applications, studies have proposed the use of low-cost, marker-less, and portable depth camera-based motion tracking systems (DCMTSs) as a potential alternative to conventional marker-based motion tracking systems (MMTSs). However, a simple but systematic method for examining the estimation errors of various DCMTSs is lacking. This paper proposes a benchmarking method for assessing the estimation accuracy of depth cameras for full-body landmark location estimation. A novel alignment board was fabricated to align the coordinate systems of the DCMTSs and MMTSs. The data from an MMTS were used as a reference to quantify the error of using a DCMTS to identify target locations in a 3-D space. To demonstrate the proposed method, the full-body landmark location tracking errors were evaluated for a static upright posture using two different DCMTSs. For each landmark, we compared each DCMTS (Kinect system and RealSense system) with an MMTS by calculating the Euclidean distances between symmetrical landmarks. The evaluation trials were performed twice. The agreement between the tracking errors of the two evaluation trials was assessed using intraclass correlation coefficient (ICC). The results indicate that the proposed method can effectively assess the tracking performance of DCMTSs. The average errors (standard deviation) for the Kinect system and RealSense system were 2.80 (1.03) cm and 5.14 (1.49) cm, respectively. The highest average error values were observed in the depth orientation for both DCMTSs. The proposed method achieved high reliability with ICCs of 0.97 and 0.92 for the Kinect system and RealSense system, respectively. |
---|