Simple benchmarking method for determining the accuracy of depth cameras in body landmark location estimation: Static upright posture as a measurement example.

To evaluate the postures in ergonomics applications, studies have proposed the use of low-cost, marker-less, and portable depth camera-based motion tracking systems (DCMTSs) as a potential alternative to conventional marker-based motion tracking systems (MMTSs). However, a simple but systematic meth...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Pin-Ling Liu, Chien-Chi Chang, Jia-Hua Lin, Yoshiyuki Kobayashi
Formato: article
Lenguaje:EN
Publicado: Public Library of Science (PLoS) 2021
Materias:
R
Q
Acceso en línea:https://doaj.org/article/88ae119cd56c44ab92ac4411f9930912
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:88ae119cd56c44ab92ac4411f9930912
record_format dspace
spelling oai:doaj.org-article:88ae119cd56c44ab92ac4411f99309122021-12-02T20:06:46ZSimple benchmarking method for determining the accuracy of depth cameras in body landmark location estimation: Static upright posture as a measurement example.1932-620310.1371/journal.pone.0254814https://doaj.org/article/88ae119cd56c44ab92ac4411f99309122021-01-01T00:00:00Zhttps://doi.org/10.1371/journal.pone.0254814https://doaj.org/toc/1932-6203To evaluate the postures in ergonomics applications, studies have proposed the use of low-cost, marker-less, and portable depth camera-based motion tracking systems (DCMTSs) as a potential alternative to conventional marker-based motion tracking systems (MMTSs). However, a simple but systematic method for examining the estimation errors of various DCMTSs is lacking. This paper proposes a benchmarking method for assessing the estimation accuracy of depth cameras for full-body landmark location estimation. A novel alignment board was fabricated to align the coordinate systems of the DCMTSs and MMTSs. The data from an MMTS were used as a reference to quantify the error of using a DCMTS to identify target locations in a 3-D space. To demonstrate the proposed method, the full-body landmark location tracking errors were evaluated for a static upright posture using two different DCMTSs. For each landmark, we compared each DCMTS (Kinect system and RealSense system) with an MMTS by calculating the Euclidean distances between symmetrical landmarks. The evaluation trials were performed twice. The agreement between the tracking errors of the two evaluation trials was assessed using intraclass correlation coefficient (ICC). The results indicate that the proposed method can effectively assess the tracking performance of DCMTSs. The average errors (standard deviation) for the Kinect system and RealSense system were 2.80 (1.03) cm and 5.14 (1.49) cm, respectively. The highest average error values were observed in the depth orientation for both DCMTSs. The proposed method achieved high reliability with ICCs of 0.97 and 0.92 for the Kinect system and RealSense system, respectively.Pin-Ling LiuChien-Chi ChangJia-Hua LinYoshiyuki KobayashiPublic Library of Science (PLoS)articleMedicineRScienceQENPLoS ONE, Vol 16, Iss 7, p e0254814 (2021)
institution DOAJ
collection DOAJ
language EN
topic Medicine
R
Science
Q
spellingShingle Medicine
R
Science
Q
Pin-Ling Liu
Chien-Chi Chang
Jia-Hua Lin
Yoshiyuki Kobayashi
Simple benchmarking method for determining the accuracy of depth cameras in body landmark location estimation: Static upright posture as a measurement example.
description To evaluate the postures in ergonomics applications, studies have proposed the use of low-cost, marker-less, and portable depth camera-based motion tracking systems (DCMTSs) as a potential alternative to conventional marker-based motion tracking systems (MMTSs). However, a simple but systematic method for examining the estimation errors of various DCMTSs is lacking. This paper proposes a benchmarking method for assessing the estimation accuracy of depth cameras for full-body landmark location estimation. A novel alignment board was fabricated to align the coordinate systems of the DCMTSs and MMTSs. The data from an MMTS were used as a reference to quantify the error of using a DCMTS to identify target locations in a 3-D space. To demonstrate the proposed method, the full-body landmark location tracking errors were evaluated for a static upright posture using two different DCMTSs. For each landmark, we compared each DCMTS (Kinect system and RealSense system) with an MMTS by calculating the Euclidean distances between symmetrical landmarks. The evaluation trials were performed twice. The agreement between the tracking errors of the two evaluation trials was assessed using intraclass correlation coefficient (ICC). The results indicate that the proposed method can effectively assess the tracking performance of DCMTSs. The average errors (standard deviation) for the Kinect system and RealSense system were 2.80 (1.03) cm and 5.14 (1.49) cm, respectively. The highest average error values were observed in the depth orientation for both DCMTSs. The proposed method achieved high reliability with ICCs of 0.97 and 0.92 for the Kinect system and RealSense system, respectively.
format article
author Pin-Ling Liu
Chien-Chi Chang
Jia-Hua Lin
Yoshiyuki Kobayashi
author_facet Pin-Ling Liu
Chien-Chi Chang
Jia-Hua Lin
Yoshiyuki Kobayashi
author_sort Pin-Ling Liu
title Simple benchmarking method for determining the accuracy of depth cameras in body landmark location estimation: Static upright posture as a measurement example.
title_short Simple benchmarking method for determining the accuracy of depth cameras in body landmark location estimation: Static upright posture as a measurement example.
title_full Simple benchmarking method for determining the accuracy of depth cameras in body landmark location estimation: Static upright posture as a measurement example.
title_fullStr Simple benchmarking method for determining the accuracy of depth cameras in body landmark location estimation: Static upright posture as a measurement example.
title_full_unstemmed Simple benchmarking method for determining the accuracy of depth cameras in body landmark location estimation: Static upright posture as a measurement example.
title_sort simple benchmarking method for determining the accuracy of depth cameras in body landmark location estimation: static upright posture as a measurement example.
publisher Public Library of Science (PLoS)
publishDate 2021
url https://doaj.org/article/88ae119cd56c44ab92ac4411f9930912
work_keys_str_mv AT pinlingliu simplebenchmarkingmethodfordeterminingtheaccuracyofdepthcamerasinbodylandmarklocationestimationstaticuprightpostureasameasurementexample
AT chienchichang simplebenchmarkingmethodfordeterminingtheaccuracyofdepthcamerasinbodylandmarklocationestimationstaticuprightpostureasameasurementexample
AT jiahualin simplebenchmarkingmethodfordeterminingtheaccuracyofdepthcamerasinbodylandmarklocationestimationstaticuprightpostureasameasurementexample
AT yoshiyukikobayashi simplebenchmarkingmethodfordeterminingtheaccuracyofdepthcamerasinbodylandmarklocationestimationstaticuprightpostureasameasurementexample
_version_ 1718375371634638848