Implant survival of 662 dual-mobility cups and 727 constrained liners in primary THA: small femoral head size increases the cumulative incidence of revision
Background and purpose — In total hip arthroplasty (THA), the risk for dislocation can be reduced using either dual-mobility cups (DMCs) or constrained liners (CLs). There are few studies comparing these concepts in primary THA. Therefore, we compared the cumulative incidence of revision in primary...
Guardado en:
Autores principales: | , , , , , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
Taylor & Francis Group
2021
|
Materias: | |
Acceso en línea: | https://doaj.org/article/88b495a9f19548f585dd5b8deecc6fae |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:88b495a9f19548f585dd5b8deecc6fae |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:88b495a9f19548f585dd5b8deecc6fae2021-11-26T11:19:47ZImplant survival of 662 dual-mobility cups and 727 constrained liners in primary THA: small femoral head size increases the cumulative incidence of revision1745-36741745-368210.1080/17453674.2021.1939597https://doaj.org/article/88b495a9f19548f585dd5b8deecc6fae2021-10-01T00:00:00Zhttp://dx.doi.org/10.1080/17453674.2021.1939597https://doaj.org/toc/1745-3674https://doaj.org/toc/1745-3682Background and purpose — In total hip arthroplasty (THA), the risk for dislocation can be reduced using either dual-mobility cups (DMCs) or constrained liners (CLs). There are few studies comparing these concepts in primary THA. Therefore, we compared the cumulative incidence of revision in primary THA patients treated with DMC or CL with varying head sizes with conventional THA patients as reference group. Patients and methods — We performed a cohort study based on the Finnish arthroplasty register, comparing DMCs and CLs operated over the period 2000–2017. DMCs were divided into 2 groups based on the implant design: “DMC Trident” group (n = 399) and “DMC Others” group (n = 263). CLs were divided based on the femoral head size: “CL 36 mm” group (n = 425) and “CL < 36 mm” group (n = 302). All conventional primary THAs operated on in 2000–2017 with 28–36 mm femoral head were included as control group (“Conventional THA” group, n = 102,276). Implant survival was calculated by the corresponding cumulative incidence function with revision as the endpoint and death as competing event. Also, the prevalence of different reasons for revision was compared. Results — The 6-year cumulative incidence function estimates for the first revision were 6.9% (95% CI 4.0–9.7) for DMC Trident, 5.0% (CI 1.5–8.5) for DMC Others, 13% (CI 9.3–17) for CL < 36 mm, 6.3% (3.7–8.9) for CL 36 mm, and 4.7% (CI 4.5–4.8) for control group (conventional THA). The prevalence of dislocation revision was high (5.0%, CI 2.9–8.2) in the CL < 36 mm group compared with other groups. Interpretation — The DMC and CL 36 mm groups had promising mid-term survival rates, comparable to those of primary conventional THA group. The revision rate of CLs with < 36 mm head was high, mostly due to high prevalence of dislocation revisions. Therefore, CLs with 36 mm femoral head should be preferred over smaller ones.Oskari PakarinenOlli LainialaAleksi ReitoPerttu NeuvonenKeijo MäkeläAntti EskelinenTaylor & Francis GrouparticleOrthopedic surgeryRD701-811ENActa Orthopaedica, Vol 92, Iss 6, Pp 658-664 (2021) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
Orthopedic surgery RD701-811 |
spellingShingle |
Orthopedic surgery RD701-811 Oskari Pakarinen Olli Lainiala Aleksi Reito Perttu Neuvonen Keijo Mäkelä Antti Eskelinen Implant survival of 662 dual-mobility cups and 727 constrained liners in primary THA: small femoral head size increases the cumulative incidence of revision |
description |
Background and purpose — In total hip arthroplasty (THA), the risk for dislocation can be reduced using either dual-mobility cups (DMCs) or constrained liners (CLs). There are few studies comparing these concepts in primary THA. Therefore, we compared the cumulative incidence of revision in primary THA patients treated with DMC or CL with varying head sizes with conventional THA patients as reference group. Patients and methods — We performed a cohort study based on the Finnish arthroplasty register, comparing DMCs and CLs operated over the period 2000–2017. DMCs were divided into 2 groups based on the implant design: “DMC Trident” group (n = 399) and “DMC Others” group (n = 263). CLs were divided based on the femoral head size: “CL 36 mm” group (n = 425) and “CL < 36 mm” group (n = 302). All conventional primary THAs operated on in 2000–2017 with 28–36 mm femoral head were included as control group (“Conventional THA” group, n = 102,276). Implant survival was calculated by the corresponding cumulative incidence function with revision as the endpoint and death as competing event. Also, the prevalence of different reasons for revision was compared. Results — The 6-year cumulative incidence function estimates for the first revision were 6.9% (95% CI 4.0–9.7) for DMC Trident, 5.0% (CI 1.5–8.5) for DMC Others, 13% (CI 9.3–17) for CL < 36 mm, 6.3% (3.7–8.9) for CL 36 mm, and 4.7% (CI 4.5–4.8) for control group (conventional THA). The prevalence of dislocation revision was high (5.0%, CI 2.9–8.2) in the CL < 36 mm group compared with other groups. Interpretation — The DMC and CL 36 mm groups had promising mid-term survival rates, comparable to those of primary conventional THA group. The revision rate of CLs with < 36 mm head was high, mostly due to high prevalence of dislocation revisions. Therefore, CLs with 36 mm femoral head should be preferred over smaller ones. |
format |
article |
author |
Oskari Pakarinen Olli Lainiala Aleksi Reito Perttu Neuvonen Keijo Mäkelä Antti Eskelinen |
author_facet |
Oskari Pakarinen Olli Lainiala Aleksi Reito Perttu Neuvonen Keijo Mäkelä Antti Eskelinen |
author_sort |
Oskari Pakarinen |
title |
Implant survival of 662 dual-mobility cups and 727 constrained liners in primary THA: small femoral head size increases the cumulative incidence of revision |
title_short |
Implant survival of 662 dual-mobility cups and 727 constrained liners in primary THA: small femoral head size increases the cumulative incidence of revision |
title_full |
Implant survival of 662 dual-mobility cups and 727 constrained liners in primary THA: small femoral head size increases the cumulative incidence of revision |
title_fullStr |
Implant survival of 662 dual-mobility cups and 727 constrained liners in primary THA: small femoral head size increases the cumulative incidence of revision |
title_full_unstemmed |
Implant survival of 662 dual-mobility cups and 727 constrained liners in primary THA: small femoral head size increases the cumulative incidence of revision |
title_sort |
implant survival of 662 dual-mobility cups and 727 constrained liners in primary tha: small femoral head size increases the cumulative incidence of revision |
publisher |
Taylor & Francis Group |
publishDate |
2021 |
url |
https://doaj.org/article/88b495a9f19548f585dd5b8deecc6fae |
work_keys_str_mv |
AT oskaripakarinen implantsurvivalof662dualmobilitycupsand727constrainedlinersinprimarythasmallfemoralheadsizeincreasesthecumulativeincidenceofrevision AT ollilainiala implantsurvivalof662dualmobilitycupsand727constrainedlinersinprimarythasmallfemoralheadsizeincreasesthecumulativeincidenceofrevision AT aleksireito implantsurvivalof662dualmobilitycupsand727constrainedlinersinprimarythasmallfemoralheadsizeincreasesthecumulativeincidenceofrevision AT perttuneuvonen implantsurvivalof662dualmobilitycupsand727constrainedlinersinprimarythasmallfemoralheadsizeincreasesthecumulativeincidenceofrevision AT keijomakela implantsurvivalof662dualmobilitycupsand727constrainedlinersinprimarythasmallfemoralheadsizeincreasesthecumulativeincidenceofrevision AT anttieskelinen implantsurvivalof662dualmobilitycupsand727constrainedlinersinprimarythasmallfemoralheadsizeincreasesthecumulativeincidenceofrevision |
_version_ |
1718409546282565632 |