Investigation of R-Factor for steel moment frame combined with cold-formed steel structures under different load patterns using pushover analysis
The use of Lightweight Steel Frames (LSF) has grown considerably in recent years all over the world due to its unique advantages such as being cost-effective and light-weight, easy and quick installment. Another application is to use them in order to increase the number of new floors on the existing...
Guardado en:
Autores principales: | , |
---|---|
Formato: | article |
Lenguaje: | FA |
Publicado: |
Iranian Society of Structrual Engineering (ISSE)
2017
|
Materias: | |
Acceso en línea: | https://doaj.org/article/88e45f72c09f49b1a92de69f9e7bfaac |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:88e45f72c09f49b1a92de69f9e7bfaac |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:88e45f72c09f49b1a92de69f9e7bfaac2021-11-08T15:46:36ZInvestigation of R-Factor for steel moment frame combined with cold-formed steel structures under different load patterns using pushover analysis2476-39772538-261610.22065/jsce.2017.45903https://doaj.org/article/88e45f72c09f49b1a92de69f9e7bfaac2017-08-01T00:00:00Zhttps://www.jsce.ir/article_45903_618130f1c2e598858b505b914621cc09.pdfhttps://doaj.org/toc/2476-3977https://doaj.org/toc/2538-2616The use of Lightweight Steel Frames (LSF) has grown considerably in recent years all over the world due to its unique advantages such as being cost-effective and light-weight, easy and quick installment. Another application is to use them in order to increase the number of new floors on the existing buildings. But since the behavior of the combined structure is not clear, there is no possibility of increasing new floors with Lightweight Steel Frames. Therefore, through selecting and modeling three buildings of three, five and seven floors with steel moment frames in SAP2000 software and adding one or two new floors using Lightweight Steel Frames (LSF) and conducting a non-linear static analysis with three different lateral load pattern, we dealt with the seismic behavior and determined the behavior coefficient of each of the combined structures. The results indicated that the use of cold-formed structures in order to add story do not have a significant impact on R-factor. In addition, R-factor depends on the type of the side loading pattern.Siavash SadeghiMehran ZeynalianIranian Society of Structrual Engineering (ISSE)articlelight steel frame(lsf)push over analysisincreasing new floorsr factorsteel moment frameBridge engineeringTG1-470Building constructionTH1-9745FAJournal of Structural and Construction Engineering, Vol 4, Iss 2, Pp 161-172 (2017) |
institution |
DOAJ |
collection |
DOAJ |
language |
FA |
topic |
light steel frame(lsf) push over analysis increasing new floors r factor steel moment frame Bridge engineering TG1-470 Building construction TH1-9745 |
spellingShingle |
light steel frame(lsf) push over analysis increasing new floors r factor steel moment frame Bridge engineering TG1-470 Building construction TH1-9745 Siavash Sadeghi Mehran Zeynalian Investigation of R-Factor for steel moment frame combined with cold-formed steel structures under different load patterns using pushover analysis |
description |
The use of Lightweight Steel Frames (LSF) has grown considerably in recent years all over the world due to its unique advantages such as being cost-effective and light-weight, easy and quick installment. Another application is to use them in order to increase the number of new floors on the existing buildings. But since the behavior of the combined structure is not clear, there is no possibility of increasing new floors with Lightweight Steel Frames. Therefore, through selecting and modeling three buildings of three, five and seven floors with steel moment frames in SAP2000 software and adding one or two new floors using Lightweight Steel Frames (LSF) and conducting a non-linear static analysis with three different lateral load pattern, we dealt with the seismic behavior and determined the behavior coefficient of each of the combined structures. The results indicated that the use of cold-formed structures in order to add story do not have a significant impact on R-factor. In addition, R-factor depends on the type of the side loading pattern. |
format |
article |
author |
Siavash Sadeghi Mehran Zeynalian |
author_facet |
Siavash Sadeghi Mehran Zeynalian |
author_sort |
Siavash Sadeghi |
title |
Investigation of R-Factor for steel moment frame combined with cold-formed steel structures under different load patterns using pushover analysis |
title_short |
Investigation of R-Factor for steel moment frame combined with cold-formed steel structures under different load patterns using pushover analysis |
title_full |
Investigation of R-Factor for steel moment frame combined with cold-formed steel structures under different load patterns using pushover analysis |
title_fullStr |
Investigation of R-Factor for steel moment frame combined with cold-formed steel structures under different load patterns using pushover analysis |
title_full_unstemmed |
Investigation of R-Factor for steel moment frame combined with cold-formed steel structures under different load patterns using pushover analysis |
title_sort |
investigation of r-factor for steel moment frame combined with cold-formed steel structures under different load patterns using pushover analysis |
publisher |
Iranian Society of Structrual Engineering (ISSE) |
publishDate |
2017 |
url |
https://doaj.org/article/88e45f72c09f49b1a92de69f9e7bfaac |
work_keys_str_mv |
AT siavashsadeghi investigationofrfactorforsteelmomentframecombinedwithcoldformedsteelstructuresunderdifferentloadpatternsusingpushoveranalysis AT mehranzeynalian investigationofrfactorforsteelmomentframecombinedwithcoldformedsteelstructuresunderdifferentloadpatternsusingpushoveranalysis |
_version_ |
1718441681023401984 |