The strategy of second harmonic voltage match suppression for the DC-link in inverter
In the two-stage converter such as PV renewable energy system, the second harmonic fluctuation exists in the DC voltage due to the power coupling between the DC-link and AC system. The second harmonic voltage in the DC link could increase the system loss and decrease the stability of the converter s...
Guardado en:
Autores principales: | , , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
Elsevier
2022
|
Materias: | |
Acceso en línea: | https://doaj.org/article/89212eaaeeef49fb8bb4bc0aaa7a6d72 |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:89212eaaeeef49fb8bb4bc0aaa7a6d72 |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:89212eaaeeef49fb8bb4bc0aaa7a6d722021-12-04T04:34:56ZThe strategy of second harmonic voltage match suppression for the DC-link in inverter2352-484710.1016/j.egyr.2021.11.077https://doaj.org/article/89212eaaeeef49fb8bb4bc0aaa7a6d722022-04-01T00:00:00Zhttp://www.sciencedirect.com/science/article/pii/S2352484721012221https://doaj.org/toc/2352-4847In the two-stage converter such as PV renewable energy system, the second harmonic fluctuation exists in the DC voltage due to the power coupling between the DC-link and AC system. The second harmonic voltage in the DC link could increase the system loss and decrease the stability of the converter system, and its generation process and transmission mechanism are analyzed in this paper. The mathematical expression of second harmonic voltage in DC-link has been derived. A second band passing filter (BPF) feedback control loop is used to feedback the second harmonic ripple voltage in DC link into the statable modulation index. This strategy can decrease the second harmonic voltage in the DC-link and the third harmonic voltage in the AC sides. Finally, the control parameters are implemented using a simulation platform, and the match suppression strategy is validated by the simulation results.Minghang ZhongXiangqian TongJingjing HuangElsevierarticleSecond harmonic voltagePower couplingBandpass filterMatch suppressionElectrical engineering. Electronics. Nuclear engineeringTK1-9971ENEnergy Reports, Vol 8, Iss , Pp 188-195 (2022) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
Second harmonic voltage Power coupling Bandpass filter Match suppression Electrical engineering. Electronics. Nuclear engineering TK1-9971 |
spellingShingle |
Second harmonic voltage Power coupling Bandpass filter Match suppression Electrical engineering. Electronics. Nuclear engineering TK1-9971 Minghang Zhong Xiangqian Tong Jingjing Huang The strategy of second harmonic voltage match suppression for the DC-link in inverter |
description |
In the two-stage converter such as PV renewable energy system, the second harmonic fluctuation exists in the DC voltage due to the power coupling between the DC-link and AC system. The second harmonic voltage in the DC link could increase the system loss and decrease the stability of the converter system, and its generation process and transmission mechanism are analyzed in this paper. The mathematical expression of second harmonic voltage in DC-link has been derived. A second band passing filter (BPF) feedback control loop is used to feedback the second harmonic ripple voltage in DC link into the statable modulation index. This strategy can decrease the second harmonic voltage in the DC-link and the third harmonic voltage in the AC sides. Finally, the control parameters are implemented using a simulation platform, and the match suppression strategy is validated by the simulation results. |
format |
article |
author |
Minghang Zhong Xiangqian Tong Jingjing Huang |
author_facet |
Minghang Zhong Xiangqian Tong Jingjing Huang |
author_sort |
Minghang Zhong |
title |
The strategy of second harmonic voltage match suppression for the DC-link in inverter |
title_short |
The strategy of second harmonic voltage match suppression for the DC-link in inverter |
title_full |
The strategy of second harmonic voltage match suppression for the DC-link in inverter |
title_fullStr |
The strategy of second harmonic voltage match suppression for the DC-link in inverter |
title_full_unstemmed |
The strategy of second harmonic voltage match suppression for the DC-link in inverter |
title_sort |
strategy of second harmonic voltage match suppression for the dc-link in inverter |
publisher |
Elsevier |
publishDate |
2022 |
url |
https://doaj.org/article/89212eaaeeef49fb8bb4bc0aaa7a6d72 |
work_keys_str_mv |
AT minghangzhong thestrategyofsecondharmonicvoltagematchsuppressionforthedclinkininverter AT xiangqiantong thestrategyofsecondharmonicvoltagematchsuppressionforthedclinkininverter AT jingjinghuang thestrategyofsecondharmonicvoltagematchsuppressionforthedclinkininverter AT minghangzhong strategyofsecondharmonicvoltagematchsuppressionforthedclinkininverter AT xiangqiantong strategyofsecondharmonicvoltagematchsuppressionforthedclinkininverter AT jingjinghuang strategyofsecondharmonicvoltagematchsuppressionforthedclinkininverter |
_version_ |
1718372980743995392 |