Investigation on the Seismic Response Behavior of the Pipe Rack Equipped with Viscos Damper

Pipe racks or pipe bridges are one of the most important refinery structures which are used to maintain pipes and other equipment at the required levels and are usually made of concrete, steel or a combination of these two. Measures should be taken to reduce the damage of piping system due to separa...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Ali Parvari, MohammadAmin Hoshmand
Formato: article
Lenguaje:FA
Publicado: Iranian Society of Structrual Engineering (ISSE) 2021
Materias:
Acceso en línea:https://doaj.org/article/89985a2e971343b1a9a65cac2070b490
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:89985a2e971343b1a9a65cac2070b490
record_format dspace
spelling oai:doaj.org-article:89985a2e971343b1a9a65cac2070b4902021-11-08T15:55:01ZInvestigation on the Seismic Response Behavior of the Pipe Rack Equipped with Viscos Damper2476-39772538-261610.22065/jsce.2020.161187.1742https://doaj.org/article/89985a2e971343b1a9a65cac2070b4902021-08-01T00:00:00Zhttps://www.jsce.ir/article_104576_bf87b9c858f208194323a5195c74f9dc.pdfhttps://doaj.org/toc/2476-3977https://doaj.org/toc/2538-2616Pipe racks or pipe bridges are one of the most important refinery structures which are used to maintain pipes and other equipment at the required levels and are usually made of concrete, steel or a combination of these two. Measures should be taken to reduce the damage of piping system due to separation of pipe-racks, the separate behavior of each of these parts during the earthquake, and also the large force involved in the separation of the pipe supports. Dampers are one of the most powerful earthquake engineering tools as a passive control system. Although the use of dampers in pipe-rack structures is unusual, it can be very useful in some cases. In this study, the function of dampers in a four-part pipe-rack under the influence of faults near faults and earthquakes was investigated. Our Findings revealed that when dampers placed in a longitudinal braces, the use of dampers in the pipe-rack has a very good performance and reduces the damage to the structures and piping system after the earthquake. Adding dampers to these structures can dramatically reduce the inter-levels drainage and acceleration of floors, and thus protect the pipes. In this way, these structures can fully maintain their usability during the earthquake and can be exploited immediately after the earthquake, which is very important in refineries.Ali ParvariMohammadAmin HoshmandIranian Society of Structrual Engineering (ISSE)articlestructure controlseismic responsepipe rackviscos dampertime history analysisBridge engineeringTG1-470Building constructionTH1-9745FAJournal of Structural and Construction Engineering, Vol 8, Iss 6, Pp 81-96 (2021)
institution DOAJ
collection DOAJ
language FA
topic structure control
seismic response
pipe rack
viscos damper
time history analysis
Bridge engineering
TG1-470
Building construction
TH1-9745
spellingShingle structure control
seismic response
pipe rack
viscos damper
time history analysis
Bridge engineering
TG1-470
Building construction
TH1-9745
Ali Parvari
MohammadAmin Hoshmand
Investigation on the Seismic Response Behavior of the Pipe Rack Equipped with Viscos Damper
description Pipe racks or pipe bridges are one of the most important refinery structures which are used to maintain pipes and other equipment at the required levels and are usually made of concrete, steel or a combination of these two. Measures should be taken to reduce the damage of piping system due to separation of pipe-racks, the separate behavior of each of these parts during the earthquake, and also the large force involved in the separation of the pipe supports. Dampers are one of the most powerful earthquake engineering tools as a passive control system. Although the use of dampers in pipe-rack structures is unusual, it can be very useful in some cases. In this study, the function of dampers in a four-part pipe-rack under the influence of faults near faults and earthquakes was investigated. Our Findings revealed that when dampers placed in a longitudinal braces, the use of dampers in the pipe-rack has a very good performance and reduces the damage to the structures and piping system after the earthquake. Adding dampers to these structures can dramatically reduce the inter-levels drainage and acceleration of floors, and thus protect the pipes. In this way, these structures can fully maintain their usability during the earthquake and can be exploited immediately after the earthquake, which is very important in refineries.
format article
author Ali Parvari
MohammadAmin Hoshmand
author_facet Ali Parvari
MohammadAmin Hoshmand
author_sort Ali Parvari
title Investigation on the Seismic Response Behavior of the Pipe Rack Equipped with Viscos Damper
title_short Investigation on the Seismic Response Behavior of the Pipe Rack Equipped with Viscos Damper
title_full Investigation on the Seismic Response Behavior of the Pipe Rack Equipped with Viscos Damper
title_fullStr Investigation on the Seismic Response Behavior of the Pipe Rack Equipped with Viscos Damper
title_full_unstemmed Investigation on the Seismic Response Behavior of the Pipe Rack Equipped with Viscos Damper
title_sort investigation on the seismic response behavior of the pipe rack equipped with viscos damper
publisher Iranian Society of Structrual Engineering (ISSE)
publishDate 2021
url https://doaj.org/article/89985a2e971343b1a9a65cac2070b490
work_keys_str_mv AT aliparvari investigationontheseismicresponsebehaviorofthepiperackequippedwithviscosdamper
AT mohammadaminhoshmand investigationontheseismicresponsebehaviorofthepiperackequippedwithviscosdamper
_version_ 1718441582018953216