Evaluating the repeatability of corneal elevation through calculating the misalignment between Successive topography measurements during the follow up of LASIK
Abstract The study aims to evaluate, using the Iterative Closest Point (ICP) algorithm, the repeatability of successive corneal elevation measurements taken post-LASIK. Two topography maps of 98 LASIK participants were recorded preoperatively (Pre), 1 month (Pos1M) and 3 months postoperatively (Pos3...
Guardado en:
Autores principales: | , , , , , , , , , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
Nature Portfolio
2017
|
Materias: | |
Acceso en línea: | https://doaj.org/article/8a55845de3f34e6ea23bd27ad892decb |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:8a55845de3f34e6ea23bd27ad892decb |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:8a55845de3f34e6ea23bd27ad892decb2021-12-02T16:06:12ZEvaluating the repeatability of corneal elevation through calculating the misalignment between Successive topography measurements during the follow up of LASIK10.1038/s41598-017-03223-92045-2322https://doaj.org/article/8a55845de3f34e6ea23bd27ad892decb2017-06-01T00:00:00Zhttps://doi.org/10.1038/s41598-017-03223-9https://doaj.org/toc/2045-2322Abstract The study aims to evaluate, using the Iterative Closest Point (ICP) algorithm, the repeatability of successive corneal elevation measurements taken post-LASIK. Two topography maps of 98 LASIK participants were recorded preoperatively (Pre), 1 month (Pos1M) and 3 months postoperatively (Pos3M). Elevation of the second measurement was fitted to the first measurement by calculating using ICP, and correcting for, both translational and rotational misalignment components. The RMS of elevation differences between anterior corneal measurements were statistically significant post-LASIK compared to preoperation (P < 0.05). A misalignment ratio used to describe the weighting of the elevation difference caused by misalignment relative to the total difference remained stable (0.40 and 0.23 for anterior and posterior corneal surfaces, respectively) in different periods. The study also considered the combined misalignment parameter (CM), which represents the total effect of all individual misalignment components on the repeatability of corneal topography maps. CM was significantly greater post-LASIK relative to pre-LASIK (P < 0.05). Overall, the contribution of misalignment to the total difference between successive corneal measurements remained stable pre and post operation, while the combined effect of refractive error correction and optical diameter appeared to have a significant influence on the elevation repeatability in the early stages of the follow up period.XiaoBo ZhengWeiHua YangLiFang HuangJunJie WangSi CaoBrendan GeraghtyYiPing ZhaoQinMei WangFangJun BaoAhmed ElsheikhNature PortfolioarticleMedicineRScienceQENScientific Reports, Vol 7, Iss 1, Pp 1-7 (2017) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
Medicine R Science Q |
spellingShingle |
Medicine R Science Q XiaoBo Zheng WeiHua Yang LiFang Huang JunJie Wang Si Cao Brendan Geraghty YiPing Zhao QinMei Wang FangJun Bao Ahmed Elsheikh Evaluating the repeatability of corneal elevation through calculating the misalignment between Successive topography measurements during the follow up of LASIK |
description |
Abstract The study aims to evaluate, using the Iterative Closest Point (ICP) algorithm, the repeatability of successive corneal elevation measurements taken post-LASIK. Two topography maps of 98 LASIK participants were recorded preoperatively (Pre), 1 month (Pos1M) and 3 months postoperatively (Pos3M). Elevation of the second measurement was fitted to the first measurement by calculating using ICP, and correcting for, both translational and rotational misalignment components. The RMS of elevation differences between anterior corneal measurements were statistically significant post-LASIK compared to preoperation (P < 0.05). A misalignment ratio used to describe the weighting of the elevation difference caused by misalignment relative to the total difference remained stable (0.40 and 0.23 for anterior and posterior corneal surfaces, respectively) in different periods. The study also considered the combined misalignment parameter (CM), which represents the total effect of all individual misalignment components on the repeatability of corneal topography maps. CM was significantly greater post-LASIK relative to pre-LASIK (P < 0.05). Overall, the contribution of misalignment to the total difference between successive corneal measurements remained stable pre and post operation, while the combined effect of refractive error correction and optical diameter appeared to have a significant influence on the elevation repeatability in the early stages of the follow up period. |
format |
article |
author |
XiaoBo Zheng WeiHua Yang LiFang Huang JunJie Wang Si Cao Brendan Geraghty YiPing Zhao QinMei Wang FangJun Bao Ahmed Elsheikh |
author_facet |
XiaoBo Zheng WeiHua Yang LiFang Huang JunJie Wang Si Cao Brendan Geraghty YiPing Zhao QinMei Wang FangJun Bao Ahmed Elsheikh |
author_sort |
XiaoBo Zheng |
title |
Evaluating the repeatability of corneal elevation through calculating the misalignment between Successive topography measurements during the follow up of LASIK |
title_short |
Evaluating the repeatability of corneal elevation through calculating the misalignment between Successive topography measurements during the follow up of LASIK |
title_full |
Evaluating the repeatability of corneal elevation through calculating the misalignment between Successive topography measurements during the follow up of LASIK |
title_fullStr |
Evaluating the repeatability of corneal elevation through calculating the misalignment between Successive topography measurements during the follow up of LASIK |
title_full_unstemmed |
Evaluating the repeatability of corneal elevation through calculating the misalignment between Successive topography measurements during the follow up of LASIK |
title_sort |
evaluating the repeatability of corneal elevation through calculating the misalignment between successive topography measurements during the follow up of lasik |
publisher |
Nature Portfolio |
publishDate |
2017 |
url |
https://doaj.org/article/8a55845de3f34e6ea23bd27ad892decb |
work_keys_str_mv |
AT xiaobozheng evaluatingtherepeatabilityofcornealelevationthroughcalculatingthemisalignmentbetweensuccessivetopographymeasurementsduringthefollowupoflasik AT weihuayang evaluatingtherepeatabilityofcornealelevationthroughcalculatingthemisalignmentbetweensuccessivetopographymeasurementsduringthefollowupoflasik AT lifanghuang evaluatingtherepeatabilityofcornealelevationthroughcalculatingthemisalignmentbetweensuccessivetopographymeasurementsduringthefollowupoflasik AT junjiewang evaluatingtherepeatabilityofcornealelevationthroughcalculatingthemisalignmentbetweensuccessivetopographymeasurementsduringthefollowupoflasik AT sicao evaluatingtherepeatabilityofcornealelevationthroughcalculatingthemisalignmentbetweensuccessivetopographymeasurementsduringthefollowupoflasik AT brendangeraghty evaluatingtherepeatabilityofcornealelevationthroughcalculatingthemisalignmentbetweensuccessivetopographymeasurementsduringthefollowupoflasik AT yipingzhao evaluatingtherepeatabilityofcornealelevationthroughcalculatingthemisalignmentbetweensuccessivetopographymeasurementsduringthefollowupoflasik AT qinmeiwang evaluatingtherepeatabilityofcornealelevationthroughcalculatingthemisalignmentbetweensuccessivetopographymeasurementsduringthefollowupoflasik AT fangjunbao evaluatingtherepeatabilityofcornealelevationthroughcalculatingthemisalignmentbetweensuccessivetopographymeasurementsduringthefollowupoflasik AT ahmedelsheikh evaluatingtherepeatabilityofcornealelevationthroughcalculatingthemisalignmentbetweensuccessivetopographymeasurementsduringthefollowupoflasik |
_version_ |
1718385099926405120 |