The Sensimed Triggerfish contact lens sensor: efficacy, safety, and patient perspectives
Grace E Dunbar, Bailey Yuguan Shen, Ahmad A Aref Illinois Eye and Ear Infirmary, Department of Ophthalmology and Visual Sciences, University of Illinois at Chicago, Chicago, IL, USA Abstract: Intraocular pressure, a major modifiable risk factor for glaucoma, has been shown to fluctuate throughout...
Guardado en:
Autores principales: | , , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
Dove Medical Press
2017
|
Materias: | |
Acceso en línea: | https://doaj.org/article/8b3d65f8e68f406c828dbbbe041a1439 |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:8b3d65f8e68f406c828dbbbe041a1439 |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:8b3d65f8e68f406c828dbbbe041a14392021-12-02T06:10:39ZThe Sensimed Triggerfish contact lens sensor: efficacy, safety, and patient perspectives1177-5483https://doaj.org/article/8b3d65f8e68f406c828dbbbe041a14392017-05-01T00:00:00Zhttps://www.dovepress.com/the-sensimed-triggerfish-contact-lens-sensor-efficacy-safety-and-patie-peer-reviewed-article-OPTHhttps://doaj.org/toc/1177-5483Grace E Dunbar, Bailey Yuguan Shen, Ahmad A Aref Illinois Eye and Ear Infirmary, Department of Ophthalmology and Visual Sciences, University of Illinois at Chicago, Chicago, IL, USA Abstract: Intraocular pressure, a major modifiable risk factor for glaucoma, has been shown to fluctuate throughout the day in patients with glaucoma. The detection and measurement of this fluctuation may help guide the clinical management of glaucomatous individuals. The Sensimed Triggerfish contact lens sensor (CLS), which has recently gained approval for marketing in the USA, is designed to detect intraocular pressure-related changes in an eye over a 24-hour period. This review will provide an overview of the Triggerfish CLS, as well as summarize current clinical data pertaining to the device. Overall, the current evidence suggests that the Triggerfish CLS is safe and well tolerated, and provides reproducible results. One challenge of using the Triggerfish CLS is that it may only provide data on relative changes in intraocular pressure rather than absolute intraocular pressure. In addition, its validity at estimating intraocular pressure compared to other methods is still controversial. Despite these limitations, recent studies suggest a myriad of potential indications for the Triggerfish CLS, including predicting glaucomatous progression and predicting efficacy of glaucoma treatment. With further research, the Triggerfish CLS may become a useful tool for eye care practitioners. Keywords: glaucoma, intraocular pressure, contact lens sensor, triggerfish CLS, Sensimed, 24-hour intraocular pressure monitoringDunbar GEShen BYAref AADove Medical PressarticleGlaucomaIntraocular PressureContact Lens SensorTriggerfishSensimedTwenty-four hour Intraocular Pressure MonitoringOphthalmologyRE1-994ENClinical Ophthalmology, Vol Volume 11, Pp 875-882 (2017) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
Glaucoma Intraocular Pressure Contact Lens Sensor Triggerfish Sensimed Twenty-four hour Intraocular Pressure Monitoring Ophthalmology RE1-994 |
spellingShingle |
Glaucoma Intraocular Pressure Contact Lens Sensor Triggerfish Sensimed Twenty-four hour Intraocular Pressure Monitoring Ophthalmology RE1-994 Dunbar GE Shen BY Aref AA The Sensimed Triggerfish contact lens sensor: efficacy, safety, and patient perspectives |
description |
Grace E Dunbar, Bailey Yuguan Shen, Ahmad A Aref Illinois Eye and Ear Infirmary, Department of Ophthalmology and Visual Sciences, University of Illinois at Chicago, Chicago, IL, USA Abstract: Intraocular pressure, a major modifiable risk factor for glaucoma, has been shown to fluctuate throughout the day in patients with glaucoma. The detection and measurement of this fluctuation may help guide the clinical management of glaucomatous individuals. The Sensimed Triggerfish contact lens sensor (CLS), which has recently gained approval for marketing in the USA, is designed to detect intraocular pressure-related changes in an eye over a 24-hour period. This review will provide an overview of the Triggerfish CLS, as well as summarize current clinical data pertaining to the device. Overall, the current evidence suggests that the Triggerfish CLS is safe and well tolerated, and provides reproducible results. One challenge of using the Triggerfish CLS is that it may only provide data on relative changes in intraocular pressure rather than absolute intraocular pressure. In addition, its validity at estimating intraocular pressure compared to other methods is still controversial. Despite these limitations, recent studies suggest a myriad of potential indications for the Triggerfish CLS, including predicting glaucomatous progression and predicting efficacy of glaucoma treatment. With further research, the Triggerfish CLS may become a useful tool for eye care practitioners. Keywords: glaucoma, intraocular pressure, contact lens sensor, triggerfish CLS, Sensimed, 24-hour intraocular pressure monitoring |
format |
article |
author |
Dunbar GE Shen BY Aref AA |
author_facet |
Dunbar GE Shen BY Aref AA |
author_sort |
Dunbar GE |
title |
The Sensimed Triggerfish contact lens sensor: efficacy, safety, and patient perspectives |
title_short |
The Sensimed Triggerfish contact lens sensor: efficacy, safety, and patient perspectives |
title_full |
The Sensimed Triggerfish contact lens sensor: efficacy, safety, and patient perspectives |
title_fullStr |
The Sensimed Triggerfish contact lens sensor: efficacy, safety, and patient perspectives |
title_full_unstemmed |
The Sensimed Triggerfish contact lens sensor: efficacy, safety, and patient perspectives |
title_sort |
sensimed triggerfish contact lens sensor: efficacy, safety, and patient perspectives |
publisher |
Dove Medical Press |
publishDate |
2017 |
url |
https://doaj.org/article/8b3d65f8e68f406c828dbbbe041a1439 |
work_keys_str_mv |
AT dunbarge thesensimedtriggerfishcontactlenssensorefficacysafetyandpatientperspectives AT shenby thesensimedtriggerfishcontactlenssensorefficacysafetyandpatientperspectives AT arefaa thesensimedtriggerfishcontactlenssensorefficacysafetyandpatientperspectives AT dunbarge sensimedtriggerfishcontactlenssensorefficacysafetyandpatientperspectives AT shenby sensimedtriggerfishcontactlenssensorefficacysafetyandpatientperspectives AT arefaa sensimedtriggerfishcontactlenssensorefficacysafetyandpatientperspectives |
_version_ |
1718400063748702208 |