Addition Of D-Sorbitol Improves The Usability Of Ophthalmic Viscosurgical Devices

Ippei Watanabe,1 Mayumi Nagata,2 Hiroyuki Matsushima2 1Medical Science Liaison Unit, Seikagaku Corporation, Tokyo, Japan; 2Department of Ophthalmology, Dokkyo Medical University, Tochigi, JapanCorrespondence: Ippei WatanabeMedical Science Liaison Unit, Seikagaku Corp., 6-1, Marunouchi 1-chome, Chiyo...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Watanabe I, Nagata M, Matsushima H
Formato: article
Lenguaje:EN
Publicado: Dove Medical Press 2019
Materias:
Acceso en línea:https://doaj.org/article/8ba68f13cfbf4636ab66b3d7dde4fb0f
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:8ba68f13cfbf4636ab66b3d7dde4fb0f
record_format dspace
spelling oai:doaj.org-article:8ba68f13cfbf4636ab66b3d7dde4fb0f2021-12-02T05:14:20ZAddition Of D-Sorbitol Improves The Usability Of Ophthalmic Viscosurgical Devices1177-5483https://doaj.org/article/8ba68f13cfbf4636ab66b3d7dde4fb0f2019-09-01T00:00:00Zhttps://www.dovepress.com/addition-of-d-sorbitol-improves-the-usability-of-ophthalmic-viscosurgi-peer-reviewed-article-OPTHhttps://doaj.org/toc/1177-5483Ippei Watanabe,1 Mayumi Nagata,2 Hiroyuki Matsushima2 1Medical Science Liaison Unit, Seikagaku Corporation, Tokyo, Japan; 2Department of Ophthalmology, Dokkyo Medical University, Tochigi, JapanCorrespondence: Ippei WatanabeMedical Science Liaison Unit, Seikagaku Corp., 6-1, Marunouchi 1-chome, Chiyoda-ku, Tokyo 100-0005, JapanTel +81 3 352208595Fax +81 3 352208975Email ippei.watanabe@seikagaku.co.jpPurpose: To evaluate the effects of D-sorbitol addition on changes in the extrusion force of ophthalmic viscosurgical devices (OVDs).Methods: OVD formulations; the mixtures of 3% hyaluronic acid (HA) and 4% chondroitin sulfate (CS) containing 0%, 0.5%, or 1.0% D-sorbitol were prepared. Each prefilled syringe of OVD was stored at room temperature for 0, 15, 30, 60, or 120 mins after a small amount of viscoelastic agent was discharged from the needle. The extrusion force values (kgf) of these OVDs when reused after storage were measured with a texture analyzer. Moreover, 10 healthy adults (5 men and 5 women) used a pinch sensor to measure the extrusion force values for the HA/CS combination without D-sorbitol which was stored in the above manner, and used a 4-step scale to score the usability of OVD.Results: For the HA/CS combination without D-sorbitol, the extrusion force value was increased from its initial value (storage duration, 0 min) as storage duration increased. However, for the HA/CS combination containing 0.5% or 1.0% D-sorbitol, this value remained almost unchanged over time. Likewise, the pinch sensor-determined extrusion force values of HA/CS combination without D-sorbitol increased, depending on storage duration.Conclusion: The addition of D-sorbitol to viscoelastic agent may suppress the needle clogging that occurs with OVD storage, and may improve the usability of OVDs during surgery.Keywords: ophthalmic viscosurgical device, extrusion force, cataract surgery, vitreous surgeryWatanabe INagata MMatsushima HDove Medical Pressarticleophthalmic viscosurgical deviceextrusion forcecataract surgeryvitreous surgeryOphthalmologyRE1-994ENClinical Ophthalmology, Vol Volume 13, Pp 1877-1885 (2019)
institution DOAJ
collection DOAJ
language EN
topic ophthalmic viscosurgical device
extrusion force
cataract surgery
vitreous surgery
Ophthalmology
RE1-994
spellingShingle ophthalmic viscosurgical device
extrusion force
cataract surgery
vitreous surgery
Ophthalmology
RE1-994
Watanabe I
Nagata M
Matsushima H
Addition Of D-Sorbitol Improves The Usability Of Ophthalmic Viscosurgical Devices
description Ippei Watanabe,1 Mayumi Nagata,2 Hiroyuki Matsushima2 1Medical Science Liaison Unit, Seikagaku Corporation, Tokyo, Japan; 2Department of Ophthalmology, Dokkyo Medical University, Tochigi, JapanCorrespondence: Ippei WatanabeMedical Science Liaison Unit, Seikagaku Corp., 6-1, Marunouchi 1-chome, Chiyoda-ku, Tokyo 100-0005, JapanTel +81 3 352208595Fax +81 3 352208975Email ippei.watanabe@seikagaku.co.jpPurpose: To evaluate the effects of D-sorbitol addition on changes in the extrusion force of ophthalmic viscosurgical devices (OVDs).Methods: OVD formulations; the mixtures of 3% hyaluronic acid (HA) and 4% chondroitin sulfate (CS) containing 0%, 0.5%, or 1.0% D-sorbitol were prepared. Each prefilled syringe of OVD was stored at room temperature for 0, 15, 30, 60, or 120 mins after a small amount of viscoelastic agent was discharged from the needle. The extrusion force values (kgf) of these OVDs when reused after storage were measured with a texture analyzer. Moreover, 10 healthy adults (5 men and 5 women) used a pinch sensor to measure the extrusion force values for the HA/CS combination without D-sorbitol which was stored in the above manner, and used a 4-step scale to score the usability of OVD.Results: For the HA/CS combination without D-sorbitol, the extrusion force value was increased from its initial value (storage duration, 0 min) as storage duration increased. However, for the HA/CS combination containing 0.5% or 1.0% D-sorbitol, this value remained almost unchanged over time. Likewise, the pinch sensor-determined extrusion force values of HA/CS combination without D-sorbitol increased, depending on storage duration.Conclusion: The addition of D-sorbitol to viscoelastic agent may suppress the needle clogging that occurs with OVD storage, and may improve the usability of OVDs during surgery.Keywords: ophthalmic viscosurgical device, extrusion force, cataract surgery, vitreous surgery
format article
author Watanabe I
Nagata M
Matsushima H
author_facet Watanabe I
Nagata M
Matsushima H
author_sort Watanabe I
title Addition Of D-Sorbitol Improves The Usability Of Ophthalmic Viscosurgical Devices
title_short Addition Of D-Sorbitol Improves The Usability Of Ophthalmic Viscosurgical Devices
title_full Addition Of D-Sorbitol Improves The Usability Of Ophthalmic Viscosurgical Devices
title_fullStr Addition Of D-Sorbitol Improves The Usability Of Ophthalmic Viscosurgical Devices
title_full_unstemmed Addition Of D-Sorbitol Improves The Usability Of Ophthalmic Viscosurgical Devices
title_sort addition of d-sorbitol improves the usability of ophthalmic viscosurgical devices
publisher Dove Medical Press
publishDate 2019
url https://doaj.org/article/8ba68f13cfbf4636ab66b3d7dde4fb0f
work_keys_str_mv AT watanabei additionofdsorbitolimprovestheusabilityofophthalmicviscosurgicaldevices
AT nagatam additionofdsorbitolimprovestheusabilityofophthalmicviscosurgicaldevices
AT matsushimah additionofdsorbitolimprovestheusabilityofophthalmicviscosurgicaldevices
_version_ 1718400482359115776