Addition Of D-Sorbitol Improves The Usability Of Ophthalmic Viscosurgical Devices
Ippei Watanabe,1 Mayumi Nagata,2 Hiroyuki Matsushima2 1Medical Science Liaison Unit, Seikagaku Corporation, Tokyo, Japan; 2Department of Ophthalmology, Dokkyo Medical University, Tochigi, JapanCorrespondence: Ippei WatanabeMedical Science Liaison Unit, Seikagaku Corp., 6-1, Marunouchi 1-chome, Chiyo...
Guardado en:
Autores principales: | , , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
Dove Medical Press
2019
|
Materias: | |
Acceso en línea: | https://doaj.org/article/8ba68f13cfbf4636ab66b3d7dde4fb0f |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:8ba68f13cfbf4636ab66b3d7dde4fb0f |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:8ba68f13cfbf4636ab66b3d7dde4fb0f2021-12-02T05:14:20ZAddition Of D-Sorbitol Improves The Usability Of Ophthalmic Viscosurgical Devices1177-5483https://doaj.org/article/8ba68f13cfbf4636ab66b3d7dde4fb0f2019-09-01T00:00:00Zhttps://www.dovepress.com/addition-of-d-sorbitol-improves-the-usability-of-ophthalmic-viscosurgi-peer-reviewed-article-OPTHhttps://doaj.org/toc/1177-5483Ippei Watanabe,1 Mayumi Nagata,2 Hiroyuki Matsushima2 1Medical Science Liaison Unit, Seikagaku Corporation, Tokyo, Japan; 2Department of Ophthalmology, Dokkyo Medical University, Tochigi, JapanCorrespondence: Ippei WatanabeMedical Science Liaison Unit, Seikagaku Corp., 6-1, Marunouchi 1-chome, Chiyoda-ku, Tokyo 100-0005, JapanTel +81 3 352208595Fax +81 3 352208975Email ippei.watanabe@seikagaku.co.jpPurpose: To evaluate the effects of D-sorbitol addition on changes in the extrusion force of ophthalmic viscosurgical devices (OVDs).Methods: OVD formulations; the mixtures of 3% hyaluronic acid (HA) and 4% chondroitin sulfate (CS) containing 0%, 0.5%, or 1.0% D-sorbitol were prepared. Each prefilled syringe of OVD was stored at room temperature for 0, 15, 30, 60, or 120 mins after a small amount of viscoelastic agent was discharged from the needle. The extrusion force values (kgf) of these OVDs when reused after storage were measured with a texture analyzer. Moreover, 10 healthy adults (5 men and 5 women) used a pinch sensor to measure the extrusion force values for the HA/CS combination without D-sorbitol which was stored in the above manner, and used a 4-step scale to score the usability of OVD.Results: For the HA/CS combination without D-sorbitol, the extrusion force value was increased from its initial value (storage duration, 0 min) as storage duration increased. However, for the HA/CS combination containing 0.5% or 1.0% D-sorbitol, this value remained almost unchanged over time. Likewise, the pinch sensor-determined extrusion force values of HA/CS combination without D-sorbitol increased, depending on storage duration.Conclusion: The addition of D-sorbitol to viscoelastic agent may suppress the needle clogging that occurs with OVD storage, and may improve the usability of OVDs during surgery.Keywords: ophthalmic viscosurgical device, extrusion force, cataract surgery, vitreous surgeryWatanabe INagata MMatsushima HDove Medical Pressarticleophthalmic viscosurgical deviceextrusion forcecataract surgeryvitreous surgeryOphthalmologyRE1-994ENClinical Ophthalmology, Vol Volume 13, Pp 1877-1885 (2019) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
ophthalmic viscosurgical device extrusion force cataract surgery vitreous surgery Ophthalmology RE1-994 |
spellingShingle |
ophthalmic viscosurgical device extrusion force cataract surgery vitreous surgery Ophthalmology RE1-994 Watanabe I Nagata M Matsushima H Addition Of D-Sorbitol Improves The Usability Of Ophthalmic Viscosurgical Devices |
description |
Ippei Watanabe,1 Mayumi Nagata,2 Hiroyuki Matsushima2 1Medical Science Liaison Unit, Seikagaku Corporation, Tokyo, Japan; 2Department of Ophthalmology, Dokkyo Medical University, Tochigi, JapanCorrespondence: Ippei WatanabeMedical Science Liaison Unit, Seikagaku Corp., 6-1, Marunouchi 1-chome, Chiyoda-ku, Tokyo 100-0005, JapanTel +81 3 352208595Fax +81 3 352208975Email ippei.watanabe@seikagaku.co.jpPurpose: To evaluate the effects of D-sorbitol addition on changes in the extrusion force of ophthalmic viscosurgical devices (OVDs).Methods: OVD formulations; the mixtures of 3% hyaluronic acid (HA) and 4% chondroitin sulfate (CS) containing 0%, 0.5%, or 1.0% D-sorbitol were prepared. Each prefilled syringe of OVD was stored at room temperature for 0, 15, 30, 60, or 120 mins after a small amount of viscoelastic agent was discharged from the needle. The extrusion force values (kgf) of these OVDs when reused after storage were measured with a texture analyzer. Moreover, 10 healthy adults (5 men and 5 women) used a pinch sensor to measure the extrusion force values for the HA/CS combination without D-sorbitol which was stored in the above manner, and used a 4-step scale to score the usability of OVD.Results: For the HA/CS combination without D-sorbitol, the extrusion force value was increased from its initial value (storage duration, 0 min) as storage duration increased. However, for the HA/CS combination containing 0.5% or 1.0% D-sorbitol, this value remained almost unchanged over time. Likewise, the pinch sensor-determined extrusion force values of HA/CS combination without D-sorbitol increased, depending on storage duration.Conclusion: The addition of D-sorbitol to viscoelastic agent may suppress the needle clogging that occurs with OVD storage, and may improve the usability of OVDs during surgery.Keywords: ophthalmic viscosurgical device, extrusion force, cataract surgery, vitreous surgery |
format |
article |
author |
Watanabe I Nagata M Matsushima H |
author_facet |
Watanabe I Nagata M Matsushima H |
author_sort |
Watanabe I |
title |
Addition Of D-Sorbitol Improves The Usability Of Ophthalmic Viscosurgical Devices |
title_short |
Addition Of D-Sorbitol Improves The Usability Of Ophthalmic Viscosurgical Devices |
title_full |
Addition Of D-Sorbitol Improves The Usability Of Ophthalmic Viscosurgical Devices |
title_fullStr |
Addition Of D-Sorbitol Improves The Usability Of Ophthalmic Viscosurgical Devices |
title_full_unstemmed |
Addition Of D-Sorbitol Improves The Usability Of Ophthalmic Viscosurgical Devices |
title_sort |
addition of d-sorbitol improves the usability of ophthalmic viscosurgical devices |
publisher |
Dove Medical Press |
publishDate |
2019 |
url |
https://doaj.org/article/8ba68f13cfbf4636ab66b3d7dde4fb0f |
work_keys_str_mv |
AT watanabei additionofdsorbitolimprovestheusabilityofophthalmicviscosurgicaldevices AT nagatam additionofdsorbitolimprovestheusabilityofophthalmicviscosurgicaldevices AT matsushimah additionofdsorbitolimprovestheusabilityofophthalmicviscosurgicaldevices |
_version_ |
1718400482359115776 |