Comparison between R134a and R1234ze(E) during Flow Boiling in Microfin Tubes
Environmental concerns are forcing the replacement of commonly used refrigerants, and finding new fluids is a top priority. Soon the R134a will be banned, and the hydro-fluoro-olefin (HFO) R1234ze(E) has been indicated as an alternative due to its smaller global warming potential (GWP) and shorter a...
Guardado en:
Autores principales: | Andrea Lucchini, Igor M. Carraretto, Thanh N. Phan, Paola G. Pittoni, Luigi P. M. Colombo |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
MDPI AG
2021
|
Materias: | |
Acceso en línea: | https://doaj.org/article/8c02e9a1f990437b9fbca7b2500f301c |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
Ejemplares similares
-
Study of CO2 solubility in bicyclic ionic liquids by thermodynamic properties and FT-IR spectroscopic analysis at T=(303.15 and 313.15) K
por: Venkatramana Losetty, et al.
Publicado: (2021) -
Methane hydrate thermodynamic phase stability predictions in the presence of salt inhibitors and their mixture for offshore operations
por: Venkata Ramana Avula, et al.
Publicado: (2021) -
Vapor pressure and thermophysical properties of explosive taggants
por: Vojtěch Štejfa, et al.
Publicado: (2021) -
Effect of Surfactant Concentration on the Long-Term Properties of a Colloidal Chemical, Biological and Radiological (CBR) Decontamination Gel
por: Alban Gossard, et al.
Publicado: (2021) -
Mantle Electrical Conductivity and the Magnetic Field at the Core–Mantle Boundary
por: John V. Shebalin
Publicado: (2021)