A Modified Technique of Bipolar Loop Resectoscopic Slicing for Treating Submucous Fibroids With Enucleation Makes the Operation Safer

Background: In this study, a modified technique of resectoscopic slicing with a common bipolar loop was introduced, which facilitated the complete removal of the submucous fibroid inside the uterine cavity without any novel equipment.Results: Compared with the classical technique, our modified proce...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Wenying Zhang, Jing Liu, Qiongwei Wu, Yu Liu, Chunchun Wang, Chengbin Ma
Formato: article
Lenguaje:EN
Publicado: Frontiers Media S.A. 2021
Materias:
Acceso en línea:https://doaj.org/article/8c546e7daf0e4fafbed2c554c04a26b3
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
Descripción
Sumario:Background: In this study, a modified technique of resectoscopic slicing with a common bipolar loop was introduced, which facilitated the complete removal of the submucous fibroid inside the uterine cavity without any novel equipment.Results: Compared with the classical technique, our modified procedure possessed a shorter operation time (22.9 ± 7.3 vs. 38.9 ± 13.0 min, p < 0.05) and a smaller distending media volume (1,495.6 ± 540.1 vs. 2,393.1 ± 719.4 ml, p < 0.01).Conclusion: As a result, the current study suggested that the enucleation of submucous fibroid under hysteroscopy could be achieved by using only the bipolar loop, which reduced the consumption for novel equipment and enhanced the safety of the technique.