A Modified Technique of Bipolar Loop Resectoscopic Slicing for Treating Submucous Fibroids With Enucleation Makes the Operation Safer
Background: In this study, a modified technique of resectoscopic slicing with a common bipolar loop was introduced, which facilitated the complete removal of the submucous fibroid inside the uterine cavity without any novel equipment.Results: Compared with the classical technique, our modified proce...
Guardado en:
Autores principales: | , , , , , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
Frontiers Media S.A.
2021
|
Materias: | |
Acceso en línea: | https://doaj.org/article/8c546e7daf0e4fafbed2c554c04a26b3 |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:8c546e7daf0e4fafbed2c554c04a26b3 |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:8c546e7daf0e4fafbed2c554c04a26b32021-11-10T05:58:28ZA Modified Technique of Bipolar Loop Resectoscopic Slicing for Treating Submucous Fibroids With Enucleation Makes the Operation Safer2296-875X10.3389/fsurg.2021.746936https://doaj.org/article/8c546e7daf0e4fafbed2c554c04a26b32021-11-01T00:00:00Zhttps://www.frontiersin.org/articles/10.3389/fsurg.2021.746936/fullhttps://doaj.org/toc/2296-875XBackground: In this study, a modified technique of resectoscopic slicing with a common bipolar loop was introduced, which facilitated the complete removal of the submucous fibroid inside the uterine cavity without any novel equipment.Results: Compared with the classical technique, our modified procedure possessed a shorter operation time (22.9 ± 7.3 vs. 38.9 ± 13.0 min, p < 0.05) and a smaller distending media volume (1,495.6 ± 540.1 vs. 2,393.1 ± 719.4 ml, p < 0.01).Conclusion: As a result, the current study suggested that the enucleation of submucous fibroid under hysteroscopy could be achieved by using only the bipolar loop, which reduced the consumption for novel equipment and enhanced the safety of the technique.Wenying ZhangJing LiuQiongwei WuYu LiuChunchun WangChengbin MaFrontiers Media S.A.articlebipolar loopenucleationhysteroscopymodified techniquesubmucous fibroidSurgeryRD1-811ENFrontiers in Surgery, Vol 8 (2021) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
bipolar loop enucleation hysteroscopy modified technique submucous fibroid Surgery RD1-811 |
spellingShingle |
bipolar loop enucleation hysteroscopy modified technique submucous fibroid Surgery RD1-811 Wenying Zhang Jing Liu Qiongwei Wu Yu Liu Chunchun Wang Chengbin Ma A Modified Technique of Bipolar Loop Resectoscopic Slicing for Treating Submucous Fibroids With Enucleation Makes the Operation Safer |
description |
Background: In this study, a modified technique of resectoscopic slicing with a common bipolar loop was introduced, which facilitated the complete removal of the submucous fibroid inside the uterine cavity without any novel equipment.Results: Compared with the classical technique, our modified procedure possessed a shorter operation time (22.9 ± 7.3 vs. 38.9 ± 13.0 min, p < 0.05) and a smaller distending media volume (1,495.6 ± 540.1 vs. 2,393.1 ± 719.4 ml, p < 0.01).Conclusion: As a result, the current study suggested that the enucleation of submucous fibroid under hysteroscopy could be achieved by using only the bipolar loop, which reduced the consumption for novel equipment and enhanced the safety of the technique. |
format |
article |
author |
Wenying Zhang Jing Liu Qiongwei Wu Yu Liu Chunchun Wang Chengbin Ma |
author_facet |
Wenying Zhang Jing Liu Qiongwei Wu Yu Liu Chunchun Wang Chengbin Ma |
author_sort |
Wenying Zhang |
title |
A Modified Technique of Bipolar Loop Resectoscopic Slicing for Treating Submucous Fibroids With Enucleation Makes the Operation Safer |
title_short |
A Modified Technique of Bipolar Loop Resectoscopic Slicing for Treating Submucous Fibroids With Enucleation Makes the Operation Safer |
title_full |
A Modified Technique of Bipolar Loop Resectoscopic Slicing for Treating Submucous Fibroids With Enucleation Makes the Operation Safer |
title_fullStr |
A Modified Technique of Bipolar Loop Resectoscopic Slicing for Treating Submucous Fibroids With Enucleation Makes the Operation Safer |
title_full_unstemmed |
A Modified Technique of Bipolar Loop Resectoscopic Slicing for Treating Submucous Fibroids With Enucleation Makes the Operation Safer |
title_sort |
modified technique of bipolar loop resectoscopic slicing for treating submucous fibroids with enucleation makes the operation safer |
publisher |
Frontiers Media S.A. |
publishDate |
2021 |
url |
https://doaj.org/article/8c546e7daf0e4fafbed2c554c04a26b3 |
work_keys_str_mv |
AT wenyingzhang amodifiedtechniqueofbipolarloopresectoscopicslicingfortreatingsubmucousfibroidswithenucleationmakestheoperationsafer AT jingliu amodifiedtechniqueofbipolarloopresectoscopicslicingfortreatingsubmucousfibroidswithenucleationmakestheoperationsafer AT qiongweiwu amodifiedtechniqueofbipolarloopresectoscopicslicingfortreatingsubmucousfibroidswithenucleationmakestheoperationsafer AT yuliu amodifiedtechniqueofbipolarloopresectoscopicslicingfortreatingsubmucousfibroidswithenucleationmakestheoperationsafer AT chunchunwang amodifiedtechniqueofbipolarloopresectoscopicslicingfortreatingsubmucousfibroidswithenucleationmakestheoperationsafer AT chengbinma amodifiedtechniqueofbipolarloopresectoscopicslicingfortreatingsubmucousfibroidswithenucleationmakestheoperationsafer AT wenyingzhang modifiedtechniqueofbipolarloopresectoscopicslicingfortreatingsubmucousfibroidswithenucleationmakestheoperationsafer AT jingliu modifiedtechniqueofbipolarloopresectoscopicslicingfortreatingsubmucousfibroidswithenucleationmakestheoperationsafer AT qiongweiwu modifiedtechniqueofbipolarloopresectoscopicslicingfortreatingsubmucousfibroidswithenucleationmakestheoperationsafer AT yuliu modifiedtechniqueofbipolarloopresectoscopicslicingfortreatingsubmucousfibroidswithenucleationmakestheoperationsafer AT chunchunwang modifiedtechniqueofbipolarloopresectoscopicslicingfortreatingsubmucousfibroidswithenucleationmakestheoperationsafer AT chengbinma modifiedtechniqueofbipolarloopresectoscopicslicingfortreatingsubmucousfibroidswithenucleationmakestheoperationsafer |
_version_ |
1718440486780272640 |