Magnetic-nanoparticles-based fluorescent immunoassay for individual and simultaneous determination of dichlorvos and paraoxon in milk

A sensitive and rapid magnetic-nanoparticles-based fluorescent immunoassay (MNPs-FIA) for individual and simultaneous determination of dichlorvos (DDVP) and paraoxon in untreated raw milk was developed. The conjugates DDVP–cBSA (cationized bovine serum albumin) and paraoxon–BSA (bovine serum albumin...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Marina Yaneva, Yavor Ivanov, Nikola Todorov, Tzonka Godjevargova
Formato: article
Lenguaje:EN
Publicado: Taylor & Francis Group 2018
Materias:
Acceso en línea:https://doaj.org/article/8cb743bae03649ba8f774f34862a4972
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:8cb743bae03649ba8f774f34862a4972
record_format dspace
spelling oai:doaj.org-article:8cb743bae03649ba8f774f34862a49722021-11-26T11:19:46ZMagnetic-nanoparticles-based fluorescent immunoassay for individual and simultaneous determination of dichlorvos and paraoxon in milk0954-01051465-344310.1080/09540105.2017.1368458https://doaj.org/article/8cb743bae03649ba8f774f34862a49722018-01-01T00:00:00Zhttp://dx.doi.org/10.1080/09540105.2017.1368458https://doaj.org/toc/0954-0105https://doaj.org/toc/1465-3443A sensitive and rapid magnetic-nanoparticles-based fluorescent immunoassay (MNPs-FIA) for individual and simultaneous determination of dichlorvos (DDVP) and paraoxon in untreated raw milk was developed. The conjugates DDVP–cBSA (cationized bovine serum albumin) and paraoxon–BSA (bovine serum albumin) were labeled by fluorescent dyes. The optimal amount of immobilized polyclonal anti-DDVP and anti-paraoxon antibodies on MNPs (0.375 mg Ab-MNPs) and optimal concentrations of DDVP–cBSA–FITC (18 µg/mL) and paraoxon–BSA–FITC (22 µg/mL) for MNPs-FIA were determined. The calibration curves of individual and simultaneous immunoassays of DDVP and paraoxon were investigated. The IC50 value of the individual paraoxon assay in raw cow’s milk was 60 ng/mL and linear range 2–300 ng/mL. The IC50 value of the individual DDVP assay was 70 ng/mL and linear range 5–300 ng/mL. The IC50 values of the paraoxon and DDVP (100 and 120 ng/mL respectively) in simultaneous assay were higher than those of the individual ones, and their linear ranges were 10–400 ng/mL.Marina YanevaYavor IvanovNikola TodorovTzonka GodjevargovaTaylor & Francis Grouparticleparaoxоndichlorvosmilkimmunoassayfluorescencemagnetic nanoparticlesAgriculture (General)S1-972Immunologic diseases. AllergyRC581-607ENFood and Agricultural Immunology, Vol 29, Iss 1, Pp 228-243 (2018)
institution DOAJ
collection DOAJ
language EN
topic paraoxоn
dichlorvos
milk
immunoassay
fluorescence
magnetic nanoparticles
Agriculture (General)
S1-972
Immunologic diseases. Allergy
RC581-607
spellingShingle paraoxоn
dichlorvos
milk
immunoassay
fluorescence
magnetic nanoparticles
Agriculture (General)
S1-972
Immunologic diseases. Allergy
RC581-607
Marina Yaneva
Yavor Ivanov
Nikola Todorov
Tzonka Godjevargova
Magnetic-nanoparticles-based fluorescent immunoassay for individual and simultaneous determination of dichlorvos and paraoxon in milk
description A sensitive and rapid magnetic-nanoparticles-based fluorescent immunoassay (MNPs-FIA) for individual and simultaneous determination of dichlorvos (DDVP) and paraoxon in untreated raw milk was developed. The conjugates DDVP–cBSA (cationized bovine serum albumin) and paraoxon–BSA (bovine serum albumin) were labeled by fluorescent dyes. The optimal amount of immobilized polyclonal anti-DDVP and anti-paraoxon antibodies on MNPs (0.375 mg Ab-MNPs) and optimal concentrations of DDVP–cBSA–FITC (18 µg/mL) and paraoxon–BSA–FITC (22 µg/mL) for MNPs-FIA were determined. The calibration curves of individual and simultaneous immunoassays of DDVP and paraoxon were investigated. The IC50 value of the individual paraoxon assay in raw cow’s milk was 60 ng/mL and linear range 2–300 ng/mL. The IC50 value of the individual DDVP assay was 70 ng/mL and linear range 5–300 ng/mL. The IC50 values of the paraoxon and DDVP (100 and 120 ng/mL respectively) in simultaneous assay were higher than those of the individual ones, and their linear ranges were 10–400 ng/mL.
format article
author Marina Yaneva
Yavor Ivanov
Nikola Todorov
Tzonka Godjevargova
author_facet Marina Yaneva
Yavor Ivanov
Nikola Todorov
Tzonka Godjevargova
author_sort Marina Yaneva
title Magnetic-nanoparticles-based fluorescent immunoassay for individual and simultaneous determination of dichlorvos and paraoxon in milk
title_short Magnetic-nanoparticles-based fluorescent immunoassay for individual and simultaneous determination of dichlorvos and paraoxon in milk
title_full Magnetic-nanoparticles-based fluorescent immunoassay for individual and simultaneous determination of dichlorvos and paraoxon in milk
title_fullStr Magnetic-nanoparticles-based fluorescent immunoassay for individual and simultaneous determination of dichlorvos and paraoxon in milk
title_full_unstemmed Magnetic-nanoparticles-based fluorescent immunoassay for individual and simultaneous determination of dichlorvos and paraoxon in milk
title_sort magnetic-nanoparticles-based fluorescent immunoassay for individual and simultaneous determination of dichlorvos and paraoxon in milk
publisher Taylor & Francis Group
publishDate 2018
url https://doaj.org/article/8cb743bae03649ba8f774f34862a4972
work_keys_str_mv AT marinayaneva magneticnanoparticlesbasedfluorescentimmunoassayforindividualandsimultaneousdeterminationofdichlorvosandparaoxoninmilk
AT yavorivanov magneticnanoparticlesbasedfluorescentimmunoassayforindividualandsimultaneousdeterminationofdichlorvosandparaoxoninmilk
AT nikolatodorov magneticnanoparticlesbasedfluorescentimmunoassayforindividualandsimultaneousdeterminationofdichlorvosandparaoxoninmilk
AT tzonkagodjevargova magneticnanoparticlesbasedfluorescentimmunoassayforindividualandsimultaneousdeterminationofdichlorvosandparaoxoninmilk
_version_ 1718409547178049536