A simple method to minimize leg length discrepancy in hip hemiarthroplasty
Guodong Wang,1,2 Ai Guo,1 Fei Yu,1 Bo Yang,1 Haomiao Yu,1 Naicheng Diao,1 Lifeng Ma,1 Hua Qiang,2 Erhong Zhao2 1Department of Orthopaedics, Beijing Friendship Hospital, Capital Medical University, Beijing 100050, People&rsqu...
Guardado en:
Autores principales: | , , , , , , , , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
Dove Medical Press
2019
|
Materias: | |
Acceso en línea: | https://doaj.org/article/8d33763dfb5145aaafb78116685d74a3 |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:8d33763dfb5145aaafb78116685d74a3 |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:8d33763dfb5145aaafb78116685d74a32021-12-02T07:23:45ZA simple method to minimize leg length discrepancy in hip hemiarthroplasty1178-1998https://doaj.org/article/8d33763dfb5145aaafb78116685d74a32019-09-01T00:00:00Zhttps://www.dovepress.com/a-simple-method-to-minimize-leg-length-discrepancy-in-hip-hemiarthropl-peer-reviewed-article-CIAhttps://doaj.org/toc/1178-1998Guodong Wang,1,2 Ai Guo,1 Fei Yu,1 Bo Yang,1 Haomiao Yu,1 Naicheng Diao,1 Lifeng Ma,1 Hua Qiang,2 Erhong Zhao2 1Department of Orthopaedics, Beijing Friendship Hospital, Capital Medical University, Beijing 100050, People’s Republic of China; 2Department of Orthopaedics, Beijing Tongren Hospital, Capital Medical University, Beijing 100730, People’s Republic of ChinaCorrespondence: Ai GuoDepartment of Orthopaedics, Beijing Friendship Hospital, Capital Medical University, No 95, YongAn Road, Xicheng District, Beijing 100050, People’s Republic of ChinaTel +86 106 313 8293Email guoaij@139.comPurpose: We developed a simple method to minimize leg length discrepancy (LLD) during hip arthroplasty. The purpose of this study is to evaluate the accuracy of the method.Patients and methods: A total of 47 patients who suffered from unilateral femoral neck fracture and underwent hip hemiarthroplasty between 2015 and 2018 were enrolled in this study. We measured the diameter of the contralateral femoral head (D) and the distance (L) between the center of the femoral head and the top of lesser trochanter in the antero-posterior pelvic X-ray view before the operation, the ratio (R) of D to L was calculated. During the operation, the diameter of the femoral head (d) was measured using a Vernier caliper. Then, the distance should be obtained from the center of the femoral head prosthesis to the lesser trochanter was calculated according to the contralateral ratio R.Results: The mean LLD was 4.4±3.2 mm (−4.0 to 11.1 mm), 80.9% of the patients had LLD <6 mm, 93.6% of the patients with LLD <10 mm, only 6.4% ≥10 mm LLD.Conclusion: This method is a simple, cost-effective, fast and accurate way to reduce the postoperative leg length discrepancy.Keywords: leg length discrepancy, hip arthroplasty, femoral neck fracture, contralateral side, measurement Wang GGuo AYu FYang BYu HDiao NMa LQiang HZhao EDove Medical PressarticleLeg length discrepancyHip ArthroplastyFemoral neck fractureContralateral sideMeasurementGeriatricsRC952-954.6ENClinical Interventions in Aging, Vol Volume 14, Pp 1601-1605 (2019) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
Leg length discrepancy Hip Arthroplasty Femoral neck fracture Contralateral side Measurement Geriatrics RC952-954.6 |
spellingShingle |
Leg length discrepancy Hip Arthroplasty Femoral neck fracture Contralateral side Measurement Geriatrics RC952-954.6 Wang G Guo A Yu F Yang B Yu H Diao N Ma L Qiang H Zhao E A simple method to minimize leg length discrepancy in hip hemiarthroplasty |
description |
Guodong Wang,1,2 Ai Guo,1 Fei Yu,1 Bo Yang,1 Haomiao Yu,1 Naicheng Diao,1 Lifeng Ma,1 Hua Qiang,2 Erhong Zhao2 1Department of Orthopaedics, Beijing Friendship Hospital, Capital Medical University, Beijing 100050, People’s Republic of China; 2Department of Orthopaedics, Beijing Tongren Hospital, Capital Medical University, Beijing 100730, People’s Republic of ChinaCorrespondence: Ai GuoDepartment of Orthopaedics, Beijing Friendship Hospital, Capital Medical University, No 95, YongAn Road, Xicheng District, Beijing 100050, People’s Republic of ChinaTel +86 106 313 8293Email guoaij@139.comPurpose: We developed a simple method to minimize leg length discrepancy (LLD) during hip arthroplasty. The purpose of this study is to evaluate the accuracy of the method.Patients and methods: A total of 47 patients who suffered from unilateral femoral neck fracture and underwent hip hemiarthroplasty between 2015 and 2018 were enrolled in this study. We measured the diameter of the contralateral femoral head (D) and the distance (L) between the center of the femoral head and the top of lesser trochanter in the antero-posterior pelvic X-ray view before the operation, the ratio (R) of D to L was calculated. During the operation, the diameter of the femoral head (d) was measured using a Vernier caliper. Then, the distance should be obtained from the center of the femoral head prosthesis to the lesser trochanter was calculated according to the contralateral ratio R.Results: The mean LLD was 4.4±3.2 mm (−4.0 to 11.1 mm), 80.9% of the patients had LLD <6 mm, 93.6% of the patients with LLD <10 mm, only 6.4% ≥10 mm LLD.Conclusion: This method is a simple, cost-effective, fast and accurate way to reduce the postoperative leg length discrepancy.Keywords: leg length discrepancy, hip arthroplasty, femoral neck fracture, contralateral side, measurement
|
format |
article |
author |
Wang G Guo A Yu F Yang B Yu H Diao N Ma L Qiang H Zhao E |
author_facet |
Wang G Guo A Yu F Yang B Yu H Diao N Ma L Qiang H Zhao E |
author_sort |
Wang G |
title |
A simple method to minimize leg length discrepancy in hip hemiarthroplasty |
title_short |
A simple method to minimize leg length discrepancy in hip hemiarthroplasty |
title_full |
A simple method to minimize leg length discrepancy in hip hemiarthroplasty |
title_fullStr |
A simple method to minimize leg length discrepancy in hip hemiarthroplasty |
title_full_unstemmed |
A simple method to minimize leg length discrepancy in hip hemiarthroplasty |
title_sort |
simple method to minimize leg length discrepancy in hip hemiarthroplasty |
publisher |
Dove Medical Press |
publishDate |
2019 |
url |
https://doaj.org/article/8d33763dfb5145aaafb78116685d74a3 |
work_keys_str_mv |
AT wangg asimplemethodtominimizeleglengthdiscrepancyinhiphemiarthroplasty AT guoa asimplemethodtominimizeleglengthdiscrepancyinhiphemiarthroplasty AT yuf asimplemethodtominimizeleglengthdiscrepancyinhiphemiarthroplasty AT yangb asimplemethodtominimizeleglengthdiscrepancyinhiphemiarthroplasty AT yuh asimplemethodtominimizeleglengthdiscrepancyinhiphemiarthroplasty AT diaon asimplemethodtominimizeleglengthdiscrepancyinhiphemiarthroplasty AT mal asimplemethodtominimizeleglengthdiscrepancyinhiphemiarthroplasty AT qiangh asimplemethodtominimizeleglengthdiscrepancyinhiphemiarthroplasty AT zhaoe asimplemethodtominimizeleglengthdiscrepancyinhiphemiarthroplasty AT wangg simplemethodtominimizeleglengthdiscrepancyinhiphemiarthroplasty AT guoa simplemethodtominimizeleglengthdiscrepancyinhiphemiarthroplasty AT yuf simplemethodtominimizeleglengthdiscrepancyinhiphemiarthroplasty AT yangb simplemethodtominimizeleglengthdiscrepancyinhiphemiarthroplasty AT yuh simplemethodtominimizeleglengthdiscrepancyinhiphemiarthroplasty AT diaon simplemethodtominimizeleglengthdiscrepancyinhiphemiarthroplasty AT mal simplemethodtominimizeleglengthdiscrepancyinhiphemiarthroplasty AT qiangh simplemethodtominimizeleglengthdiscrepancyinhiphemiarthroplasty AT zhaoe simplemethodtominimizeleglengthdiscrepancyinhiphemiarthroplasty |
_version_ |
1718399465735323648 |