Experimental Determination of Parameters of Nonlinear Electrical Load

The paper deals with issues of modeling nonlinear electrical loads of various types, such an uncontrolled rectifier, thyristor rectifier, thyristor power regulator and mixed equivalent nonlinear load. For these load types, existing analytical expressions were identified to determine the magnitudes o...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Aleksandr Skamyin, Yaroslav Shklyarskiy, Vasiliy Dobush, Iuliia Dobush
Formato: article
Lenguaje:EN
Publicado: MDPI AG 2021
Materias:
T
Acceso en línea:https://doaj.org/article/8e96d2cfe3e049cbb72d7fc033d9e2b7
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:8e96d2cfe3e049cbb72d7fc033d9e2b7
record_format dspace
spelling oai:doaj.org-article:8e96d2cfe3e049cbb72d7fc033d9e2b72021-11-25T17:28:34ZExperimental Determination of Parameters of Nonlinear Electrical Load10.3390/en142277621996-1073https://doaj.org/article/8e96d2cfe3e049cbb72d7fc033d9e2b72021-11-01T00:00:00Zhttps://www.mdpi.com/1996-1073/14/22/7762https://doaj.org/toc/1996-1073The paper deals with issues of modeling nonlinear electrical loads of various types, such an uncontrolled rectifier, thyristor rectifier, thyristor power regulator and mixed equivalent nonlinear load. For these load types, existing analytical expressions were identified to determine the magnitudes of harmonic currents, and waveforms of currents were obtained during measurements in laboratory conditions with variable parameters of the grid impedance and load. The obtained results were compared, and it was found that the error in determining the magnitudes of harmonic currents can reach 60% for an individual load and 54% for an equivalent load. A more accurate method for determining the parameters of nonlinear electrical load is also proposed, which is based on the application of shunt harmonic filters. In laboratory conditions, it was found that when using the developed method, the error did not exceed 10% for an individual load and 14% for an equivalent load.Aleksandr SkamyinYaroslav ShklyarskiyVasiliy DobushIuliia DobushMDPI AGarticleharmonicstotal harmonic distortionpower qualitynonlinear electrical loadcapacitor bankspassive filtersTechnologyTENEnergies, Vol 14, Iss 7762, p 7762 (2021)
institution DOAJ
collection DOAJ
language EN
topic harmonics
total harmonic distortion
power quality
nonlinear electrical load
capacitor banks
passive filters
Technology
T
spellingShingle harmonics
total harmonic distortion
power quality
nonlinear electrical load
capacitor banks
passive filters
Technology
T
Aleksandr Skamyin
Yaroslav Shklyarskiy
Vasiliy Dobush
Iuliia Dobush
Experimental Determination of Parameters of Nonlinear Electrical Load
description The paper deals with issues of modeling nonlinear electrical loads of various types, such an uncontrolled rectifier, thyristor rectifier, thyristor power regulator and mixed equivalent nonlinear load. For these load types, existing analytical expressions were identified to determine the magnitudes of harmonic currents, and waveforms of currents were obtained during measurements in laboratory conditions with variable parameters of the grid impedance and load. The obtained results were compared, and it was found that the error in determining the magnitudes of harmonic currents can reach 60% for an individual load and 54% for an equivalent load. A more accurate method for determining the parameters of nonlinear electrical load is also proposed, which is based on the application of shunt harmonic filters. In laboratory conditions, it was found that when using the developed method, the error did not exceed 10% for an individual load and 14% for an equivalent load.
format article
author Aleksandr Skamyin
Yaroslav Shklyarskiy
Vasiliy Dobush
Iuliia Dobush
author_facet Aleksandr Skamyin
Yaroslav Shklyarskiy
Vasiliy Dobush
Iuliia Dobush
author_sort Aleksandr Skamyin
title Experimental Determination of Parameters of Nonlinear Electrical Load
title_short Experimental Determination of Parameters of Nonlinear Electrical Load
title_full Experimental Determination of Parameters of Nonlinear Electrical Load
title_fullStr Experimental Determination of Parameters of Nonlinear Electrical Load
title_full_unstemmed Experimental Determination of Parameters of Nonlinear Electrical Load
title_sort experimental determination of parameters of nonlinear electrical load
publisher MDPI AG
publishDate 2021
url https://doaj.org/article/8e96d2cfe3e049cbb72d7fc033d9e2b7
work_keys_str_mv AT aleksandrskamyin experimentaldeterminationofparametersofnonlinearelectricalload
AT yaroslavshklyarskiy experimentaldeterminationofparametersofnonlinearelectricalload
AT vasiliydobush experimentaldeterminationofparametersofnonlinearelectricalload
AT iuliiadobush experimentaldeterminationofparametersofnonlinearelectricalload
_version_ 1718412297579266048