Analysis of Wave Propagation in Detection of Aorta DiesesUsing Lumps Analysis

In this paper a theoretical attempt is made to determine whether changes in the aorta diameter at different location along the aorta can be detected by brachial artery measurement. The aorta is divided into six main parts, each part with 4 lumps of 0.018m length. It is assumed that a desired section...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: A. Salam Al-Ammri, A. M Al-Jumaily
Formato: article
Lenguaje:EN
Publicado: Al-Khwarizmi College of Engineering – University of Baghdad 2009
Materias:
Acceso en línea:https://doaj.org/article/8e9f879ae88b45d3bf71d2c30a0580ce
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:8e9f879ae88b45d3bf71d2c30a0580ce
record_format dspace
spelling oai:doaj.org-article:8e9f879ae88b45d3bf71d2c30a0580ce2021-12-02T04:45:01ZAnalysis of Wave Propagation in Detection of Aorta DiesesUsing Lumps Analysis1818-1171https://doaj.org/article/8e9f879ae88b45d3bf71d2c30a0580ce2009-01-01T00:00:00Zhttp://www.iasj.net/iasj?func=fulltext&aId=2358https://doaj.org/toc/1818-1171In this paper a theoretical attempt is made to determine whether changes in the aorta diameter at different location along the aorta can be detected by brachial artery measurement. The aorta is divided into six main parts, each part with 4 lumps of 0.018m length. It is assumed that a desired section of the aorta has a radius change of 100,200, 500%. The results show that there is a significant change for part 2 (lumps 5-8) from the other parts. This indicates that the nearest position to the artery gives the significant change in the artery wave pressure while other parts of the aorta have a small effect.A. Salam Al-AmmriA. M Al-JumailyAl-Khwarizmi College of Engineering – University of BaghdadarticleWave propagationaortalumps analysis.Chemical engineeringTP155-156Engineering (General). Civil engineering (General)TA1-2040ENAl-Khawarizmi Engineering Journal, Vol 5, Iss 3, Pp 16-22 (2009)
institution DOAJ
collection DOAJ
language EN
topic Wave propagation
aorta
lumps analysis.
Chemical engineering
TP155-156
Engineering (General). Civil engineering (General)
TA1-2040
spellingShingle Wave propagation
aorta
lumps analysis.
Chemical engineering
TP155-156
Engineering (General). Civil engineering (General)
TA1-2040
A. Salam Al-Ammri
A. M Al-Jumaily
Analysis of Wave Propagation in Detection of Aorta DiesesUsing Lumps Analysis
description In this paper a theoretical attempt is made to determine whether changes in the aorta diameter at different location along the aorta can be detected by brachial artery measurement. The aorta is divided into six main parts, each part with 4 lumps of 0.018m length. It is assumed that a desired section of the aorta has a radius change of 100,200, 500%. The results show that there is a significant change for part 2 (lumps 5-8) from the other parts. This indicates that the nearest position to the artery gives the significant change in the artery wave pressure while other parts of the aorta have a small effect.
format article
author A. Salam Al-Ammri
A. M Al-Jumaily
author_facet A. Salam Al-Ammri
A. M Al-Jumaily
author_sort A. Salam Al-Ammri
title Analysis of Wave Propagation in Detection of Aorta DiesesUsing Lumps Analysis
title_short Analysis of Wave Propagation in Detection of Aorta DiesesUsing Lumps Analysis
title_full Analysis of Wave Propagation in Detection of Aorta DiesesUsing Lumps Analysis
title_fullStr Analysis of Wave Propagation in Detection of Aorta DiesesUsing Lumps Analysis
title_full_unstemmed Analysis of Wave Propagation in Detection of Aorta DiesesUsing Lumps Analysis
title_sort analysis of wave propagation in detection of aorta diesesusing lumps analysis
publisher Al-Khwarizmi College of Engineering – University of Baghdad
publishDate 2009
url https://doaj.org/article/8e9f879ae88b45d3bf71d2c30a0580ce
work_keys_str_mv AT asalamalammri analysisofwavepropagationindetectionofaortadiesesusinglumpsanalysis
AT amaljumaily analysisofwavepropagationindetectionofaortadiesesusinglumpsanalysis
_version_ 1718401092627202048