Morphological characteristics of zone of titanium nickelide mesh prosthesis implantation after esophagocardiopexy in experiment

The results of research using 20 rabbits are presented in the article. All animals underwent esophagocardiopexia by fixing nickel titanium mesh prosthesis to the diaphragm and the anterior wall of the stomach. The morphology of tissues in contact with the implant, histological and ultramicroscopic p...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: G. F. Petlin, G. T. Dambaev, V. E. Gunther, M. M. Solovyov, V. N. Khodorenko
Formato: article
Lenguaje:RU
Publicado: Scientific Сentre for Family Health and Human Reproduction Problems 2015
Materias:
Q
Acceso en línea:https://doaj.org/article/90097296aee540bfb349efa29e3375df
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:90097296aee540bfb349efa29e3375df
record_format dspace
spelling oai:doaj.org-article:90097296aee540bfb349efa29e3375df2021-11-23T06:14:32ZMorphological characteristics of zone of titanium nickelide mesh prosthesis implantation after esophagocardiopexy in experiment2541-94202587-9596https://doaj.org/article/90097296aee540bfb349efa29e3375df2015-04-01T00:00:00Zhttps://www.actabiomedica.ru/jour/article/view/37https://doaj.org/toc/2541-9420https://doaj.org/toc/2587-9596The results of research using 20 rabbits are presented in the article. All animals underwent esophagocardiopexia by fixing nickel titanium mesh prosthesis to the diaphragm and the anterior wall of the stomach. The morphology of tissues in contact with the implant, histological and ultramicroscopic picture were assessed. Evaluation of foreign body reaction have demonstrated minimal degree of tissue reactions. After 6 weeks the changes of normal histological structure of the investigated organs were not detected. At the end of research period the collagen fibers formed the ordered structures around the metallic filaments. The obtained data have shown high biocompatibility of titanium nickelide mesh prosthesis and the low level of mesh-related complications.G. F. PetlinG. T. DambaevV. E. GuntherM. M. SolovyovV. N. KhodorenkoScientific Сentre for Family Health and Human Reproduction Problemsarticleesophagocardiopexytitanium nickelidemesh impantbiocompatibilityScienceQRUActa Biomedica Scientifica, Vol 0, Iss 2, Pp 80-84 (2015)
institution DOAJ
collection DOAJ
language RU
topic esophagocardiopexy
titanium nickelide
mesh impant
biocompatibility
Science
Q
spellingShingle esophagocardiopexy
titanium nickelide
mesh impant
biocompatibility
Science
Q
G. F. Petlin
G. T. Dambaev
V. E. Gunther
M. M. Solovyov
V. N. Khodorenko
Morphological characteristics of zone of titanium nickelide mesh prosthesis implantation after esophagocardiopexy in experiment
description The results of research using 20 rabbits are presented in the article. All animals underwent esophagocardiopexia by fixing nickel titanium mesh prosthesis to the diaphragm and the anterior wall of the stomach. The morphology of tissues in contact with the implant, histological and ultramicroscopic picture were assessed. Evaluation of foreign body reaction have demonstrated minimal degree of tissue reactions. After 6 weeks the changes of normal histological structure of the investigated organs were not detected. At the end of research period the collagen fibers formed the ordered structures around the metallic filaments. The obtained data have shown high biocompatibility of titanium nickelide mesh prosthesis and the low level of mesh-related complications.
format article
author G. F. Petlin
G. T. Dambaev
V. E. Gunther
M. M. Solovyov
V. N. Khodorenko
author_facet G. F. Petlin
G. T. Dambaev
V. E. Gunther
M. M. Solovyov
V. N. Khodorenko
author_sort G. F. Petlin
title Morphological characteristics of zone of titanium nickelide mesh prosthesis implantation after esophagocardiopexy in experiment
title_short Morphological characteristics of zone of titanium nickelide mesh prosthesis implantation after esophagocardiopexy in experiment
title_full Morphological characteristics of zone of titanium nickelide mesh prosthesis implantation after esophagocardiopexy in experiment
title_fullStr Morphological characteristics of zone of titanium nickelide mesh prosthesis implantation after esophagocardiopexy in experiment
title_full_unstemmed Morphological characteristics of zone of titanium nickelide mesh prosthesis implantation after esophagocardiopexy in experiment
title_sort morphological characteristics of zone of titanium nickelide mesh prosthesis implantation after esophagocardiopexy in experiment
publisher Scientific Сentre for Family Health and Human Reproduction Problems
publishDate 2015
url https://doaj.org/article/90097296aee540bfb349efa29e3375df
work_keys_str_mv AT gfpetlin morphologicalcharacteristicsofzoneoftitaniumnickelidemeshprosthesisimplantationafteresophagocardiopexyinexperiment
AT gtdambaev morphologicalcharacteristicsofzoneoftitaniumnickelidemeshprosthesisimplantationafteresophagocardiopexyinexperiment
AT vegunther morphologicalcharacteristicsofzoneoftitaniumnickelidemeshprosthesisimplantationafteresophagocardiopexyinexperiment
AT mmsolovyov morphologicalcharacteristicsofzoneoftitaniumnickelidemeshprosthesisimplantationafteresophagocardiopexyinexperiment
AT vnkhodorenko morphologicalcharacteristicsofzoneoftitaniumnickelidemeshprosthesisimplantationafteresophagocardiopexyinexperiment
_version_ 1718417083041054720