Automated incisional hernia characterization by non-rigid registration of CT images – a pilot study

Incisional hernia repair makes use of prosthetic meshes to re-establish a biomechanically stable abdominal wall. Mesh sizing and fixation have been found to be essential for the clinical outcome. Comparative CT images a) under rest versus b) under Valsalva maneuver (exhalation against closed airways...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Voß Samuel, Lösel Philipp D., Heuveline Vincent, Saalfeld Sylvia, Berg Philipp, Kallinowski Friedrich
Formato: article
Lenguaje:EN
Publicado: De Gruyter 2020
Materias:
R
Acceso en línea:https://doaj.org/article/9156c570207b44fa86de3ce0412f0b7c
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
Descripción
Sumario:Incisional hernia repair makes use of prosthetic meshes to re-establish a biomechanically stable abdominal wall. Mesh sizing and fixation have been found to be essential for the clinical outcome. Comparative CT images a) under rest versus b) under Valsalva maneuver (exhalation against closed airways) provide useful information for hernia characterization. However, this process incorporates several manual measurements, which led to observer variability. The present study suggests using an image registration approach of the CT data to reliably and reproducibly extract hernia quantities. The routine is implemented in the software framework MATLAB and works fully automatic. After CT data import, slice by slice undergo non-rigid B-spline grid registration. Local displacement and strain are extracted from the transformation field. The qualitative results correspond to the clinical observation. Maximum displacement of 3.5 cm and maximum strain of 25 % are calculated for one patient’s data set. Current approaches do not provide this type of information. Further research will focus on validation and possibilities to include this new kind of knowledge into the design process of prosthetic meshes.