Pneumatic tools for vitreoretinal surgery

Mario R Romano, Jose Luis Vallejo-Garcia, Alessandro Randazzo, Paolo VinciguerraIstituto Clinico Humanitas, Via Manzoni 56, 20089 Rozzano, Milan, ItalyAbstract: One of the difficulties of microsurgery is learning how to control physiological tremors. The pneumatic tool eliminates the physiological t...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Romano MR, Vallejo-Garcia JL, Randazzo A, Vinciguerra P.
Formato: article
Lenguaje:EN
Publicado: Dove Medical Press 2012
Materias:
Acceso en línea:https://doaj.org/article/91b9c52a9c0a4be6a9c561a6454d7151
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:91b9c52a9c0a4be6a9c561a6454d7151
record_format dspace
spelling oai:doaj.org-article:91b9c52a9c0a4be6a9c561a6454d71512021-12-02T02:08:16ZPneumatic tools for vitreoretinal surgery1177-54671177-5483https://doaj.org/article/91b9c52a9c0a4be6a9c561a6454d71512012-03-01T00:00:00Zhttp://www.dovepress.com/pneumatic-tools-for-vitreoretinal-surgery-a9474https://doaj.org/toc/1177-5467https://doaj.org/toc/1177-5483Mario R Romano, Jose Luis Vallejo-Garcia, Alessandro Randazzo, Paolo VinciguerraIstituto Clinico Humanitas, Via Manzoni 56, 20089 Rozzano, Milan, ItalyAbstract: One of the difficulties of microsurgery is learning how to control physiological tremors. The pneumatic tool eliminates the physiological tremor, but no tactile feedback is provided. The manual tremor when closing the forceps is completely eliminated and the exact target can be more easily grabbed. Forceps closure pressure can rise up to 50 psi, whereas the scissors can be used in two modes: multicut and proportional. When performing bimanual surgery the pedal range is divided into two steps: in the first step, the forceps are controlled, and in the second step, the forceps remain closed. At the same time the scissors start to work in the preselected mode. No adverse events occurred and no iatrogenic retinal breaks were produced. Precision and control sensation were a grateful surprise.Keywords: pneumatic forceps, pneumatic scissors, physiological tremorRomano MRVallejo-Garcia JLRandazzo AVinciguerra P.Dove Medical PressarticleOphthalmologyRE1-994ENClinical Ophthalmology, Vol 2012, Iss default, Pp 385-387 (2012)
institution DOAJ
collection DOAJ
language EN
topic Ophthalmology
RE1-994
spellingShingle Ophthalmology
RE1-994
Romano MR
Vallejo-Garcia JL
Randazzo A
Vinciguerra P.
Pneumatic tools for vitreoretinal surgery
description Mario R Romano, Jose Luis Vallejo-Garcia, Alessandro Randazzo, Paolo VinciguerraIstituto Clinico Humanitas, Via Manzoni 56, 20089 Rozzano, Milan, ItalyAbstract: One of the difficulties of microsurgery is learning how to control physiological tremors. The pneumatic tool eliminates the physiological tremor, but no tactile feedback is provided. The manual tremor when closing the forceps is completely eliminated and the exact target can be more easily grabbed. Forceps closure pressure can rise up to 50 psi, whereas the scissors can be used in two modes: multicut and proportional. When performing bimanual surgery the pedal range is divided into two steps: in the first step, the forceps are controlled, and in the second step, the forceps remain closed. At the same time the scissors start to work in the preselected mode. No adverse events occurred and no iatrogenic retinal breaks were produced. Precision and control sensation were a grateful surprise.Keywords: pneumatic forceps, pneumatic scissors, physiological tremor
format article
author Romano MR
Vallejo-Garcia JL
Randazzo A
Vinciguerra P.
author_facet Romano MR
Vallejo-Garcia JL
Randazzo A
Vinciguerra P.
author_sort Romano MR
title Pneumatic tools for vitreoretinal surgery
title_short Pneumatic tools for vitreoretinal surgery
title_full Pneumatic tools for vitreoretinal surgery
title_fullStr Pneumatic tools for vitreoretinal surgery
title_full_unstemmed Pneumatic tools for vitreoretinal surgery
title_sort pneumatic tools for vitreoretinal surgery
publisher Dove Medical Press
publishDate 2012
url https://doaj.org/article/91b9c52a9c0a4be6a9c561a6454d7151
work_keys_str_mv AT romanomr pneumatictoolsforvitreoretinalsurgery
AT vallejogarciajl pneumatictoolsforvitreoretinalsurgery
AT randazzoa pneumatictoolsforvitreoretinalsurgery
AT vinciguerrap pneumatictoolsforvitreoretinalsurgery
_version_ 1718402661910315008