Structural Considerations on Timber-Glass Composites at Fire Scenarios

This paper focuses on a recently developed concept, in which glass is combined with timber to provide post-breakage strength and ductility. This combination allows for good post-breakage performance and overall robustness of timber-glass composite beams and wall elements, which has been reported in...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Marcin Kozłowski, Peter Lenk, Michael Dorn, Dániel Honfi, Johan Sjöström
Formato: article
Lenguaje:EN
Publicado: Challenging Glass Conference 2018
Materias:
Acceso en línea:https://doaj.org/article/9255a561b6b54345ab870d352847faa1
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
Descripción
Sumario:This paper focuses on a recently developed concept, in which glass is combined with timber to provide post-breakage strength and ductility. This combination allows for good post-breakage performance and overall robustness of timber-glass composite beams and wall elements, which has been reported in several publications. The application of timber-glass elements in practice, however, raises important issues related to structural fire performance. The paper elaborates on this issue and provides general information about the behavior of glass, timber and adhesives at elevated temperatures and under fire conditions. Furthermore, it presents ideas and strategies developed for potential application of timber-glass composites in practical situations. The paper presents also initial results from an on-going research project on fire performance of timber-glass composites.