A smartphone-assisted pressure-measuring-based diagnosis system for acute myocardial infarction diagnosis

Guolin Hong,1 Gang Rui,2 Dongdong Zhang,1 Mingjian Lian,1 Yuanyuan Yang,1 Ping Chen,1 Huijing Yang,3 Zhichao Guan,4 Wei Chen,5 Yan Wang6 1Department of Laboratory Medicine, The First Affiliated Hospital of Xiamen University, Xiamen 361005, People’s Republic of China; 2Department of Orthop...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Hong G, Rui G, Zhang D, Lian M, Yang Y, Chen P, Yang H, Guan Z, Chen W, Wang Y
Formato: article
Lenguaje:EN
Publicado: Dove Medical Press 2019
Materias:
Acceso en línea:https://doaj.org/article/939cda96a8dc41aea9a337a79b6ef0db
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:939cda96a8dc41aea9a337a79b6ef0db
record_format dspace
spelling oai:doaj.org-article:939cda96a8dc41aea9a337a79b6ef0db2021-12-02T07:33:00ZA smartphone-assisted pressure-measuring-based diagnosis system for acute myocardial infarction diagnosis1178-2013https://doaj.org/article/939cda96a8dc41aea9a337a79b6ef0db2019-04-01T00:00:00Zhttps://www.dovepress.com/a-smartphone-assisted-pressure-measuring-based-diagnosis-system-for-ac-peer-reviewed-article-IJNhttps://doaj.org/toc/1178-2013Guolin Hong,1 Gang Rui,2 Dongdong Zhang,1 Mingjian Lian,1 Yuanyuan Yang,1 Ping Chen,1 Huijing Yang,3 Zhichao Guan,4 Wei Chen,5 Yan Wang6 1Department of Laboratory Medicine, The First Affiliated Hospital of Xiamen University, Xiamen 361005, People’s Republic of China; 2Department of Orthopaedic Surgery, The First Affiliated Hospital of Xiamen University, Xiamen 361005, People’s Republic of China; 3Department of Clinical Medicine, Fujian Medical University, Fuzhou 350108, People’s Republic of China; 4Department of Research and development, Xiamen Passtech Co.,Ltd., Xiamen 361101, People’s Republic of China; 5Higher Educational Key Laboratory for Nano Biomedical Technology of Fujian Province, Department of Pharmaceutical Analysis, Fujian Medical University, Fuzhou 350004, People’s Republic of China; 6Department of Cardiology, the Affiliated Cardiovascular Hospital of Xiamen University, Medical College of Xiamen University, Xiamen 361004, People’s Republic of China Background: Acute myocardial infarction (AMI), usually caused by atherosclerosis of coronary artery, is the most severe manifestation of coronary artery disease which results in a large amount of death annually. A new diagnosis approach with high accuracy, reliability and low measuring-time-consuming is essential for AMI quick diagnosis. Purpose: The objective of this study was to develop a new point-of-care testing system with high accuracy and reliability for AMI quick diagnosis.Patients and methods: 50 plasma samples of acute myocardial infarction patients were analyzed by developed Smartphone-Assisted Pressure-Measuring-Based Diagnosis System (SPDS). The concentration of substrate was firstly optimized. The effect of antibody labeling and matrix solution on measuring result were then evaluated. And standard curves for cTnI, CK-MB and Myo were built for clinical sample analysis. The measuring results of 50 clinical samples were finally evaluated by comparing with the measuring result obtained by CLIA. Results: The concentration of substrate H2O2 was firstly optimized as 30% to increase measuring signal. A commercial serum matrix was chosen as the matrix solution to dilute biomarkers for standard curve building to minimize matrix effect on the accuracy of clinical plasma sample measuring. The standard curves for cTnI, CK-MB and Myo were built, with measuring dynamic range of 0–25 ng/mL, 0–33 ng/mL and 0–250 ng/mL, and limit of detection of 0.014 ng/mL, 0.16 ng/mL and 0.85 ng/mL respectively. The measuring results obtained by the developed system of 50 clinical plasma samples for three biomarkers matched well with the results obtained by chemiluminescent immunoassay.Conclusion: Due to its small device size, high sensitivity and accuracy, SPDS showed a bright potential for point-of-care testing (POCT) applications. Keywords: acute myocardial infarction, diagnosis, pressure sensor, smartphone, Pt nanoparticleHong GRui GZhang DLian MYang YChen PYang HGuan ZChen WWang YDove Medical Pressarticleacute myocardial infarctiondiagnosispressure sensorsmartphonePt nanoparticleMedicine (General)R5-920ENInternational Journal of Nanomedicine, Vol Volume 14, Pp 2451-2464 (2019)
institution DOAJ
collection DOAJ
language EN
topic acute myocardial infarction
diagnosis
pressure sensor
smartphone
Pt nanoparticle
Medicine (General)
R5-920
spellingShingle acute myocardial infarction
diagnosis
pressure sensor
smartphone
Pt nanoparticle
Medicine (General)
R5-920
Hong G
Rui G
Zhang D
Lian M
Yang Y
Chen P
Yang H
Guan Z
Chen W
Wang Y
A smartphone-assisted pressure-measuring-based diagnosis system for acute myocardial infarction diagnosis
description Guolin Hong,1 Gang Rui,2 Dongdong Zhang,1 Mingjian Lian,1 Yuanyuan Yang,1 Ping Chen,1 Huijing Yang,3 Zhichao Guan,4 Wei Chen,5 Yan Wang6 1Department of Laboratory Medicine, The First Affiliated Hospital of Xiamen University, Xiamen 361005, People’s Republic of China; 2Department of Orthopaedic Surgery, The First Affiliated Hospital of Xiamen University, Xiamen 361005, People’s Republic of China; 3Department of Clinical Medicine, Fujian Medical University, Fuzhou 350108, People’s Republic of China; 4Department of Research and development, Xiamen Passtech Co.,Ltd., Xiamen 361101, People’s Republic of China; 5Higher Educational Key Laboratory for Nano Biomedical Technology of Fujian Province, Department of Pharmaceutical Analysis, Fujian Medical University, Fuzhou 350004, People’s Republic of China; 6Department of Cardiology, the Affiliated Cardiovascular Hospital of Xiamen University, Medical College of Xiamen University, Xiamen 361004, People’s Republic of China Background: Acute myocardial infarction (AMI), usually caused by atherosclerosis of coronary artery, is the most severe manifestation of coronary artery disease which results in a large amount of death annually. A new diagnosis approach with high accuracy, reliability and low measuring-time-consuming is essential for AMI quick diagnosis. Purpose: The objective of this study was to develop a new point-of-care testing system with high accuracy and reliability for AMI quick diagnosis.Patients and methods: 50 plasma samples of acute myocardial infarction patients were analyzed by developed Smartphone-Assisted Pressure-Measuring-Based Diagnosis System (SPDS). The concentration of substrate was firstly optimized. The effect of antibody labeling and matrix solution on measuring result were then evaluated. And standard curves for cTnI, CK-MB and Myo were built for clinical sample analysis. The measuring results of 50 clinical samples were finally evaluated by comparing with the measuring result obtained by CLIA. Results: The concentration of substrate H2O2 was firstly optimized as 30% to increase measuring signal. A commercial serum matrix was chosen as the matrix solution to dilute biomarkers for standard curve building to minimize matrix effect on the accuracy of clinical plasma sample measuring. The standard curves for cTnI, CK-MB and Myo were built, with measuring dynamic range of 0–25 ng/mL, 0–33 ng/mL and 0–250 ng/mL, and limit of detection of 0.014 ng/mL, 0.16 ng/mL and 0.85 ng/mL respectively. The measuring results obtained by the developed system of 50 clinical plasma samples for three biomarkers matched well with the results obtained by chemiluminescent immunoassay.Conclusion: Due to its small device size, high sensitivity and accuracy, SPDS showed a bright potential for point-of-care testing (POCT) applications. Keywords: acute myocardial infarction, diagnosis, pressure sensor, smartphone, Pt nanoparticle
format article
author Hong G
Rui G
Zhang D
Lian M
Yang Y
Chen P
Yang H
Guan Z
Chen W
Wang Y
author_facet Hong G
Rui G
Zhang D
Lian M
Yang Y
Chen P
Yang H
Guan Z
Chen W
Wang Y
author_sort Hong G
title A smartphone-assisted pressure-measuring-based diagnosis system for acute myocardial infarction diagnosis
title_short A smartphone-assisted pressure-measuring-based diagnosis system for acute myocardial infarction diagnosis
title_full A smartphone-assisted pressure-measuring-based diagnosis system for acute myocardial infarction diagnosis
title_fullStr A smartphone-assisted pressure-measuring-based diagnosis system for acute myocardial infarction diagnosis
title_full_unstemmed A smartphone-assisted pressure-measuring-based diagnosis system for acute myocardial infarction diagnosis
title_sort smartphone-assisted pressure-measuring-based diagnosis system for acute myocardial infarction diagnosis
publisher Dove Medical Press
publishDate 2019
url https://doaj.org/article/939cda96a8dc41aea9a337a79b6ef0db
work_keys_str_mv AT hongg asmartphoneassistedpressuremeasuringbaseddiagnosissystemforacutemyocardialinfarctiondiagnosis
AT ruig asmartphoneassistedpressuremeasuringbaseddiagnosissystemforacutemyocardialinfarctiondiagnosis
AT zhangd asmartphoneassistedpressuremeasuringbaseddiagnosissystemforacutemyocardialinfarctiondiagnosis
AT lianm asmartphoneassistedpressuremeasuringbaseddiagnosissystemforacutemyocardialinfarctiondiagnosis
AT yangy asmartphoneassistedpressuremeasuringbaseddiagnosissystemforacutemyocardialinfarctiondiagnosis
AT chenp asmartphoneassistedpressuremeasuringbaseddiagnosissystemforacutemyocardialinfarctiondiagnosis
AT yangh asmartphoneassistedpressuremeasuringbaseddiagnosissystemforacutemyocardialinfarctiondiagnosis
AT guanz asmartphoneassistedpressuremeasuringbaseddiagnosissystemforacutemyocardialinfarctiondiagnosis
AT chenw asmartphoneassistedpressuremeasuringbaseddiagnosissystemforacutemyocardialinfarctiondiagnosis
AT wangy asmartphoneassistedpressuremeasuringbaseddiagnosissystemforacutemyocardialinfarctiondiagnosis
AT hongg smartphoneassistedpressuremeasuringbaseddiagnosissystemforacutemyocardialinfarctiondiagnosis
AT ruig smartphoneassistedpressuremeasuringbaseddiagnosissystemforacutemyocardialinfarctiondiagnosis
AT zhangd smartphoneassistedpressuremeasuringbaseddiagnosissystemforacutemyocardialinfarctiondiagnosis
AT lianm smartphoneassistedpressuremeasuringbaseddiagnosissystemforacutemyocardialinfarctiondiagnosis
AT yangy smartphoneassistedpressuremeasuringbaseddiagnosissystemforacutemyocardialinfarctiondiagnosis
AT chenp smartphoneassistedpressuremeasuringbaseddiagnosissystemforacutemyocardialinfarctiondiagnosis
AT yangh smartphoneassistedpressuremeasuringbaseddiagnosissystemforacutemyocardialinfarctiondiagnosis
AT guanz smartphoneassistedpressuremeasuringbaseddiagnosissystemforacutemyocardialinfarctiondiagnosis
AT chenw smartphoneassistedpressuremeasuringbaseddiagnosissystemforacutemyocardialinfarctiondiagnosis
AT wangy smartphoneassistedpressuremeasuringbaseddiagnosissystemforacutemyocardialinfarctiondiagnosis
_version_ 1718399351069343744