A simple, wide bandwidth, biopotential amplifier to record pacemaker pulse waveform

Paolo Bifulco,1 Gaetano Dario Gargiulo,2 Maria Romano,3 Mario Cesarelli1 1Department of Electrical Engineering and Information Technology, University of Naples “Federico II”, Naples, Italy; 2The MARCS Institute, Western Sydney University, Penrith, NSW, Australia; 3DMSC, Universit...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Bifulco P, Gargiulo GD, Romano M, Cesarelli M
Formato: article
Lenguaje:EN
Publicado: Dove Medical Press 2016
Materias:
Acceso en línea:https://doaj.org/article/94326a07f8c145af97509c69c08721e3
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:94326a07f8c145af97509c69c08721e3
record_format dspace
spelling oai:doaj.org-article:94326a07f8c145af97509c69c08721e32021-12-02T02:39:58ZA simple, wide bandwidth, biopotential amplifier to record pacemaker pulse waveform1179-1470https://doaj.org/article/94326a07f8c145af97509c69c08721e32016-09-01T00:00:00Zhttps://www.dovepress.com/a-simple-wide-bandwidth-biopotential-amplifier-to-record-pacemaker-pul-peer-reviewed-article-MDERhttps://doaj.org/toc/1179-1470Paolo Bifulco,1 Gaetano Dario Gargiulo,2 Maria Romano,3 Mario Cesarelli1 1Department of Electrical Engineering and Information Technology, University of Naples “Federico II”, Naples, Italy; 2The MARCS Institute, Western Sydney University, Penrith, NSW, Australia; 3DMSC, University “Magna Graecia”, Germaneto, Catanzaro, Italy Abstract: Reliable detection of pacemaker pulses is getting more and more important in electrocardiography (ECG) diagnosis. Many studies recommend ECG amplifiers with higher bandwidth to prevent errors. In the past, few pilot studies showed that analysis of pacemaker pulses waveform can enhance diagnosis (eg, lead failure and fractured wire), but they were carried out with inadequate instrumentations for clinical practice. Typically, pacemaker pulses last hundreds of microseconds, edges of pulses elapse in few microseconds, and amplitude may exhibit large variations from few millivolts to volts. Pulse waveforms change often and depend on pacemaker type and programming. A simple, biopotential amplifier made of a few off-the-shelf components is proposed. The circuit fulfills specifications for biopotential amplifiers and offers a large bandwidth (~1 MHz). Therefore, it is able to accurately record time course of pacemaker pulses and allows highly accurate pulse detection and timing. Signals can be easily displayed and acquired by means of a standard, battery-powered oscilloscope. Pacemaker pulse vectorcardiography can be obtained by using two or more, wideband channels. Some exemplificative waveforms recorded during patient’s periodic medical examination are reported. The proposed circuit offers simultaneous conventional ECG signal as an additional output. Keywords: wideband biopotential amplifiers, pacemaker pulse waveform, electrocardiography deviceBifulco PGargiulo GDRomano MCesarelli MDove Medical Pressarticlewideband biopotential amplifierspacemaker pulse waveformelectrocardiography deviceMedical technologyR855-855.5ENMedical Devices: Evidence and Research, Vol Volume 9, Pp 325-329 (2016)
institution DOAJ
collection DOAJ
language EN
topic wideband biopotential amplifiers
pacemaker pulse waveform
electrocardiography device
Medical technology
R855-855.5
spellingShingle wideband biopotential amplifiers
pacemaker pulse waveform
electrocardiography device
Medical technology
R855-855.5
Bifulco P
Gargiulo GD
Romano M
Cesarelli M
A simple, wide bandwidth, biopotential amplifier to record pacemaker pulse waveform
description Paolo Bifulco,1 Gaetano Dario Gargiulo,2 Maria Romano,3 Mario Cesarelli1 1Department of Electrical Engineering and Information Technology, University of Naples “Federico II”, Naples, Italy; 2The MARCS Institute, Western Sydney University, Penrith, NSW, Australia; 3DMSC, University “Magna Graecia”, Germaneto, Catanzaro, Italy Abstract: Reliable detection of pacemaker pulses is getting more and more important in electrocardiography (ECG) diagnosis. Many studies recommend ECG amplifiers with higher bandwidth to prevent errors. In the past, few pilot studies showed that analysis of pacemaker pulses waveform can enhance diagnosis (eg, lead failure and fractured wire), but they were carried out with inadequate instrumentations for clinical practice. Typically, pacemaker pulses last hundreds of microseconds, edges of pulses elapse in few microseconds, and amplitude may exhibit large variations from few millivolts to volts. Pulse waveforms change often and depend on pacemaker type and programming. A simple, biopotential amplifier made of a few off-the-shelf components is proposed. The circuit fulfills specifications for biopotential amplifiers and offers a large bandwidth (~1 MHz). Therefore, it is able to accurately record time course of pacemaker pulses and allows highly accurate pulse detection and timing. Signals can be easily displayed and acquired by means of a standard, battery-powered oscilloscope. Pacemaker pulse vectorcardiography can be obtained by using two or more, wideband channels. Some exemplificative waveforms recorded during patient’s periodic medical examination are reported. The proposed circuit offers simultaneous conventional ECG signal as an additional output. Keywords: wideband biopotential amplifiers, pacemaker pulse waveform, electrocardiography device
format article
author Bifulco P
Gargiulo GD
Romano M
Cesarelli M
author_facet Bifulco P
Gargiulo GD
Romano M
Cesarelli M
author_sort Bifulco P
title A simple, wide bandwidth, biopotential amplifier to record pacemaker pulse waveform
title_short A simple, wide bandwidth, biopotential amplifier to record pacemaker pulse waveform
title_full A simple, wide bandwidth, biopotential amplifier to record pacemaker pulse waveform
title_fullStr A simple, wide bandwidth, biopotential amplifier to record pacemaker pulse waveform
title_full_unstemmed A simple, wide bandwidth, biopotential amplifier to record pacemaker pulse waveform
title_sort simple, wide bandwidth, biopotential amplifier to record pacemaker pulse waveform
publisher Dove Medical Press
publishDate 2016
url https://doaj.org/article/94326a07f8c145af97509c69c08721e3
work_keys_str_mv AT bifulcop asimplewidebandwidthbiopotentialamplifiertorecordpacemakerpulsewaveform
AT gargiulogd asimplewidebandwidthbiopotentialamplifiertorecordpacemakerpulsewaveform
AT romanom asimplewidebandwidthbiopotentialamplifiertorecordpacemakerpulsewaveform
AT cesarellim asimplewidebandwidthbiopotentialamplifiertorecordpacemakerpulsewaveform
AT bifulcop simplewidebandwidthbiopotentialamplifiertorecordpacemakerpulsewaveform
AT gargiulogd simplewidebandwidthbiopotentialamplifiertorecordpacemakerpulsewaveform
AT romanom simplewidebandwidthbiopotentialamplifiertorecordpacemakerpulsewaveform
AT cesarellim simplewidebandwidthbiopotentialamplifiertorecordpacemakerpulsewaveform
_version_ 1718402304166592512