Highly sensitive determination of α-lipoic acid in pharmaceuticals on a boron-doped diamond electrode

A simple, highly sensitive, and selective differential pulse voltammetry method for the determination of α-lipoic acid (LA) in pharmaceutical preparations was developed and validated. The method is based on a quasi-reversible, diffusion-controlled, one-electron anodic oxidation of LA on a boron-dope...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Skorupa Agata, Michalkiewicz Slawomir, Jakubczyk Magdalena
Formato: article
Lenguaje:EN
Publicado: De Gruyter 2021
Materias:
Acceso en línea:https://doaj.org/article/9477a08d2366475699fa121df8f000fa
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:9477a08d2366475699fa121df8f000fa
record_format dspace
spelling oai:doaj.org-article:9477a08d2366475699fa121df8f000fa2021-12-05T14:10:44ZHighly sensitive determination of α-lipoic acid in pharmaceuticals on a boron-doped diamond electrode2391-542010.1515/chem-2021-0075https://doaj.org/article/9477a08d2366475699fa121df8f000fa2021-08-01T00:00:00Zhttps://doi.org/10.1515/chem-2021-0075https://doaj.org/toc/2391-5420A simple, highly sensitive, and selective differential pulse voltammetry method for the determination of α-lipoic acid (LA) in pharmaceutical preparations was developed and validated. The method is based on a quasi-reversible, diffusion-controlled, one-electron anodic oxidation of LA on a boron-doped diamond electrode (BDDE) in a McIlvaine (citrate-phosphate, C-PB) buffer solution at pH 3.0. For the first time, this environment was used for LA determination. A linear calibration curve was obtained within the concentration range 5.82 × 10−8 to 4.00 × 10−4 mol L−1 with a correlation coefficient of 0.9999. The limits of detection was estimated to be 1.94 × 10−8 mol L−1, which is one of the lowest values characteristic of voltammetric and chromatographic methods of LA determination. The proposed procedure is sensitive, accurate, and precise. Its utility was demonstrated in the determination of LA in pharmaceuticals without the need for its separation from the matrices. The results were comparable to those obtained by high performance liquid chromatography reference method and were in good accordance with the once declared by manufacturers. Thus, our method can be considered as an alternative to the dominant chromatographic determinations of α-LA in real samples.Skorupa AgataMichalkiewicz SlawomirJakubczyk MagdalenaDe Gruyterarticleα-laoxidationdeterminationbddeaqueous buffersChemistryQD1-999ENOpen Chemistry, Vol 19, Iss 1, Pp 843-854 (2021)
institution DOAJ
collection DOAJ
language EN
topic α-la
oxidation
determination
bdde
aqueous buffers
Chemistry
QD1-999
spellingShingle α-la
oxidation
determination
bdde
aqueous buffers
Chemistry
QD1-999
Skorupa Agata
Michalkiewicz Slawomir
Jakubczyk Magdalena
Highly sensitive determination of α-lipoic acid in pharmaceuticals on a boron-doped diamond electrode
description A simple, highly sensitive, and selective differential pulse voltammetry method for the determination of α-lipoic acid (LA) in pharmaceutical preparations was developed and validated. The method is based on a quasi-reversible, diffusion-controlled, one-electron anodic oxidation of LA on a boron-doped diamond electrode (BDDE) in a McIlvaine (citrate-phosphate, C-PB) buffer solution at pH 3.0. For the first time, this environment was used for LA determination. A linear calibration curve was obtained within the concentration range 5.82 × 10−8 to 4.00 × 10−4 mol L−1 with a correlation coefficient of 0.9999. The limits of detection was estimated to be 1.94 × 10−8 mol L−1, which is one of the lowest values characteristic of voltammetric and chromatographic methods of LA determination. The proposed procedure is sensitive, accurate, and precise. Its utility was demonstrated in the determination of LA in pharmaceuticals without the need for its separation from the matrices. The results were comparable to those obtained by high performance liquid chromatography reference method and were in good accordance with the once declared by manufacturers. Thus, our method can be considered as an alternative to the dominant chromatographic determinations of α-LA in real samples.
format article
author Skorupa Agata
Michalkiewicz Slawomir
Jakubczyk Magdalena
author_facet Skorupa Agata
Michalkiewicz Slawomir
Jakubczyk Magdalena
author_sort Skorupa Agata
title Highly sensitive determination of α-lipoic acid in pharmaceuticals on a boron-doped diamond electrode
title_short Highly sensitive determination of α-lipoic acid in pharmaceuticals on a boron-doped diamond electrode
title_full Highly sensitive determination of α-lipoic acid in pharmaceuticals on a boron-doped diamond electrode
title_fullStr Highly sensitive determination of α-lipoic acid in pharmaceuticals on a boron-doped diamond electrode
title_full_unstemmed Highly sensitive determination of α-lipoic acid in pharmaceuticals on a boron-doped diamond electrode
title_sort highly sensitive determination of α-lipoic acid in pharmaceuticals on a boron-doped diamond electrode
publisher De Gruyter
publishDate 2021
url https://doaj.org/article/9477a08d2366475699fa121df8f000fa
work_keys_str_mv AT skorupaagata highlysensitivedeterminationofalipoicacidinpharmaceuticalsonaborondopeddiamondelectrode
AT michalkiewiczslawomir highlysensitivedeterminationofalipoicacidinpharmaceuticalsonaborondopeddiamondelectrode
AT jakubczykmagdalena highlysensitivedeterminationofalipoicacidinpharmaceuticalsonaborondopeddiamondelectrode
_version_ 1718371796758036480