Clinical Outcomes, Contrast Sensitivity, Reading Performance and Patient Satisfaction Following Bilateral Implantation of AT LARA 829MP EDoF IOLs

Sri Ganesh, Sheetal Brar, Nikhil RP, Dishitha Rathod Department of Phaco-Refractive Surgery, Nethradhama Super Speciality Eye Hospital, Bangalore, Karnataka, IndiaCorrespondence: Sheetal BrarNethradhama Superspeciality Eye Hospital, 256/14, Kanakapura Main Road, 7th Block, Jayanagar, Bengaluru, Karn...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Ganesh S, Brar S, RP N, Rathod D
Formato: article
Lenguaje:EN
Publicado: Dove Medical Press 2021
Materias:
Acceso en línea:https://doaj.org/article/95ab8d2916a24c4991a5ec4ef935efe7
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:95ab8d2916a24c4991a5ec4ef935efe7
record_format dspace
spelling oai:doaj.org-article:95ab8d2916a24c4991a5ec4ef935efe72021-12-02T16:52:25ZClinical Outcomes, Contrast Sensitivity, Reading Performance and Patient Satisfaction Following Bilateral Implantation of AT LARA 829MP EDoF IOLs1177-5483https://doaj.org/article/95ab8d2916a24c4991a5ec4ef935efe72021-10-01T00:00:00Zhttps://www.dovepress.com/clinical-outcomes-contrast-sensitivity-reading-performance-and-patient-peer-reviewed-fulltext-article-OPTHhttps://doaj.org/toc/1177-5483Sri Ganesh, Sheetal Brar, Nikhil RP, Dishitha Rathod Department of Phaco-Refractive Surgery, Nethradhama Super Speciality Eye Hospital, Bangalore, Karnataka, IndiaCorrespondence: Sheetal BrarNethradhama Superspeciality Eye Hospital, 256/14, Kanakapura Main Road, 7th Block, Jayanagar, Bengaluru, Karnataka, 560070, IndiaTel +919591002092Email brar_sheetal@yahoo.co.inPurpose: To evaluate the visual outcomes, contrast sensitivity, reading performance and patient satisfaction after bilateral implantation of AT LARA extended depth of focus (EDoF) intraocular lenses (IOLs).Methods: Patients undergoing phacoemulsification for age-related cataract and satisfying the eligibility criteria underwent bilateral implantation with AT LARA EDoF IOLs (Carl Zeiss Meditec, Jena, Germany). At follow-up visits of 1, 3, 6 and 12 months, binocular uncorrected and corrected distance, intermediate and near visual acuity, reading performance, defocus curve, contrast sensitivity and patient satisfaction for dysphotopsia and spectacle independence were evaluated.Results: A total of 60 eyes from 30 patients with a mean age of 65.40± 7.71 years were included in the study. At 12 months, 83% of patients (n=25) had binocular cumulative uncorrected distance visual acuity (UDVA) of 20/20 or better. Postoperative spherical equivalent refraction accuracy was within ± 0.50 D for 95% of eyes (n=57) and refractive cylinder accuracy was within ≤ 0.50 D in 95% of eyes (n=57). The mean binocular uncorrected near visual acuity (UNVA) was 0.16± 0.09 logMAR, and the mean uncorrected intermediate visual acuity (UIVA) at 60 and 80 cm was 0.01± 0.09 and 0.03± 0.08 logMAR, respectively, at 12 months. Reading speeds at 40, 60 and 80 cm showed improvement over time. No patient had complaints of severe dysphotopsia and none of the patients required glasses for any activity. No eye underwent YAG-laser capsulotomy for significant posterior capsule opacification at the end of mean follow-up.Conclusion: In our limited experience of 30 patients at 12 months, AT LARA EDoF IOLs resulted in excellent visual outcomes for uncorrected distance, intermediate and near visual acuity. The incidence of dysphotopsia and spectacle dependence was low, resulting in good patient satisfaction.Trial Registry: CTRI/2020/08/027105 (www.ctri.nic.in).Keywords: AT LARA, extended depth of focus, EDoF IOL, spectacle independenceGanesh SBrar SRP NRathod DDove Medical Pressarticleat laraextended depth of focusedof iolspectacle independenceOphthalmologyRE1-994ENClinical Ophthalmology, Vol Volume 15, Pp 4247-4257 (2021)
institution DOAJ
collection DOAJ
language EN
topic at lara
extended depth of focus
edof iol
spectacle independence
Ophthalmology
RE1-994
spellingShingle at lara
extended depth of focus
edof iol
spectacle independence
Ophthalmology
RE1-994
Ganesh S
Brar S
RP N
Rathod D
Clinical Outcomes, Contrast Sensitivity, Reading Performance and Patient Satisfaction Following Bilateral Implantation of AT LARA 829MP EDoF IOLs
description Sri Ganesh, Sheetal Brar, Nikhil RP, Dishitha Rathod Department of Phaco-Refractive Surgery, Nethradhama Super Speciality Eye Hospital, Bangalore, Karnataka, IndiaCorrespondence: Sheetal BrarNethradhama Superspeciality Eye Hospital, 256/14, Kanakapura Main Road, 7th Block, Jayanagar, Bengaluru, Karnataka, 560070, IndiaTel +919591002092Email brar_sheetal@yahoo.co.inPurpose: To evaluate the visual outcomes, contrast sensitivity, reading performance and patient satisfaction after bilateral implantation of AT LARA extended depth of focus (EDoF) intraocular lenses (IOLs).Methods: Patients undergoing phacoemulsification for age-related cataract and satisfying the eligibility criteria underwent bilateral implantation with AT LARA EDoF IOLs (Carl Zeiss Meditec, Jena, Germany). At follow-up visits of 1, 3, 6 and 12 months, binocular uncorrected and corrected distance, intermediate and near visual acuity, reading performance, defocus curve, contrast sensitivity and patient satisfaction for dysphotopsia and spectacle independence were evaluated.Results: A total of 60 eyes from 30 patients with a mean age of 65.40± 7.71 years were included in the study. At 12 months, 83% of patients (n=25) had binocular cumulative uncorrected distance visual acuity (UDVA) of 20/20 or better. Postoperative spherical equivalent refraction accuracy was within ± 0.50 D for 95% of eyes (n=57) and refractive cylinder accuracy was within ≤ 0.50 D in 95% of eyes (n=57). The mean binocular uncorrected near visual acuity (UNVA) was 0.16± 0.09 logMAR, and the mean uncorrected intermediate visual acuity (UIVA) at 60 and 80 cm was 0.01± 0.09 and 0.03± 0.08 logMAR, respectively, at 12 months. Reading speeds at 40, 60 and 80 cm showed improvement over time. No patient had complaints of severe dysphotopsia and none of the patients required glasses for any activity. No eye underwent YAG-laser capsulotomy for significant posterior capsule opacification at the end of mean follow-up.Conclusion: In our limited experience of 30 patients at 12 months, AT LARA EDoF IOLs resulted in excellent visual outcomes for uncorrected distance, intermediate and near visual acuity. The incidence of dysphotopsia and spectacle dependence was low, resulting in good patient satisfaction.Trial Registry: CTRI/2020/08/027105 (www.ctri.nic.in).Keywords: AT LARA, extended depth of focus, EDoF IOL, spectacle independence
format article
author Ganesh S
Brar S
RP N
Rathod D
author_facet Ganesh S
Brar S
RP N
Rathod D
author_sort Ganesh S
title Clinical Outcomes, Contrast Sensitivity, Reading Performance and Patient Satisfaction Following Bilateral Implantation of AT LARA 829MP EDoF IOLs
title_short Clinical Outcomes, Contrast Sensitivity, Reading Performance and Patient Satisfaction Following Bilateral Implantation of AT LARA 829MP EDoF IOLs
title_full Clinical Outcomes, Contrast Sensitivity, Reading Performance and Patient Satisfaction Following Bilateral Implantation of AT LARA 829MP EDoF IOLs
title_fullStr Clinical Outcomes, Contrast Sensitivity, Reading Performance and Patient Satisfaction Following Bilateral Implantation of AT LARA 829MP EDoF IOLs
title_full_unstemmed Clinical Outcomes, Contrast Sensitivity, Reading Performance and Patient Satisfaction Following Bilateral Implantation of AT LARA 829MP EDoF IOLs
title_sort clinical outcomes, contrast sensitivity, reading performance and patient satisfaction following bilateral implantation of at lara 829mp edof iols
publisher Dove Medical Press
publishDate 2021
url https://doaj.org/article/95ab8d2916a24c4991a5ec4ef935efe7
work_keys_str_mv AT ganeshs clinicaloutcomescontrastsensitivityreadingperformanceandpatientsatisfactionfollowingbilateralimplantationofatlara829mpedofiols
AT brars clinicaloutcomescontrastsensitivityreadingperformanceandpatientsatisfactionfollowingbilateralimplantationofatlara829mpedofiols
AT rpn clinicaloutcomescontrastsensitivityreadingperformanceandpatientsatisfactionfollowingbilateralimplantationofatlara829mpedofiols
AT rathodd clinicaloutcomescontrastsensitivityreadingperformanceandpatientsatisfactionfollowingbilateralimplantationofatlara829mpedofiols
_version_ 1718382934187048960