Evaluation of monoxide film-based dosimeters for surface dose detection in electron therapy.

Generally, electron therapy is applied to tumors on or close to the skin surface. However, this causes a variety of skin-related side effects. To alleviate the risk of these side effects, clinical treatment uses skin dosimeters to verify the therapeutic dose. However, dosimeters suffer from poor acc...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Moo Jae Han, Seung Woo Yang, Sang Il Bae, Young Min Moon, Wan Jeon, Chul Won Choi, Sung Kwang Park, Jin Young Kim
Formato: article
Lenguaje:EN
Publicado: Public Library of Science (PLoS) 2021
Materias:
R
Q
Acceso en línea:https://doaj.org/article/95ecac52f7a44aba9c62bc9213e3bde6
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:95ecac52f7a44aba9c62bc9213e3bde6
record_format dspace
spelling oai:doaj.org-article:95ecac52f7a44aba9c62bc9213e3bde62021-11-25T06:19:03ZEvaluation of monoxide film-based dosimeters for surface dose detection in electron therapy.1932-620310.1371/journal.pone.0251441https://doaj.org/article/95ecac52f7a44aba9c62bc9213e3bde62021-01-01T00:00:00Zhttps://doi.org/10.1371/journal.pone.0251441https://doaj.org/toc/1932-6203Generally, electron therapy is applied to tumors on or close to the skin surface. However, this causes a variety of skin-related side effects. To alleviate the risk of these side effects, clinical treatment uses skin dosimeters to verify the therapeutic dose. However, dosimeters suffer from poor accuracy, because their attachment sites are approximated with the help of naked eyes. Therefore, a dosimeter based on a flexible material that can adjust to the contours of the human body is required. In this study, the reproducibility, linearity, dose-rate dependence, and percentage depth ionization (PDI) of PbO and HgO film-based dosimeters are evaluated to explore their potential as large-scale flexible dosimeters. The results demonstrate that both dosimeters deliver impressive reproducibility (within 1.5%) and linearity (≥ 0.9990). The relative standard deviations of the dose-rate dependence of the PbO and HgO dosimeters were 0.94% and 1.16% at 6 MeV, respectively, and 1.08% and 1.25% at 9 MeV, respectively, with the PbO dosimeter outperforming the 1.1% of existing diodes. The PDI analysis of the PbO and HgO dosimeters returned values of 0.014 cm (-0.074 cm) and 0.051 cm (-0.016 cm), respectively at 6 MeV (9 MeV) compared to the thimble chamber and R50. Therefore, the maximum error of each dosimeter is within the allowable range of 0.1 cm. In short, the analysis reveals that the PbO dosimeter delivers a superior performance relative to its HgO counterpart and has strong potential for use as a surface dosimeter. Thus, flexible monoxide materials have the necessary qualities to be used for dosimeters that meet the requisite quality assurance standards and can satisfy a variety of radiation-related applications as flexible functional materials.Moo Jae HanSeung Woo YangSang Il BaeYoung Min MoonWan JeonChul Won ChoiSung Kwang ParkJin Young KimPublic Library of Science (PLoS)articleMedicineRScienceQENPLoS ONE, Vol 16, Iss 5, p e0251441 (2021)
institution DOAJ
collection DOAJ
language EN
topic Medicine
R
Science
Q
spellingShingle Medicine
R
Science
Q
Moo Jae Han
Seung Woo Yang
Sang Il Bae
Young Min Moon
Wan Jeon
Chul Won Choi
Sung Kwang Park
Jin Young Kim
Evaluation of monoxide film-based dosimeters for surface dose detection in electron therapy.
description Generally, electron therapy is applied to tumors on or close to the skin surface. However, this causes a variety of skin-related side effects. To alleviate the risk of these side effects, clinical treatment uses skin dosimeters to verify the therapeutic dose. However, dosimeters suffer from poor accuracy, because their attachment sites are approximated with the help of naked eyes. Therefore, a dosimeter based on a flexible material that can adjust to the contours of the human body is required. In this study, the reproducibility, linearity, dose-rate dependence, and percentage depth ionization (PDI) of PbO and HgO film-based dosimeters are evaluated to explore their potential as large-scale flexible dosimeters. The results demonstrate that both dosimeters deliver impressive reproducibility (within 1.5%) and linearity (≥ 0.9990). The relative standard deviations of the dose-rate dependence of the PbO and HgO dosimeters were 0.94% and 1.16% at 6 MeV, respectively, and 1.08% and 1.25% at 9 MeV, respectively, with the PbO dosimeter outperforming the 1.1% of existing diodes. The PDI analysis of the PbO and HgO dosimeters returned values of 0.014 cm (-0.074 cm) and 0.051 cm (-0.016 cm), respectively at 6 MeV (9 MeV) compared to the thimble chamber and R50. Therefore, the maximum error of each dosimeter is within the allowable range of 0.1 cm. In short, the analysis reveals that the PbO dosimeter delivers a superior performance relative to its HgO counterpart and has strong potential for use as a surface dosimeter. Thus, flexible monoxide materials have the necessary qualities to be used for dosimeters that meet the requisite quality assurance standards and can satisfy a variety of radiation-related applications as flexible functional materials.
format article
author Moo Jae Han
Seung Woo Yang
Sang Il Bae
Young Min Moon
Wan Jeon
Chul Won Choi
Sung Kwang Park
Jin Young Kim
author_facet Moo Jae Han
Seung Woo Yang
Sang Il Bae
Young Min Moon
Wan Jeon
Chul Won Choi
Sung Kwang Park
Jin Young Kim
author_sort Moo Jae Han
title Evaluation of monoxide film-based dosimeters for surface dose detection in electron therapy.
title_short Evaluation of monoxide film-based dosimeters for surface dose detection in electron therapy.
title_full Evaluation of monoxide film-based dosimeters for surface dose detection in electron therapy.
title_fullStr Evaluation of monoxide film-based dosimeters for surface dose detection in electron therapy.
title_full_unstemmed Evaluation of monoxide film-based dosimeters for surface dose detection in electron therapy.
title_sort evaluation of monoxide film-based dosimeters for surface dose detection in electron therapy.
publisher Public Library of Science (PLoS)
publishDate 2021
url https://doaj.org/article/95ecac52f7a44aba9c62bc9213e3bde6
work_keys_str_mv AT moojaehan evaluationofmonoxidefilmbaseddosimetersforsurfacedosedetectioninelectrontherapy
AT seungwooyang evaluationofmonoxidefilmbaseddosimetersforsurfacedosedetectioninelectrontherapy
AT sangilbae evaluationofmonoxidefilmbaseddosimetersforsurfacedosedetectioninelectrontherapy
AT youngminmoon evaluationofmonoxidefilmbaseddosimetersforsurfacedosedetectioninelectrontherapy
AT wanjeon evaluationofmonoxidefilmbaseddosimetersforsurfacedosedetectioninelectrontherapy
AT chulwonchoi evaluationofmonoxidefilmbaseddosimetersforsurfacedosedetectioninelectrontherapy
AT sungkwangpark evaluationofmonoxidefilmbaseddosimetersforsurfacedosedetectioninelectrontherapy
AT jinyoungkim evaluationofmonoxidefilmbaseddosimetersforsurfacedosedetectioninelectrontherapy
_version_ 1718413938876481536