Comparison of two novel swept-source optical coherence tomography devices to a partial coherence interferometry-based biometer

Abstract To evaluate the repeatability and agreement of corneal and biometry measurements obtained with two swept-source optical coherence tomography (SSOCT) and a partial coherence interferometry-based device. This is a cross-sectional study. Forty-eight eyes of 48 patients had three consecutive me...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Tommy C. Y. Chan, Marco C. Y. Yu, Vivian Chiu, Gilda Lai, Christopher K. S. Leung, Poemen P. M. Chan
Formato: article
Lenguaje:EN
Publicado: Nature Portfolio 2021
Materias:
R
Q
Acceso en línea:https://doaj.org/article/9ad3f244fc7a4143bacc46f2bc9dd2f2
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:9ad3f244fc7a4143bacc46f2bc9dd2f2
record_format dspace
spelling oai:doaj.org-article:9ad3f244fc7a4143bacc46f2bc9dd2f22021-12-02T16:17:28ZComparison of two novel swept-source optical coherence tomography devices to a partial coherence interferometry-based biometer10.1038/s41598-021-93999-82045-2322https://doaj.org/article/9ad3f244fc7a4143bacc46f2bc9dd2f22021-07-01T00:00:00Zhttps://doi.org/10.1038/s41598-021-93999-8https://doaj.org/toc/2045-2322Abstract To evaluate the repeatability and agreement of corneal and biometry measurements obtained with two swept-source optical coherence tomography (SSOCT) and a partial coherence interferometry-based device. This is a cross-sectional study. Forty-eight eyes of 48 patients had three consecutive measurements for ANTERION (Heidelberg Engineering, Germany), CASIAII (Tomey, Japan) and IOLMaster500 (Carl Zeiss Meditec, USA) on the same visit. Mean keratometry (Km), central corneal thickness (CCT), anterior chamber depth (ACD) and axial length (AL) were recorded. Corneal astigmatic measurements were converted into vector components—J0 and J45. Intra-device repeatability and agreements of measurements amongst the devices were evaluated using repeatability coefficients (RCs) and Bland–Altman plots, respectively. All devices demonstrated comparable repeatability for Km (p ≥ 0.138). ANTERION had the lowest RC for J0 amongst the devices (p ≤ 0.039). Systematic difference was found for the Km and J0 obtained with IOLMaster500 compared to either SSOCTs (p ≤ 0.010). The ACD and AL measured by IOLMaster500 showed a higher RC compared with either SSOCTs (p < 0.002). Systematic difference was found in CCT and ACD between the two SSOCTs (p < 0.001), and in AL between ANTERION and IOLMaster500 (p < 0.001), with a mean difference of 1.6 µm, 0.022 mm and 0.021 mm, respectively. Both SSOCTs demonstrated smaller test–retest variability for measuring ACD and AL compared with IOLMaster500. There were significant disagreement in keratometry and AL measurements between the SSOCTs and PCI-based device; their measurements should not be considered as interchangeable.Tommy C. Y. ChanMarco C. Y. YuVivian ChiuGilda LaiChristopher K. S. LeungPoemen P. M. ChanNature PortfolioarticleMedicineRScienceQENScientific Reports, Vol 11, Iss 1, Pp 1-9 (2021)
institution DOAJ
collection DOAJ
language EN
topic Medicine
R
Science
Q
spellingShingle Medicine
R
Science
Q
Tommy C. Y. Chan
Marco C. Y. Yu
Vivian Chiu
Gilda Lai
Christopher K. S. Leung
Poemen P. M. Chan
Comparison of two novel swept-source optical coherence tomography devices to a partial coherence interferometry-based biometer
description Abstract To evaluate the repeatability and agreement of corneal and biometry measurements obtained with two swept-source optical coherence tomography (SSOCT) and a partial coherence interferometry-based device. This is a cross-sectional study. Forty-eight eyes of 48 patients had three consecutive measurements for ANTERION (Heidelberg Engineering, Germany), CASIAII (Tomey, Japan) and IOLMaster500 (Carl Zeiss Meditec, USA) on the same visit. Mean keratometry (Km), central corneal thickness (CCT), anterior chamber depth (ACD) and axial length (AL) were recorded. Corneal astigmatic measurements were converted into vector components—J0 and J45. Intra-device repeatability and agreements of measurements amongst the devices were evaluated using repeatability coefficients (RCs) and Bland–Altman plots, respectively. All devices demonstrated comparable repeatability for Km (p ≥ 0.138). ANTERION had the lowest RC for J0 amongst the devices (p ≤ 0.039). Systematic difference was found for the Km and J0 obtained with IOLMaster500 compared to either SSOCTs (p ≤ 0.010). The ACD and AL measured by IOLMaster500 showed a higher RC compared with either SSOCTs (p < 0.002). Systematic difference was found in CCT and ACD between the two SSOCTs (p < 0.001), and in AL between ANTERION and IOLMaster500 (p < 0.001), with a mean difference of 1.6 µm, 0.022 mm and 0.021 mm, respectively. Both SSOCTs demonstrated smaller test–retest variability for measuring ACD and AL compared with IOLMaster500. There were significant disagreement in keratometry and AL measurements between the SSOCTs and PCI-based device; their measurements should not be considered as interchangeable.
format article
author Tommy C. Y. Chan
Marco C. Y. Yu
Vivian Chiu
Gilda Lai
Christopher K. S. Leung
Poemen P. M. Chan
author_facet Tommy C. Y. Chan
Marco C. Y. Yu
Vivian Chiu
Gilda Lai
Christopher K. S. Leung
Poemen P. M. Chan
author_sort Tommy C. Y. Chan
title Comparison of two novel swept-source optical coherence tomography devices to a partial coherence interferometry-based biometer
title_short Comparison of two novel swept-source optical coherence tomography devices to a partial coherence interferometry-based biometer
title_full Comparison of two novel swept-source optical coherence tomography devices to a partial coherence interferometry-based biometer
title_fullStr Comparison of two novel swept-source optical coherence tomography devices to a partial coherence interferometry-based biometer
title_full_unstemmed Comparison of two novel swept-source optical coherence tomography devices to a partial coherence interferometry-based biometer
title_sort comparison of two novel swept-source optical coherence tomography devices to a partial coherence interferometry-based biometer
publisher Nature Portfolio
publishDate 2021
url https://doaj.org/article/9ad3f244fc7a4143bacc46f2bc9dd2f2
work_keys_str_mv AT tommycychan comparisonoftwonovelsweptsourceopticalcoherencetomographydevicestoapartialcoherenceinterferometrybasedbiometer
AT marcocyyu comparisonoftwonovelsweptsourceopticalcoherencetomographydevicestoapartialcoherenceinterferometrybasedbiometer
AT vivianchiu comparisonoftwonovelsweptsourceopticalcoherencetomographydevicestoapartialcoherenceinterferometrybasedbiometer
AT gildalai comparisonoftwonovelsweptsourceopticalcoherencetomographydevicestoapartialcoherenceinterferometrybasedbiometer
AT christopherksleung comparisonoftwonovelsweptsourceopticalcoherencetomographydevicestoapartialcoherenceinterferometrybasedbiometer
AT poemenpmchan comparisonoftwonovelsweptsourceopticalcoherencetomographydevicestoapartialcoherenceinterferometrybasedbiometer
_version_ 1718384245861253120