Tube shunt coverage with gamma-irradiated cornea allograft (VisionGraft)

Feyzahan Ekici, Marlene R Moster, Victor Cvintal, Wanda D Hu, Michael Waisbourd Glaucoma Research Center, Wills Eye Hospital, Philadelphia, PA, USA Purpose: To investigate the clinical outcomes of tube shunt coverage using sterile gamma-irradiated cornea allograft.Patients and methods: The Wills E...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Ekici F, Moster MR, Cvintal V, Hu WD, Waisbourd M
Formato: article
Lenguaje:EN
Publicado: Dove Medical Press 2015
Materias:
Acceso en línea:https://doaj.org/article/9b02e94200bf4ec8bfbc6273c9f2a88e
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:9b02e94200bf4ec8bfbc6273c9f2a88e
record_format dspace
spelling oai:doaj.org-article:9b02e94200bf4ec8bfbc6273c9f2a88e2021-12-02T06:26:04ZTube shunt coverage with gamma-irradiated cornea allograft (VisionGraft)1177-5483https://doaj.org/article/9b02e94200bf4ec8bfbc6273c9f2a88e2015-04-01T00:00:00Zhttp://www.dovepress.com/tube-shunt-coverage-with-gamma-irradiated-cornea-allograft-visiongraft-peer-reviewed-article-OPTHhttps://doaj.org/toc/1177-5483Feyzahan Ekici, Marlene R Moster, Victor Cvintal, Wanda D Hu, Michael Waisbourd Glaucoma Research Center, Wills Eye Hospital, Philadelphia, PA, USA Purpose: To investigate the clinical outcomes of tube shunt coverage using sterile gamma-irradiated cornea allograft.Patients and methods: The Wills Eye Hospital Glaucoma Research Center retrospectively reviewed the medical records of 165 patients who underwent glaucoma tube shunt procedures using sterile gamma-irradiated cornea allograft (VisionGraft) between December 2012 and November 2013. Demographic characteristics, type of tube shunt, and position were noted. Complications were recorded at 1 day; 1 week; 1, 3, 6, and 12 months; and on the final postoperative visit.Results: One hundred and sixty-nine eyes of 165 patients were included. The mean follow-up time was 4.8±3.5 (ranging from 1 to 16) months. There was no evidence of immunological reaction, infection, or exposure in 166 eyes (98.2%). Three eyes (1.8%) experienced graft or tube exposure within the first 3 postoperative months. Two of the cases had underlying diseases: bullous pemphigoid and chronic allergic conjunctivitis.Conclusion: Coverage of tube shunts using gamma-irradiated cornea allograft had a low exposure rate and was well tolerated. The graft can be stored long term at room temperature and has an excellent postoperative cosmetic appearance.Keywords: aqueous shunts, gamma-irradiated cornea allograft, glaucoma drainage device, tube shunt surgery Ekici FMoster MRCvintal VHu WDWaisbourd MDove Medical PressarticleOphthalmologyRE1-994ENClinical Ophthalmology, Vol 2015, Iss default, Pp 751-755 (2015)
institution DOAJ
collection DOAJ
language EN
topic Ophthalmology
RE1-994
spellingShingle Ophthalmology
RE1-994
Ekici F
Moster MR
Cvintal V
Hu WD
Waisbourd M
Tube shunt coverage with gamma-irradiated cornea allograft (VisionGraft)
description Feyzahan Ekici, Marlene R Moster, Victor Cvintal, Wanda D Hu, Michael Waisbourd Glaucoma Research Center, Wills Eye Hospital, Philadelphia, PA, USA Purpose: To investigate the clinical outcomes of tube shunt coverage using sterile gamma-irradiated cornea allograft.Patients and methods: The Wills Eye Hospital Glaucoma Research Center retrospectively reviewed the medical records of 165 patients who underwent glaucoma tube shunt procedures using sterile gamma-irradiated cornea allograft (VisionGraft) between December 2012 and November 2013. Demographic characteristics, type of tube shunt, and position were noted. Complications were recorded at 1 day; 1 week; 1, 3, 6, and 12 months; and on the final postoperative visit.Results: One hundred and sixty-nine eyes of 165 patients were included. The mean follow-up time was 4.8±3.5 (ranging from 1 to 16) months. There was no evidence of immunological reaction, infection, or exposure in 166 eyes (98.2%). Three eyes (1.8%) experienced graft or tube exposure within the first 3 postoperative months. Two of the cases had underlying diseases: bullous pemphigoid and chronic allergic conjunctivitis.Conclusion: Coverage of tube shunts using gamma-irradiated cornea allograft had a low exposure rate and was well tolerated. The graft can be stored long term at room temperature and has an excellent postoperative cosmetic appearance.Keywords: aqueous shunts, gamma-irradiated cornea allograft, glaucoma drainage device, tube shunt surgery 
format article
author Ekici F
Moster MR
Cvintal V
Hu WD
Waisbourd M
author_facet Ekici F
Moster MR
Cvintal V
Hu WD
Waisbourd M
author_sort Ekici F
title Tube shunt coverage with gamma-irradiated cornea allograft (VisionGraft)
title_short Tube shunt coverage with gamma-irradiated cornea allograft (VisionGraft)
title_full Tube shunt coverage with gamma-irradiated cornea allograft (VisionGraft)
title_fullStr Tube shunt coverage with gamma-irradiated cornea allograft (VisionGraft)
title_full_unstemmed Tube shunt coverage with gamma-irradiated cornea allograft (VisionGraft)
title_sort tube shunt coverage with gamma-irradiated cornea allograft (visiongraft)
publisher Dove Medical Press
publishDate 2015
url https://doaj.org/article/9b02e94200bf4ec8bfbc6273c9f2a88e
work_keys_str_mv AT ekicif tubeshuntcoveragewithgammairradiatedcorneaallograftvisiongraft
AT mostermr tubeshuntcoveragewithgammairradiatedcorneaallograftvisiongraft
AT cvintalv tubeshuntcoveragewithgammairradiatedcorneaallograftvisiongraft
AT huwd tubeshuntcoveragewithgammairradiatedcorneaallograftvisiongraft
AT waisbourdm tubeshuntcoveragewithgammairradiatedcorneaallograftvisiongraft
_version_ 1718399952398319616