Tube shunt coverage with gamma-irradiated cornea allograft (VisionGraft)
Feyzahan Ekici, Marlene R Moster, Victor Cvintal, Wanda D Hu, Michael Waisbourd Glaucoma Research Center, Wills Eye Hospital, Philadelphia, PA, USA Purpose: To investigate the clinical outcomes of tube shunt coverage using sterile gamma-irradiated cornea allograft.Patients and methods: The Wills E...
Guardado en:
Autores principales: | , , , , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
Dove Medical Press
2015
|
Materias: | |
Acceso en línea: | https://doaj.org/article/9b02e94200bf4ec8bfbc6273c9f2a88e |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:9b02e94200bf4ec8bfbc6273c9f2a88e |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:9b02e94200bf4ec8bfbc6273c9f2a88e2021-12-02T06:26:04ZTube shunt coverage with gamma-irradiated cornea allograft (VisionGraft)1177-5483https://doaj.org/article/9b02e94200bf4ec8bfbc6273c9f2a88e2015-04-01T00:00:00Zhttp://www.dovepress.com/tube-shunt-coverage-with-gamma-irradiated-cornea-allograft-visiongraft-peer-reviewed-article-OPTHhttps://doaj.org/toc/1177-5483Feyzahan Ekici, Marlene R Moster, Victor Cvintal, Wanda D Hu, Michael Waisbourd Glaucoma Research Center, Wills Eye Hospital, Philadelphia, PA, USA Purpose: To investigate the clinical outcomes of tube shunt coverage using sterile gamma-irradiated cornea allograft.Patients and methods: The Wills Eye Hospital Glaucoma Research Center retrospectively reviewed the medical records of 165 patients who underwent glaucoma tube shunt procedures using sterile gamma-irradiated cornea allograft (VisionGraft) between December 2012 and November 2013. Demographic characteristics, type of tube shunt, and position were noted. Complications were recorded at 1 day; 1 week; 1, 3, 6, and 12 months; and on the final postoperative visit.Results: One hundred and sixty-nine eyes of 165 patients were included. The mean follow-up time was 4.8±3.5 (ranging from 1 to 16) months. There was no evidence of immunological reaction, infection, or exposure in 166 eyes (98.2%). Three eyes (1.8%) experienced graft or tube exposure within the first 3 postoperative months. Two of the cases had underlying diseases: bullous pemphigoid and chronic allergic conjunctivitis.Conclusion: Coverage of tube shunts using gamma-irradiated cornea allograft had a low exposure rate and was well tolerated. The graft can be stored long term at room temperature and has an excellent postoperative cosmetic appearance.Keywords: aqueous shunts, gamma-irradiated cornea allograft, glaucoma drainage device, tube shunt surgery Ekici FMoster MRCvintal VHu WDWaisbourd MDove Medical PressarticleOphthalmologyRE1-994ENClinical Ophthalmology, Vol 2015, Iss default, Pp 751-755 (2015) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
Ophthalmology RE1-994 |
spellingShingle |
Ophthalmology RE1-994 Ekici F Moster MR Cvintal V Hu WD Waisbourd M Tube shunt coverage with gamma-irradiated cornea allograft (VisionGraft) |
description |
Feyzahan Ekici, Marlene R Moster, Victor Cvintal, Wanda D Hu, Michael Waisbourd Glaucoma Research Center, Wills Eye Hospital, Philadelphia, PA, USA Purpose: To investigate the clinical outcomes of tube shunt coverage using sterile gamma-irradiated cornea allograft.Patients and methods: The Wills Eye Hospital Glaucoma Research Center retrospectively reviewed the medical records of 165 patients who underwent glaucoma tube shunt procedures using sterile gamma-irradiated cornea allograft (VisionGraft) between December 2012 and November 2013. Demographic characteristics, type of tube shunt, and position were noted. Complications were recorded at 1 day; 1 week; 1, 3, 6, and 12 months; and on the final postoperative visit.Results: One hundred and sixty-nine eyes of 165 patients were included. The mean follow-up time was 4.8±3.5 (ranging from 1 to 16) months. There was no evidence of immunological reaction, infection, or exposure in 166 eyes (98.2%). Three eyes (1.8%) experienced graft or tube exposure within the first 3 postoperative months. Two of the cases had underlying diseases: bullous pemphigoid and chronic allergic conjunctivitis.Conclusion: Coverage of tube shunts using gamma-irradiated cornea allograft had a low exposure rate and was well tolerated. The graft can be stored long term at room temperature and has an excellent postoperative cosmetic appearance.Keywords: aqueous shunts, gamma-irradiated cornea allograft, glaucoma drainage device, tube shunt surgery |
format |
article |
author |
Ekici F Moster MR Cvintal V Hu WD Waisbourd M |
author_facet |
Ekici F Moster MR Cvintal V Hu WD Waisbourd M |
author_sort |
Ekici F |
title |
Tube shunt coverage with gamma-irradiated cornea allograft (VisionGraft) |
title_short |
Tube shunt coverage with gamma-irradiated cornea allograft (VisionGraft) |
title_full |
Tube shunt coverage with gamma-irradiated cornea allograft (VisionGraft) |
title_fullStr |
Tube shunt coverage with gamma-irradiated cornea allograft (VisionGraft) |
title_full_unstemmed |
Tube shunt coverage with gamma-irradiated cornea allograft (VisionGraft) |
title_sort |
tube shunt coverage with gamma-irradiated cornea allograft (visiongraft) |
publisher |
Dove Medical Press |
publishDate |
2015 |
url |
https://doaj.org/article/9b02e94200bf4ec8bfbc6273c9f2a88e |
work_keys_str_mv |
AT ekicif tubeshuntcoveragewithgammairradiatedcorneaallograftvisiongraft AT mostermr tubeshuntcoveragewithgammairradiatedcorneaallograftvisiongraft AT cvintalv tubeshuntcoveragewithgammairradiatedcorneaallograftvisiongraft AT huwd tubeshuntcoveragewithgammairradiatedcorneaallograftvisiongraft AT waisbourdm tubeshuntcoveragewithgammairradiatedcorneaallograftvisiongraft |
_version_ |
1718399952398319616 |