Visual perception changes and optical stability after intracorneal ring segment implantation: comparison between 3 months and 1 year after surgery
Juliane de Freitas Santos Paranhos, Marcos Pereira Ávila, Augusto Paranhos Jr, Paulo SchorFederal University of São Paulo, São Paulo, BrazilPurpose: To prospectively evaluate intracorneal ring segment (ICRS) implantation on quality of life (QoL) of patien...
Guardado en:
Autores principales: | , , , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
Dove Medical Press
2011
|
Materias: | |
Acceso en línea: | https://doaj.org/article/9bb64a431d3948438c7dd987ea78c426 |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:9bb64a431d3948438c7dd987ea78c426 |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:9bb64a431d3948438c7dd987ea78c4262021-12-02T01:02:08ZVisual perception changes and optical stability after intracorneal ring segment implantation: comparison between 3 months and 1 year after surgery1177-54671177-5483https://doaj.org/article/9bb64a431d3948438c7dd987ea78c4262011-07-01T00:00:00Zhttp://www.dovepress.com/visual-perception-changes-and-optical-stability-after-intracorneal-rin-a7989https://doaj.org/toc/1177-5467https://doaj.org/toc/1177-5483Juliane de Freitas Santos Paranhos, Marcos Pereira Ávila, Augusto Paranhos Jr, Paulo SchorFederal University of São Paulo, São Paulo, BrazilPurpose: To prospectively evaluate intracorneal ring segment (ICRS) implantation on quality of life (QoL) of patients with keratoconus changes and identify factors responsible.Methods: Sixty-nine eyes of 42 keratoconus patients were implanted with the Keraring (Mediphacos, Belo Horizonte, Brazil). Best corrected visual acuity (BCVA), refraction, and steep keratometry were analyzed 3 months and 1 year after surgery. All patients self-administered the National Eye Institute Refractive Error Quality of life instrument at 2 time points: after having worn best correction for at least 30 days since evaluation (mean 4 months after surgery) and 1 year after surgery. To analyze if the use of the appropriate correction at 1 year follow up had any impact on visual acuity and V-QoL, patients were divided into 2 groups: group A (appropriate correction) and B (not appropriate correction).Results: After 1 year, QoL changes related to scales ‘clarity of vision’, ‘near vision’, and ‘far vision’. Keratometric values, sphere, and spherical equivalent did not differ significantly between 3 months and 1 year postoperative. Cylinder increase was statistically but not clinically significant. Binocular BCVA did not change 1 year after surgery in group A and showed a clinically significant impairment in group B. A year after surgery, 18 patients did not use correction suggested by a physician 3 months after surgery. QoL was not statistically different 1 year after surgery between group A and group B.Conclusion: Our findings show that the way keratoconic patients see is difficult to analyze using only quantitative and 1-visit metrics. They highlight the importance of patients’ self perception and performing longitudinal analysis to consider neural compensation to optical changes from surgery.Keywords: keratoconus, cornea, quality of life Paranhos JFSPereira Ávila MParanhos-Jr ASchor PDove Medical PressarticleOphthalmologyRE1-994ENClinical Ophthalmology, Vol 2011, Iss default, Pp 1057-1062 (2011) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
Ophthalmology RE1-994 |
spellingShingle |
Ophthalmology RE1-994 Paranhos JFS Pereira Ávila M Paranhos-Jr A Schor P Visual perception changes and optical stability after intracorneal ring segment implantation: comparison between 3 months and 1 year after surgery |
description |
Juliane de Freitas Santos Paranhos, Marcos Pereira Ávila, Augusto Paranhos Jr, Paulo SchorFederal University of São Paulo, São Paulo, BrazilPurpose: To prospectively evaluate intracorneal ring segment (ICRS) implantation on quality of life (QoL) of patients with keratoconus changes and identify factors responsible.Methods: Sixty-nine eyes of 42 keratoconus patients were implanted with the Keraring (Mediphacos, Belo Horizonte, Brazil). Best corrected visual acuity (BCVA), refraction, and steep keratometry were analyzed 3 months and 1 year after surgery. All patients self-administered the National Eye Institute Refractive Error Quality of life instrument at 2 time points: after having worn best correction for at least 30 days since evaluation (mean 4 months after surgery) and 1 year after surgery. To analyze if the use of the appropriate correction at 1 year follow up had any impact on visual acuity and V-QoL, patients were divided into 2 groups: group A (appropriate correction) and B (not appropriate correction).Results: After 1 year, QoL changes related to scales ‘clarity of vision’, ‘near vision’, and ‘far vision’. Keratometric values, sphere, and spherical equivalent did not differ significantly between 3 months and 1 year postoperative. Cylinder increase was statistically but not clinically significant. Binocular BCVA did not change 1 year after surgery in group A and showed a clinically significant impairment in group B. A year after surgery, 18 patients did not use correction suggested by a physician 3 months after surgery. QoL was not statistically different 1 year after surgery between group A and group B.Conclusion: Our findings show that the way keratoconic patients see is difficult to analyze using only quantitative and 1-visit metrics. They highlight the importance of patients’ self perception and performing longitudinal analysis to consider neural compensation to optical changes from surgery.Keywords: keratoconus, cornea, quality of life  |
format |
article |
author |
Paranhos JFS Pereira Ávila M Paranhos-Jr A Schor P |
author_facet |
Paranhos JFS Pereira Ávila M Paranhos-Jr A Schor P |
author_sort |
Paranhos JFS |
title |
Visual perception changes and optical stability after intracorneal ring segment implantation: comparison between 3 months and 1 year after surgery |
title_short |
Visual perception changes and optical stability after intracorneal ring segment implantation: comparison between 3 months and 1 year after surgery |
title_full |
Visual perception changes and optical stability after intracorneal ring segment implantation: comparison between 3 months and 1 year after surgery |
title_fullStr |
Visual perception changes and optical stability after intracorneal ring segment implantation: comparison between 3 months and 1 year after surgery |
title_full_unstemmed |
Visual perception changes and optical stability after intracorneal ring segment implantation: comparison between 3 months and 1 year after surgery |
title_sort |
visual perception changes and optical stability after intracorneal ring segment implantation: comparison between 3 months and 1 year after surgery |
publisher |
Dove Medical Press |
publishDate |
2011 |
url |
https://doaj.org/article/9bb64a431d3948438c7dd987ea78c426 |
work_keys_str_mv |
AT paranhosjfs visualperceptionchangesandopticalstabilityafterintracornealringsegmentimplantationcomparisonbetween3monthsand1yearaftersurgery AT pereiraampaacutevilam visualperceptionchangesandopticalstabilityafterintracornealringsegmentimplantationcomparisonbetween3monthsand1yearaftersurgery AT paranhosjra visualperceptionchangesandopticalstabilityafterintracornealringsegmentimplantationcomparisonbetween3monthsand1yearaftersurgery AT schorp visualperceptionchangesandopticalstabilityafterintracornealringsegmentimplantationcomparisonbetween3monthsand1yearaftersurgery |
_version_ |
1718403335283802112 |