Analysis of transient recovery voltage and secondary arc current in transposed extra-high voltage lines in a two-phase auto-reclosing

Extra-high voltage (EHV) lines of 500–750 kV, providing transmission of electricity over long distances and at the same time performing the functions of intersystem communication at the level of the national power system, play an important role not only in normal modes, but also in emergency modes,...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Karomatullo Makhmudov, Tatyana Krasilnikova, Murodbek Safaraliev, Sergey Kokin, Anvari Ghulomzoda, Stepan Dmitriev
Formato: article
Lenguaje:EN
Publicado: Elsevier 2021
Materias:
Acceso en línea:https://doaj.org/article/9bf139ca704d4bb682ce2ceee99f3639
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:9bf139ca704d4bb682ce2ceee99f3639
record_format dspace
spelling oai:doaj.org-article:9bf139ca704d4bb682ce2ceee99f36392021-11-26T04:34:12ZAnalysis of transient recovery voltage and secondary arc current in transposed extra-high voltage lines in a two-phase auto-reclosing2352-484710.1016/j.egyr.2021.08.138https://doaj.org/article/9bf139ca704d4bb682ce2ceee99f36392021-11-01T00:00:00Zhttp://www.sciencedirect.com/science/article/pii/S2352484721007411https://doaj.org/toc/2352-4847Extra-high voltage (EHV) lines of 500–750 kV, providing transmission of electricity over long distances and at the same time performing the functions of intersystem communication at the level of the national power system, play an important role not only in normal modes, but also in emergency modes, ensuring the dynamic stability of the power system as a whole. In these lines, the overwhelming proportion of power cuts are caused by single-phase short circuits (90%), a significant part of which, being unstable arc faults, are successfully eliminated in the single-phase auto-reclosing cycle. Also, about 5%–10% of failures can be constituted by two-phase short circuits, which can be eliminated in a two-phase auto-reclosing cycle (TPhAR). The purpose of this paper is to study two-phase auto-reclosing in transposed EHV lines equipped with four-radial shunt reactors (ShR). The paper analyzes the efficiency of using a two-phase auto-reclosing to eliminate two-phase short-circuits in the lines connecting the power systems of Kyrgyzstan and Tajikistan. An algorithm is proposed for calculating the transient recovering voltages (TRV) and secondary arc currents (SAC) in the real transposed line Datka–Khujand–Dushanbe. The obtained results of TRV and SAC, which are within the permissible limits for the Dushanbe–Khujand line section, make it possible to have a dead time of TPhAR of no more than 0.6 s, in order to maintain the dynamic stability of the power system. For lines with a length of about 500 km (Datka–Khujand), equipped with three reactors, a successful TPhAR is impossible due to the appearance of resonant TRV in the circuit. The paper proposes the use of banks of capacitors connected in series in the phases of the ShR for the implementation of a successful TPhAR with the duration of the required pause of about 0.6 s.Karomatullo MakhmudovTatyana KrasilnikovaMurodbek SafaralievSergey KokinAnvari GhulomzodaStepan DmitrievElsevierarticleExtra-high voltage lineTransposed lineFour-radial shunt reactorsTwo-phase auto-reclosingTransient recovery voltageSecondary arc currentElectrical engineering. Electronics. Nuclear engineeringTK1-9971ENEnergy Reports, Vol 7, Iss , Pp 56-64 (2021)
institution DOAJ
collection DOAJ
language EN
topic Extra-high voltage line
Transposed line
Four-radial shunt reactors
Two-phase auto-reclosing
Transient recovery voltage
Secondary arc current
Electrical engineering. Electronics. Nuclear engineering
TK1-9971
spellingShingle Extra-high voltage line
Transposed line
Four-radial shunt reactors
Two-phase auto-reclosing
Transient recovery voltage
Secondary arc current
Electrical engineering. Electronics. Nuclear engineering
TK1-9971
Karomatullo Makhmudov
Tatyana Krasilnikova
Murodbek Safaraliev
Sergey Kokin
Anvari Ghulomzoda
Stepan Dmitriev
Analysis of transient recovery voltage and secondary arc current in transposed extra-high voltage lines in a two-phase auto-reclosing
description Extra-high voltage (EHV) lines of 500–750 kV, providing transmission of electricity over long distances and at the same time performing the functions of intersystem communication at the level of the national power system, play an important role not only in normal modes, but also in emergency modes, ensuring the dynamic stability of the power system as a whole. In these lines, the overwhelming proportion of power cuts are caused by single-phase short circuits (90%), a significant part of which, being unstable arc faults, are successfully eliminated in the single-phase auto-reclosing cycle. Also, about 5%–10% of failures can be constituted by two-phase short circuits, which can be eliminated in a two-phase auto-reclosing cycle (TPhAR). The purpose of this paper is to study two-phase auto-reclosing in transposed EHV lines equipped with four-radial shunt reactors (ShR). The paper analyzes the efficiency of using a two-phase auto-reclosing to eliminate two-phase short-circuits in the lines connecting the power systems of Kyrgyzstan and Tajikistan. An algorithm is proposed for calculating the transient recovering voltages (TRV) and secondary arc currents (SAC) in the real transposed line Datka–Khujand–Dushanbe. The obtained results of TRV and SAC, which are within the permissible limits for the Dushanbe–Khujand line section, make it possible to have a dead time of TPhAR of no more than 0.6 s, in order to maintain the dynamic stability of the power system. For lines with a length of about 500 km (Datka–Khujand), equipped with three reactors, a successful TPhAR is impossible due to the appearance of resonant TRV in the circuit. The paper proposes the use of banks of capacitors connected in series in the phases of the ShR for the implementation of a successful TPhAR with the duration of the required pause of about 0.6 s.
format article
author Karomatullo Makhmudov
Tatyana Krasilnikova
Murodbek Safaraliev
Sergey Kokin
Anvari Ghulomzoda
Stepan Dmitriev
author_facet Karomatullo Makhmudov
Tatyana Krasilnikova
Murodbek Safaraliev
Sergey Kokin
Anvari Ghulomzoda
Stepan Dmitriev
author_sort Karomatullo Makhmudov
title Analysis of transient recovery voltage and secondary arc current in transposed extra-high voltage lines in a two-phase auto-reclosing
title_short Analysis of transient recovery voltage and secondary arc current in transposed extra-high voltage lines in a two-phase auto-reclosing
title_full Analysis of transient recovery voltage and secondary arc current in transposed extra-high voltage lines in a two-phase auto-reclosing
title_fullStr Analysis of transient recovery voltage and secondary arc current in transposed extra-high voltage lines in a two-phase auto-reclosing
title_full_unstemmed Analysis of transient recovery voltage and secondary arc current in transposed extra-high voltage lines in a two-phase auto-reclosing
title_sort analysis of transient recovery voltage and secondary arc current in transposed extra-high voltage lines in a two-phase auto-reclosing
publisher Elsevier
publishDate 2021
url https://doaj.org/article/9bf139ca704d4bb682ce2ceee99f3639
work_keys_str_mv AT karomatullomakhmudov analysisoftransientrecoveryvoltageandsecondaryarccurrentintransposedextrahighvoltagelinesinatwophaseautoreclosing
AT tatyanakrasilnikova analysisoftransientrecoveryvoltageandsecondaryarccurrentintransposedextrahighvoltagelinesinatwophaseautoreclosing
AT murodbeksafaraliev analysisoftransientrecoveryvoltageandsecondaryarccurrentintransposedextrahighvoltagelinesinatwophaseautoreclosing
AT sergeykokin analysisoftransientrecoveryvoltageandsecondaryarccurrentintransposedextrahighvoltagelinesinatwophaseautoreclosing
AT anvarighulomzoda analysisoftransientrecoveryvoltageandsecondaryarccurrentintransposedextrahighvoltagelinesinatwophaseautoreclosing
AT stepandmitriev analysisoftransientrecoveryvoltageandsecondaryarccurrentintransposedextrahighvoltagelinesinatwophaseautoreclosing
_version_ 1718409857132920832