MR scanner systems should be adequately characterized in diffusion-MRI of the breast.

Breast imaging represents a relatively recent and promising field of application of quantitative diffusion-MRI techniques. In view of the importance of guaranteeing and assessing its reliability in clinical as well as research settings, the aim of this study was to specifically characterize how the...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Marco Giannelli, Roberto Sghedoni, Chiara Iacconi, Mauro Iori, Antonio Claudio Traino, Maria Guerrisi, Mario Mascalchi, Nicola Toschi, Stefano Diciotti
Formato: article
Lenguaje:EN
Publicado: Public Library of Science (PLoS) 2014
Materias:
R
Q
Acceso en línea:https://doaj.org/article/9c27cd17fd454e49bfa35946a4b9527c
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:9c27cd17fd454e49bfa35946a4b9527c
record_format dspace
spelling oai:doaj.org-article:9c27cd17fd454e49bfa35946a4b9527c2021-11-18T08:35:25ZMR scanner systems should be adequately characterized in diffusion-MRI of the breast.1932-620310.1371/journal.pone.0086280https://doaj.org/article/9c27cd17fd454e49bfa35946a4b9527c2014-01-01T00:00:00Zhttps://www.ncbi.nlm.nih.gov/pmc/articles/pmid/24489711/pdf/?tool=EBIhttps://doaj.org/toc/1932-6203Breast imaging represents a relatively recent and promising field of application of quantitative diffusion-MRI techniques. In view of the importance of guaranteeing and assessing its reliability in clinical as well as research settings, the aim of this study was to specifically characterize how the main MR scanner system-related factors affect quantitative measurements in diffusion-MRI of the breast. In particular, phantom acquisitions were performed on three 1.5 T MR scanner systems by different manufacturers, all equipped with a dedicated multi-channel breast coil as well as acquisition sequences for diffusion-MRI of the breast. We assessed the accuracy, inter-scan and inter-scanner reproducibility of the mean apparent diffusion coefficient measured along the main orthogonal directions (<ADC>) as well as of diffusion-tensor imaging (DTI)-derived mean diffusivity (MD) measurements. Additionally, we estimated spatial non-uniformity of <ADC> (NU<ADC>) and MD (NUMD) maps. We showed that the signal-to-noise ratio as well as overall calibration of high strength diffusion gradients system in typical acquisition sequences for diffusion-MRI of the breast varied across MR scanner systems, introducing systematic bias in the measurements of diffusion indices. While <ADC> and MD values were not appreciably different from each other, they substantially varied across MR scanner systems. The mean of the accuracies of measured <ADC> and MD was in the range [-2.3%,11.9%], and the mean of the coefficients of variation for <ADC> and MD measurements across MR scanner systems was 6.8%. The coefficient of variation for repeated measurements of both <ADC> and MD was < 1%, while NU<ADC> and NUMD values were <4%. Our results highlight that MR scanner system-related factors can substantially affect quantitative diffusion-MRI of the breast. Therefore, a specific quality control program for assessing and monitoring the performance of MR scanner systems for diffusion-MRI of the breast is highly recommended at every site, especially in multicenter and longitudinal studies.Marco GiannelliRoberto SghedoniChiara IacconiMauro IoriAntonio Claudio TrainoMaria GuerrisiMario MascalchiNicola ToschiStefano DiciottiPublic Library of Science (PLoS)articleMedicineRScienceQENPLoS ONE, Vol 9, Iss 1, p e86280 (2014)
institution DOAJ
collection DOAJ
language EN
topic Medicine
R
Science
Q
spellingShingle Medicine
R
Science
Q
Marco Giannelli
Roberto Sghedoni
Chiara Iacconi
Mauro Iori
Antonio Claudio Traino
Maria Guerrisi
Mario Mascalchi
Nicola Toschi
Stefano Diciotti
MR scanner systems should be adequately characterized in diffusion-MRI of the breast.
description Breast imaging represents a relatively recent and promising field of application of quantitative diffusion-MRI techniques. In view of the importance of guaranteeing and assessing its reliability in clinical as well as research settings, the aim of this study was to specifically characterize how the main MR scanner system-related factors affect quantitative measurements in diffusion-MRI of the breast. In particular, phantom acquisitions were performed on three 1.5 T MR scanner systems by different manufacturers, all equipped with a dedicated multi-channel breast coil as well as acquisition sequences for diffusion-MRI of the breast. We assessed the accuracy, inter-scan and inter-scanner reproducibility of the mean apparent diffusion coefficient measured along the main orthogonal directions (<ADC>) as well as of diffusion-tensor imaging (DTI)-derived mean diffusivity (MD) measurements. Additionally, we estimated spatial non-uniformity of <ADC> (NU<ADC>) and MD (NUMD) maps. We showed that the signal-to-noise ratio as well as overall calibration of high strength diffusion gradients system in typical acquisition sequences for diffusion-MRI of the breast varied across MR scanner systems, introducing systematic bias in the measurements of diffusion indices. While <ADC> and MD values were not appreciably different from each other, they substantially varied across MR scanner systems. The mean of the accuracies of measured <ADC> and MD was in the range [-2.3%,11.9%], and the mean of the coefficients of variation for <ADC> and MD measurements across MR scanner systems was 6.8%. The coefficient of variation for repeated measurements of both <ADC> and MD was < 1%, while NU<ADC> and NUMD values were <4%. Our results highlight that MR scanner system-related factors can substantially affect quantitative diffusion-MRI of the breast. Therefore, a specific quality control program for assessing and monitoring the performance of MR scanner systems for diffusion-MRI of the breast is highly recommended at every site, especially in multicenter and longitudinal studies.
format article
author Marco Giannelli
Roberto Sghedoni
Chiara Iacconi
Mauro Iori
Antonio Claudio Traino
Maria Guerrisi
Mario Mascalchi
Nicola Toschi
Stefano Diciotti
author_facet Marco Giannelli
Roberto Sghedoni
Chiara Iacconi
Mauro Iori
Antonio Claudio Traino
Maria Guerrisi
Mario Mascalchi
Nicola Toschi
Stefano Diciotti
author_sort Marco Giannelli
title MR scanner systems should be adequately characterized in diffusion-MRI of the breast.
title_short MR scanner systems should be adequately characterized in diffusion-MRI of the breast.
title_full MR scanner systems should be adequately characterized in diffusion-MRI of the breast.
title_fullStr MR scanner systems should be adequately characterized in diffusion-MRI of the breast.
title_full_unstemmed MR scanner systems should be adequately characterized in diffusion-MRI of the breast.
title_sort mr scanner systems should be adequately characterized in diffusion-mri of the breast.
publisher Public Library of Science (PLoS)
publishDate 2014
url https://doaj.org/article/9c27cd17fd454e49bfa35946a4b9527c
work_keys_str_mv AT marcogiannelli mrscannersystemsshouldbeadequatelycharacterizedindiffusionmriofthebreast
AT robertosghedoni mrscannersystemsshouldbeadequatelycharacterizedindiffusionmriofthebreast
AT chiaraiacconi mrscannersystemsshouldbeadequatelycharacterizedindiffusionmriofthebreast
AT mauroiori mrscannersystemsshouldbeadequatelycharacterizedindiffusionmriofthebreast
AT antonioclaudiotraino mrscannersystemsshouldbeadequatelycharacterizedindiffusionmriofthebreast
AT mariaguerrisi mrscannersystemsshouldbeadequatelycharacterizedindiffusionmriofthebreast
AT mariomascalchi mrscannersystemsshouldbeadequatelycharacterizedindiffusionmriofthebreast
AT nicolatoschi mrscannersystemsshouldbeadequatelycharacterizedindiffusionmriofthebreast
AT stefanodiciotti mrscannersystemsshouldbeadequatelycharacterizedindiffusionmriofthebreast
_version_ 1718421577475817472