Comparative evaluation of toric intraocular lens alignment and visual quality with image-guided surgery and conventional three-step manual marking
Jeewan S Titiyal, Manpreet Kaur, Cijin P Jose, Ruchita Falera, Ashutosh Kinkar, Lalit MS Bageshwar Cornea, Cataract and Refractive Surgery Services, Dr Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi, India Purpose: To compare toric intraocular...
Guardado en:
Autores principales: | , , , , , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
Dove Medical Press
2018
|
Materias: | |
Acceso en línea: | https://doaj.org/article/9d02e374f1b64a9d9398510fbe0e26d8 |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:9d02e374f1b64a9d9398510fbe0e26d8 |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:9d02e374f1b64a9d9398510fbe0e26d82021-12-02T01:50:32ZComparative evaluation of toric intraocular lens alignment and visual quality with image-guided surgery and conventional three-step manual marking1177-5483https://doaj.org/article/9d02e374f1b64a9d9398510fbe0e26d82018-04-01T00:00:00Zhttps://www.dovepress.com/comparative-evaluation-of-toric-intraocular-lens-alignment-and-visual--peer-reviewed-article-OPTHhttps://doaj.org/toc/1177-5483Jeewan S Titiyal, Manpreet Kaur, Cijin P Jose, Ruchita Falera, Ashutosh Kinkar, Lalit MS Bageshwar Cornea, Cataract and Refractive Surgery Services, Dr Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi, India Purpose: To compare toric intraocular lens (IOL) alignment assisted by image-guided surgery or manual marking methods and its impact on visual quality. Patients and methods: This prospective comparative study enrolled 80 eyes with cataract and astigmatism ≥1.5 D to undergo phacoemulsification with toric IOL alignment by manual marking method using bubble marker (group I, n=40) or Callisto eye and Z align (group II, n=40). Postoperatively, accuracy of alignment and visual quality was assessed with a ray tracing aberrometer. Primary outcome measure was deviation from the target axis of implantation. Secondary outcome measures were visual quality and acuity. Follow-up was performed on postoperative days (PODs) 1 and 30. Results: Deviation from the target axis of implantation was significantly less in group II on PODs 1 and 30 (group I: 5.5°±3.3°, group II: 3.6°±2.6°; p=0.005). Postoperative refractive cylinder was -0.89±0.35 D in group I and -0.64±0.36 D in group II (p=0.003). Visual acuity was comparable between both the groups. Visual quality measured in terms of Strehl ratio (p<0.05) and modulation transfer function (MTF) (p<0.05) was significantly better in the image-guided surgery group. Significant negative correlation was observed between deviation from target axis and visual quality parameters (Strehl ratio and MTF) (p<0.05). Conclusion: Image-guided surgery allows precise alignment of toric IOL without need for reference marking. It is associated with superior visual quality which correlates with the precision of IOL alignment. Keywords: toric IOL alignment, image-guided surgery, manual marking toric IOL, Callisto eye and Z align toric IOL, visual quality toric IOL, visual quality image-guided surgeryTitiyal JSKaur MJose CPFalera RKinkar ABageshwar LMSDove Medical PressarticleToric IOL alignmentImage guided surgeryManual marking toric IOLCALLISTO Eye and Z align toric IOLOphthalmologyRE1-994ENClinical Ophthalmology, Vol Volume 12, Pp 747-753 (2018) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
Toric IOL alignment Image guided surgery Manual marking toric IOL CALLISTO Eye and Z align toric IOL Ophthalmology RE1-994 |
spellingShingle |
Toric IOL alignment Image guided surgery Manual marking toric IOL CALLISTO Eye and Z align toric IOL Ophthalmology RE1-994 Titiyal JS Kaur M Jose CP Falera R Kinkar A Bageshwar LMS Comparative evaluation of toric intraocular lens alignment and visual quality with image-guided surgery and conventional three-step manual marking |
description |
Jeewan S Titiyal, Manpreet Kaur, Cijin P Jose, Ruchita Falera, Ashutosh Kinkar, Lalit MS Bageshwar Cornea, Cataract and Refractive Surgery Services, Dr Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi, India Purpose: To compare toric intraocular lens (IOL) alignment assisted by image-guided surgery or manual marking methods and its impact on visual quality. Patients and methods: This prospective comparative study enrolled 80 eyes with cataract and astigmatism ≥1.5 D to undergo phacoemulsification with toric IOL alignment by manual marking method using bubble marker (group I, n=40) or Callisto eye and Z align (group II, n=40). Postoperatively, accuracy of alignment and visual quality was assessed with a ray tracing aberrometer. Primary outcome measure was deviation from the target axis of implantation. Secondary outcome measures were visual quality and acuity. Follow-up was performed on postoperative days (PODs) 1 and 30. Results: Deviation from the target axis of implantation was significantly less in group II on PODs 1 and 30 (group I: 5.5°±3.3°, group II: 3.6°±2.6°; p=0.005). Postoperative refractive cylinder was -0.89±0.35 D in group I and -0.64±0.36 D in group II (p=0.003). Visual acuity was comparable between both the groups. Visual quality measured in terms of Strehl ratio (p<0.05) and modulation transfer function (MTF) (p<0.05) was significantly better in the image-guided surgery group. Significant negative correlation was observed between deviation from target axis and visual quality parameters (Strehl ratio and MTF) (p<0.05). Conclusion: Image-guided surgery allows precise alignment of toric IOL without need for reference marking. It is associated with superior visual quality which correlates with the precision of IOL alignment. Keywords: toric IOL alignment, image-guided surgery, manual marking toric IOL, Callisto eye and Z align toric IOL, visual quality toric IOL, visual quality image-guided surgery |
format |
article |
author |
Titiyal JS Kaur M Jose CP Falera R Kinkar A Bageshwar LMS |
author_facet |
Titiyal JS Kaur M Jose CP Falera R Kinkar A Bageshwar LMS |
author_sort |
Titiyal JS |
title |
Comparative evaluation of toric intraocular lens alignment and visual quality with image-guided surgery and conventional three-step manual marking |
title_short |
Comparative evaluation of toric intraocular lens alignment and visual quality with image-guided surgery and conventional three-step manual marking |
title_full |
Comparative evaluation of toric intraocular lens alignment and visual quality with image-guided surgery and conventional three-step manual marking |
title_fullStr |
Comparative evaluation of toric intraocular lens alignment and visual quality with image-guided surgery and conventional three-step manual marking |
title_full_unstemmed |
Comparative evaluation of toric intraocular lens alignment and visual quality with image-guided surgery and conventional three-step manual marking |
title_sort |
comparative evaluation of toric intraocular lens alignment and visual quality with image-guided surgery and conventional three-step manual marking |
publisher |
Dove Medical Press |
publishDate |
2018 |
url |
https://doaj.org/article/9d02e374f1b64a9d9398510fbe0e26d8 |
work_keys_str_mv |
AT titiyaljs comparativeevaluationoftoricintraocularlensalignmentandvisualqualitywithimageguidedsurgeryandconventionalthreestepmanualmarking AT kaurm comparativeevaluationoftoricintraocularlensalignmentandvisualqualitywithimageguidedsurgeryandconventionalthreestepmanualmarking AT josecp comparativeevaluationoftoricintraocularlensalignmentandvisualqualitywithimageguidedsurgeryandconventionalthreestepmanualmarking AT falerar comparativeevaluationoftoricintraocularlensalignmentandvisualqualitywithimageguidedsurgeryandconventionalthreestepmanualmarking AT kinkara comparativeevaluationoftoricintraocularlensalignmentandvisualqualitywithimageguidedsurgeryandconventionalthreestepmanualmarking AT bageshwarlms comparativeevaluationoftoricintraocularlensalignmentandvisualqualitywithimageguidedsurgeryandconventionalthreestepmanualmarking |
_version_ |
1718402857234857984 |