Local compression fatigue property of roll core sandwich panel

When the honeycomb core sandwich panel (hereafter, HSP for brevity) is used as a floor panel, a dent is formed on the surface of it. If the depth of dent was deeper, it is changed into a new one. In order to change it efficiently, it is necessary to study a period for use as the floor panel applied...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Yukiyoshi KOBAYASHI, Yoshinao KISHIMOTO, Toshihisa OHTSUKA, Akira KARATSU
Formato: article
Lenguaje:EN
Publicado: The Japan Society of Mechanical Engineers 2014
Materias:
Acceso en línea:https://doaj.org/article/9e19024a7e24479aafcb183362026317
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:9e19024a7e24479aafcb183362026317
record_format dspace
spelling oai:doaj.org-article:9e19024a7e24479aafcb1833620263172021-11-26T06:16:58ZLocal compression fatigue property of roll core sandwich panel2187-974510.1299/mej.14-00322https://doaj.org/article/9e19024a7e24479aafcb1833620263172014-12-01T00:00:00Zhttps://www.jstage.jst.go.jp/article/mej/2/1/2_14-00322/_pdf/-char/enhttps://doaj.org/toc/2187-9745When the honeycomb core sandwich panel (hereafter, HSP for brevity) is used as a floor panel, a dent is formed on the surface of it. If the depth of dent was deeper, it is changed into a new one. In order to change it efficiently, it is necessary to study a period for use as the floor panel applied the repetition of local compression load for the longitudinal direction of honeycomb core (hereafter, fatigue life for brevity). The local compression fatigue tests of peripherally clamped HSPs were carried out. In this study, it is attempted to clarify the local compression fatigue property of roll core sandwich panel which was superior to the honeycomb core sandwich panel in the manufacturing cost and the mechanical property. From the obtained results, the follows were summarized; 1) There were three fracture patterns such as a tensile and a shearing types that fractured on the border of the indenter contact region and the noncontact region of specimen and a shearing around dent type that fractured on the periphery of a dent formed during the indentation. 2) The stress state at a crack initiation site governed a fatigue life. 3) Not a core shape but a cell size influenced the fatigue life.Yukiyoshi KOBAYASHIYoshinao KISHIMOTOToshihisa OHTSUKAAkira KARATSUThe Japan Society of Mechanical Engineersarticlefatiguelaminated constructionstructural mechanicsdesignsandwich panelMechanical engineering and machineryTJ1-1570ENMechanical Engineering Journal, Vol 2, Iss 1, Pp 14-00322-14-00322 (2014)
institution DOAJ
collection DOAJ
language EN
topic fatigue
laminated construction
structural mechanics
design
sandwich panel
Mechanical engineering and machinery
TJ1-1570
spellingShingle fatigue
laminated construction
structural mechanics
design
sandwich panel
Mechanical engineering and machinery
TJ1-1570
Yukiyoshi KOBAYASHI
Yoshinao KISHIMOTO
Toshihisa OHTSUKA
Akira KARATSU
Local compression fatigue property of roll core sandwich panel
description When the honeycomb core sandwich panel (hereafter, HSP for brevity) is used as a floor panel, a dent is formed on the surface of it. If the depth of dent was deeper, it is changed into a new one. In order to change it efficiently, it is necessary to study a period for use as the floor panel applied the repetition of local compression load for the longitudinal direction of honeycomb core (hereafter, fatigue life for brevity). The local compression fatigue tests of peripherally clamped HSPs were carried out. In this study, it is attempted to clarify the local compression fatigue property of roll core sandwich panel which was superior to the honeycomb core sandwich panel in the manufacturing cost and the mechanical property. From the obtained results, the follows were summarized; 1) There were three fracture patterns such as a tensile and a shearing types that fractured on the border of the indenter contact region and the noncontact region of specimen and a shearing around dent type that fractured on the periphery of a dent formed during the indentation. 2) The stress state at a crack initiation site governed a fatigue life. 3) Not a core shape but a cell size influenced the fatigue life.
format article
author Yukiyoshi KOBAYASHI
Yoshinao KISHIMOTO
Toshihisa OHTSUKA
Akira KARATSU
author_facet Yukiyoshi KOBAYASHI
Yoshinao KISHIMOTO
Toshihisa OHTSUKA
Akira KARATSU
author_sort Yukiyoshi KOBAYASHI
title Local compression fatigue property of roll core sandwich panel
title_short Local compression fatigue property of roll core sandwich panel
title_full Local compression fatigue property of roll core sandwich panel
title_fullStr Local compression fatigue property of roll core sandwich panel
title_full_unstemmed Local compression fatigue property of roll core sandwich panel
title_sort local compression fatigue property of roll core sandwich panel
publisher The Japan Society of Mechanical Engineers
publishDate 2014
url https://doaj.org/article/9e19024a7e24479aafcb183362026317
work_keys_str_mv AT yukiyoshikobayashi localcompressionfatiguepropertyofrollcoresandwichpanel
AT yoshinaokishimoto localcompressionfatiguepropertyofrollcoresandwichpanel
AT toshihisaohtsuka localcompressionfatiguepropertyofrollcoresandwichpanel
AT akirakaratsu localcompressionfatiguepropertyofrollcoresandwichpanel
_version_ 1718409797113479168