A new laryngeal mask supraglottic airway device with integrated balloon line: a descriptive and comparative bench study

YingHai Zhou,1 Korinne Jew2 1Research & Development, Patient Monitoring & Recovery, Medtronic Technology Center, Shanghai, People’s Republic of China; 2Medical Affairs, Minimally Invasive Therapies Group, Medtronic, Boulder, CO, USA Abstract: Laryngeal masks are invasive de...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Zhou YH, Jew K
Formato: article
Lenguaje:EN
Publicado: Dove Medical Press 2016
Materias:
Acceso en línea:https://doaj.org/article/9e2b66920c7c49dc81097535074d8809
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:9e2b66920c7c49dc81097535074d8809
record_format dspace
spelling oai:doaj.org-article:9e2b66920c7c49dc81097535074d88092021-12-02T03:38:35ZA new laryngeal mask supraglottic airway device with integrated balloon line: a descriptive and comparative bench study1179-1470https://doaj.org/article/9e2b66920c7c49dc81097535074d88092016-11-01T00:00:00Zhttps://www.dovepress.com/a-new-laryngeal-mask-supraglottic-airway-device-with-integrated-balloo-peer-reviewed-article-MDERhttps://doaj.org/toc/1179-1470YingHai Zhou,1 Korinne Jew2 1Research & Development, Patient Monitoring & Recovery, Medtronic Technology Center, Shanghai, People’s Republic of China; 2Medical Affairs, Minimally Invasive Therapies Group, Medtronic, Boulder, CO, USA Abstract: Laryngeal masks are invasive devices for airway management placed in the supraglottic position. The Shiley™ laryngeal mask (Shiley™ LM) features an integrated inflation tube and airway shaft to facilitate product insertion and reduce the chance of tube occlusion when patients bite down. This study compared the Shiley LM to two other disposable laryngeal mask devices, the Ambu® AuraStraight™ and the LMA Unique™. Overall device design, tensile strength, flexibility of various structures, and sealing performance were measured. The Shiley LM is structurally stronger and its shaft is more resistant to compression than the other devices. The Shiley LM is generally less flexible than the other devices, but this relationship varies with device size. Sealing performance of the devices was similar in a bench assay. The results of this bench study demonstrate that the new Shiley LM resembles other commercially available laryngeal mask devices, though it exhibits greater tensile strength and lower flexibility. Keywords: laryngeal mask, supraglottic airway, supralaryngeal deviceZhou YHJew KDove Medical Pressarticlelaryngeal masksupraglottic airwaysupralaryngeal deviceMedical technologyR855-855.5ENMedical Devices: Evidence and Research, Vol Volume 9, Pp 383-388 (2016)
institution DOAJ
collection DOAJ
language EN
topic laryngeal mask
supraglottic airway
supralaryngeal device
Medical technology
R855-855.5
spellingShingle laryngeal mask
supraglottic airway
supralaryngeal device
Medical technology
R855-855.5
Zhou YH
Jew K
A new laryngeal mask supraglottic airway device with integrated balloon line: a descriptive and comparative bench study
description YingHai Zhou,1 Korinne Jew2 1Research & Development, Patient Monitoring & Recovery, Medtronic Technology Center, Shanghai, People’s Republic of China; 2Medical Affairs, Minimally Invasive Therapies Group, Medtronic, Boulder, CO, USA Abstract: Laryngeal masks are invasive devices for airway management placed in the supraglottic position. The Shiley™ laryngeal mask (Shiley™ LM) features an integrated inflation tube and airway shaft to facilitate product insertion and reduce the chance of tube occlusion when patients bite down. This study compared the Shiley LM to two other disposable laryngeal mask devices, the Ambu® AuraStraight™ and the LMA Unique™. Overall device design, tensile strength, flexibility of various structures, and sealing performance were measured. The Shiley LM is structurally stronger and its shaft is more resistant to compression than the other devices. The Shiley LM is generally less flexible than the other devices, but this relationship varies with device size. Sealing performance of the devices was similar in a bench assay. The results of this bench study demonstrate that the new Shiley LM resembles other commercially available laryngeal mask devices, though it exhibits greater tensile strength and lower flexibility. Keywords: laryngeal mask, supraglottic airway, supralaryngeal device
format article
author Zhou YH
Jew K
author_facet Zhou YH
Jew K
author_sort Zhou YH
title A new laryngeal mask supraglottic airway device with integrated balloon line: a descriptive and comparative bench study
title_short A new laryngeal mask supraglottic airway device with integrated balloon line: a descriptive and comparative bench study
title_full A new laryngeal mask supraglottic airway device with integrated balloon line: a descriptive and comparative bench study
title_fullStr A new laryngeal mask supraglottic airway device with integrated balloon line: a descriptive and comparative bench study
title_full_unstemmed A new laryngeal mask supraglottic airway device with integrated balloon line: a descriptive and comparative bench study
title_sort new laryngeal mask supraglottic airway device with integrated balloon line: a descriptive and comparative bench study
publisher Dove Medical Press
publishDate 2016
url https://doaj.org/article/9e2b66920c7c49dc81097535074d8809
work_keys_str_mv AT zhouyh anewlaryngealmasksupraglotticairwaydevicewithintegratedballoonlineadescriptiveandcomparativebenchstudy
AT jewk anewlaryngealmasksupraglotticairwaydevicewithintegratedballoonlineadescriptiveandcomparativebenchstudy
AT zhouyh newlaryngealmasksupraglotticairwaydevicewithintegratedballoonlineadescriptiveandcomparativebenchstudy
AT jewk newlaryngealmasksupraglotticairwaydevicewithintegratedballoonlineadescriptiveandcomparativebenchstudy
_version_ 1718401685223636992