The relationship of pre-corneal to pre-contact lens non-invasive tear breakup time.
<h4>Purpose</h4>To examine the relationship between pre-corneal and pre-contact lens tear film stability (TFS), and to determine whether pre-corneal TFS is a reliable predictor of subsequent pre-lens TFS after a contact lens is placed on the eye.<h4>Methods</h4>667 records me...
Guardado en:
Autores principales: | , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
Public Library of Science (PLoS)
2021
|
Materias: | |
Acceso en línea: | https://doaj.org/article/9e3085adbd214dbeb627d32a11e15837 |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:9e3085adbd214dbeb627d32a11e15837 |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:9e3085adbd214dbeb627d32a11e158372021-12-02T20:09:56ZThe relationship of pre-corneal to pre-contact lens non-invasive tear breakup time.1932-620310.1371/journal.pone.0247877https://doaj.org/article/9e3085adbd214dbeb627d32a11e158372021-01-01T00:00:00Zhttps://doi.org/10.1371/journal.pone.0247877https://doaj.org/toc/1932-6203<h4>Purpose</h4>To examine the relationship between pre-corneal and pre-contact lens tear film stability (TFS), and to determine whether pre-corneal TFS is a reliable predictor of subsequent pre-lens TFS after a contact lens is placed on the eye.<h4>Methods</h4>667 records met inclusion criteria and were extracted from a soft contact lens multi-study database. Multivariable linear mixed effects models were fit to examine the association between pre-corneal and pre-lens TFS, adjusting for potential confounders and accounting for repeated measures. Receiver Operating Characteristic (ROC) analysis was employed to assess the predictive performance of pre-corneal TFS for subsequent pre-lens TFS. TFS was quantified for this analysis as the non-invasive tear breakup time (NITBUT).<h4>Results</h4>Pre-corneal NITBUT was significantly related to the pre-lens NITBUT at both 10 min (p<0.001) and 2-6 hrs (p<0.001) post-lens insertion. However, the sensitivities of pre-corneal NITBUT for predicting symptom-associated thresholds of pre-lens NITBUT ranged from 50-65%, and specificities ranged from 57-72%, suggesting poor-to-moderate diagnostic performance.<h4>Conclusions</h4>Despite the association of pre-corneal and pre-lens TFS, the inherent lability and sensitivity to environmental exposures of the tear film introduce significant variability into NITBUT measurements. Using pre-corneal NITBUT to identify likely successful contact lens candidates prior to fitting is thus not sufficiently accurate to be relied upon in the clinical setting.Andrew D GrahamMeng C LinPublic Library of Science (PLoS)articleMedicineRScienceQENPLoS ONE, Vol 16, Iss 6, p e0247877 (2021) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
Medicine R Science Q |
spellingShingle |
Medicine R Science Q Andrew D Graham Meng C Lin The relationship of pre-corneal to pre-contact lens non-invasive tear breakup time. |
description |
<h4>Purpose</h4>To examine the relationship between pre-corneal and pre-contact lens tear film stability (TFS), and to determine whether pre-corneal TFS is a reliable predictor of subsequent pre-lens TFS after a contact lens is placed on the eye.<h4>Methods</h4>667 records met inclusion criteria and were extracted from a soft contact lens multi-study database. Multivariable linear mixed effects models were fit to examine the association between pre-corneal and pre-lens TFS, adjusting for potential confounders and accounting for repeated measures. Receiver Operating Characteristic (ROC) analysis was employed to assess the predictive performance of pre-corneal TFS for subsequent pre-lens TFS. TFS was quantified for this analysis as the non-invasive tear breakup time (NITBUT).<h4>Results</h4>Pre-corneal NITBUT was significantly related to the pre-lens NITBUT at both 10 min (p<0.001) and 2-6 hrs (p<0.001) post-lens insertion. However, the sensitivities of pre-corneal NITBUT for predicting symptom-associated thresholds of pre-lens NITBUT ranged from 50-65%, and specificities ranged from 57-72%, suggesting poor-to-moderate diagnostic performance.<h4>Conclusions</h4>Despite the association of pre-corneal and pre-lens TFS, the inherent lability and sensitivity to environmental exposures of the tear film introduce significant variability into NITBUT measurements. Using pre-corneal NITBUT to identify likely successful contact lens candidates prior to fitting is thus not sufficiently accurate to be relied upon in the clinical setting. |
format |
article |
author |
Andrew D Graham Meng C Lin |
author_facet |
Andrew D Graham Meng C Lin |
author_sort |
Andrew D Graham |
title |
The relationship of pre-corneal to pre-contact lens non-invasive tear breakup time. |
title_short |
The relationship of pre-corneal to pre-contact lens non-invasive tear breakup time. |
title_full |
The relationship of pre-corneal to pre-contact lens non-invasive tear breakup time. |
title_fullStr |
The relationship of pre-corneal to pre-contact lens non-invasive tear breakup time. |
title_full_unstemmed |
The relationship of pre-corneal to pre-contact lens non-invasive tear breakup time. |
title_sort |
relationship of pre-corneal to pre-contact lens non-invasive tear breakup time. |
publisher |
Public Library of Science (PLoS) |
publishDate |
2021 |
url |
https://doaj.org/article/9e3085adbd214dbeb627d32a11e15837 |
work_keys_str_mv |
AT andrewdgraham therelationshipofprecornealtoprecontactlensnoninvasivetearbreakuptime AT mengclin therelationshipofprecornealtoprecontactlensnoninvasivetearbreakuptime AT andrewdgraham relationshipofprecornealtoprecontactlensnoninvasivetearbreakuptime AT mengclin relationshipofprecornealtoprecontactlensnoninvasivetearbreakuptime |
_version_ |
1718375080848785408 |