The Cold Bent Glass Roof of the Victoria & Albert Museum, London

The Victoria & Albert Museum in London was recently extended with its Medieval and Renaissance Galleries. Designed by MUMA Architects (London), an existing outside courtyard has been transformed by the addition of a glass roof into a light filled exhibition space.Due to the existing geometry of...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: M. Eekhout, S. Niderehe
Formato: article
Lenguaje:EN
Publicado: Challenging Glass Conference 2010
Materias:
Acceso en línea:https://doaj.org/article/9e61d534e10140d78f1ead05c5859ec2
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:9e61d534e10140d78f1ead05c5859ec2
record_format dspace
spelling oai:doaj.org-article:9e61d534e10140d78f1ead05c5859ec22021-12-04T05:12:48ZThe Cold Bent Glass Roof of the Victoria & Albert Museum, London10.7480/cgc.2.23122589-8019https://doaj.org/article/9e61d534e10140d78f1ead05c5859ec22010-05-01T00:00:00Zhttps://proceedings.challengingglass.com/index.php/cgc/article/view/48https://doaj.org/toc/2589-8019 The Victoria & Albert Museum in London was recently extended with its Medieval and Renaissance Galleries. Designed by MUMA Architects (London), an existing outside courtyard has been transformed by the addition of a glass roof into a light filled exhibition space.Due to the existing geometry of the surrounding buildings, and several boundary conditions set by the architects, the surface of the roof could not be flat. Instead, it had to be twisted into an undevelopable hypar surface. Pre-engineering by Dewhurst Macfarlane (London) indicated the possibility of achieving this surface with cold bent glass panels. The experience of Octatube with this kind of surfaces as well as the development of a theory of cold bent glass panels, transformed the possibility into a reality. A further complication of the design rested in the fact that the load bearing construction of the glass roof panels was unusually long, triple laminated glass beams. To provide a suitable fail safe concept for the glass roof, it was insufficient to consider only the separate members of the construction. Instead, to describe the fail safe behaviour of the structure, all parts had to be considered to work together during an emergency situation. M. EekhoutS. NidereheChallenging Glass Conferencearticlecold bent glasshyper surfaceglass beamsfail safeClay industries. Ceramics. GlassTP785-869ENChallenging Glass Conference Proceedings, Vol 2, Iss 1 (2010)
institution DOAJ
collection DOAJ
language EN
topic cold bent glass
hyper surface
glass beams
fail safe
Clay industries. Ceramics. Glass
TP785-869
spellingShingle cold bent glass
hyper surface
glass beams
fail safe
Clay industries. Ceramics. Glass
TP785-869
M. Eekhout
S. Niderehe
The Cold Bent Glass Roof of the Victoria & Albert Museum, London
description The Victoria & Albert Museum in London was recently extended with its Medieval and Renaissance Galleries. Designed by MUMA Architects (London), an existing outside courtyard has been transformed by the addition of a glass roof into a light filled exhibition space.Due to the existing geometry of the surrounding buildings, and several boundary conditions set by the architects, the surface of the roof could not be flat. Instead, it had to be twisted into an undevelopable hypar surface. Pre-engineering by Dewhurst Macfarlane (London) indicated the possibility of achieving this surface with cold bent glass panels. The experience of Octatube with this kind of surfaces as well as the development of a theory of cold bent glass panels, transformed the possibility into a reality. A further complication of the design rested in the fact that the load bearing construction of the glass roof panels was unusually long, triple laminated glass beams. To provide a suitable fail safe concept for the glass roof, it was insufficient to consider only the separate members of the construction. Instead, to describe the fail safe behaviour of the structure, all parts had to be considered to work together during an emergency situation.
format article
author M. Eekhout
S. Niderehe
author_facet M. Eekhout
S. Niderehe
author_sort M. Eekhout
title The Cold Bent Glass Roof of the Victoria & Albert Museum, London
title_short The Cold Bent Glass Roof of the Victoria & Albert Museum, London
title_full The Cold Bent Glass Roof of the Victoria & Albert Museum, London
title_fullStr The Cold Bent Glass Roof of the Victoria & Albert Museum, London
title_full_unstemmed The Cold Bent Glass Roof of the Victoria & Albert Museum, London
title_sort cold bent glass roof of the victoria & albert museum, london
publisher Challenging Glass Conference
publishDate 2010
url https://doaj.org/article/9e61d534e10140d78f1ead05c5859ec2
work_keys_str_mv AT meekhout thecoldbentglassroofofthevictoriaalbertmuseumlondon
AT sniderehe thecoldbentglassroofofthevictoriaalbertmuseumlondon
AT meekhout coldbentglassroofofthevictoriaalbertmuseumlondon
AT sniderehe coldbentglassroofofthevictoriaalbertmuseumlondon
_version_ 1718372870472597504