Construction of a simple and selective electrochemical sensor based on Nafion/TiO2 for the voltammetric determination of olopatadine

A selective and facile voltammetric method based on titanium dioxide nanoparticles and Nafion (Nafion/TiO2 NPs) on the screen-printed electrode (SPE) was proposed for olopatadine determination. Followed by the synthesis of TiO2 nanoparticles, various methods, including high-resolution transmission...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Mohammad Mehmandoust, Amirhossein Mehmandoust, Nevin Erk
Formato: article
Lenguaje:EN
Publicado: International Association of Physical Chemists (IAPC) 2021
Materias:
Acceso en línea:https://doaj.org/article/9eb32d80f8164960af615841e713f880
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:9eb32d80f8164960af615841e713f880
record_format dspace
spelling oai:doaj.org-article:9eb32d80f8164960af615841e713f8802021-11-20T10:07:58ZConstruction of a simple and selective electrochemical sensor based on Nafion/TiO2 for the voltammetric determination of olopatadine10.5599/jese.11171847-9286https://doaj.org/article/9eb32d80f8164960af615841e713f8802021-11-01T00:00:00Zhttps://pub.iapchem.org/ojs/index.php/JESE/article/view/1117https://doaj.org/toc/1847-9286 A selective and facile voltammetric method based on titanium dioxide nanoparticles and Nafion (Nafion/TiO2 NPs) on the screen-printed electrode (SPE) was proposed for olopatadine determination. Followed by the synthesis of TiO2 nanoparticles, various methods, including high-resolution transmission electron microscopy (HR-TEM), ultraviolet-visible spectroscopy (UV-Vis), energy-dispersive X-ray (EDX) Raman spectrum, and electrochemical impedance spectroscopy (EIS) were utilized to characterize the nanomaterials. Nafion/TiO2 on the screen-printed electrode (NFN/TiO2/SPE) was used to determine olopatadine in concentration ranges of 0.01 to 0.07 and 0.07 to 14.6 µM with a limit of quantification as low as 7.0 nM, via differential pulse voltammetry technique. The NFN/TiO2/SPE offered a high-performance ability to determine olopatadine in the eye drop sample with satisfactory recovery data of 98.2–99.0 %. Also, the developed electrode showed good reproducibility, repeatability, and high selectivity features. The obtained results indicate that NFN/TiO2/SPE could be utilized as an appropriate candidate for electrochemical olopatadine sensing. Mohammad MehmandoustAmirhossein MehmandoustNevin ErkInternational Association of Physical Chemists (IAPC)articleMonitoringscreen-printed electrodedifferential pulse voltammetryChemistryQD1-999ENJournal of Electrochemical Science and Engineering, Vol 11, Iss 3 (2021)
institution DOAJ
collection DOAJ
language EN
topic Monitoring
screen-printed electrode
differential pulse voltammetry
Chemistry
QD1-999
spellingShingle Monitoring
screen-printed electrode
differential pulse voltammetry
Chemistry
QD1-999
Mohammad Mehmandoust
Amirhossein Mehmandoust
Nevin Erk
Construction of a simple and selective electrochemical sensor based on Nafion/TiO2 for the voltammetric determination of olopatadine
description A selective and facile voltammetric method based on titanium dioxide nanoparticles and Nafion (Nafion/TiO2 NPs) on the screen-printed electrode (SPE) was proposed for olopatadine determination. Followed by the synthesis of TiO2 nanoparticles, various methods, including high-resolution transmission electron microscopy (HR-TEM), ultraviolet-visible spectroscopy (UV-Vis), energy-dispersive X-ray (EDX) Raman spectrum, and electrochemical impedance spectroscopy (EIS) were utilized to characterize the nanomaterials. Nafion/TiO2 on the screen-printed electrode (NFN/TiO2/SPE) was used to determine olopatadine in concentration ranges of 0.01 to 0.07 and 0.07 to 14.6 µM with a limit of quantification as low as 7.0 nM, via differential pulse voltammetry technique. The NFN/TiO2/SPE offered a high-performance ability to determine olopatadine in the eye drop sample with satisfactory recovery data of 98.2–99.0 %. Also, the developed electrode showed good reproducibility, repeatability, and high selectivity features. The obtained results indicate that NFN/TiO2/SPE could be utilized as an appropriate candidate for electrochemical olopatadine sensing.
format article
author Mohammad Mehmandoust
Amirhossein Mehmandoust
Nevin Erk
author_facet Mohammad Mehmandoust
Amirhossein Mehmandoust
Nevin Erk
author_sort Mohammad Mehmandoust
title Construction of a simple and selective electrochemical sensor based on Nafion/TiO2 for the voltammetric determination of olopatadine
title_short Construction of a simple and selective electrochemical sensor based on Nafion/TiO2 for the voltammetric determination of olopatadine
title_full Construction of a simple and selective electrochemical sensor based on Nafion/TiO2 for the voltammetric determination of olopatadine
title_fullStr Construction of a simple and selective electrochemical sensor based on Nafion/TiO2 for the voltammetric determination of olopatadine
title_full_unstemmed Construction of a simple and selective electrochemical sensor based on Nafion/TiO2 for the voltammetric determination of olopatadine
title_sort construction of a simple and selective electrochemical sensor based on nafion/tio2 for the voltammetric determination of olopatadine
publisher International Association of Physical Chemists (IAPC)
publishDate 2021
url https://doaj.org/article/9eb32d80f8164960af615841e713f880
work_keys_str_mv AT mohammadmehmandoust constructionofasimpleandselectiveelectrochemicalsensorbasedonnafiontio2forthevoltammetricdeterminationofolopatadine
AT amirhosseinmehmandoust constructionofasimpleandselectiveelectrochemicalsensorbasedonnafiontio2forthevoltammetricdeterminationofolopatadine
AT nevinerk constructionofasimpleandselectiveelectrochemicalsensorbasedonnafiontio2forthevoltammetricdeterminationofolopatadine
_version_ 1718419441054646272