Construction of a simple and selective electrochemical sensor based on Nafion/TiO2 for the voltammetric determination of olopatadine
A selective and facile voltammetric method based on titanium dioxide nanoparticles and Nafion (Nafion/TiO2 NPs) on the screen-printed electrode (SPE) was proposed for olopatadine determination. Followed by the synthesis of TiO2 nanoparticles, various methods, including high-resolution transmission...
Guardado en:
Autores principales: | , , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
International Association of Physical Chemists (IAPC)
2021
|
Materias: | |
Acceso en línea: | https://doaj.org/article/9eb32d80f8164960af615841e713f880 |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:9eb32d80f8164960af615841e713f880 |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:9eb32d80f8164960af615841e713f8802021-11-20T10:07:58ZConstruction of a simple and selective electrochemical sensor based on Nafion/TiO2 for the voltammetric determination of olopatadine10.5599/jese.11171847-9286https://doaj.org/article/9eb32d80f8164960af615841e713f8802021-11-01T00:00:00Zhttps://pub.iapchem.org/ojs/index.php/JESE/article/view/1117https://doaj.org/toc/1847-9286 A selective and facile voltammetric method based on titanium dioxide nanoparticles and Nafion (Nafion/TiO2 NPs) on the screen-printed electrode (SPE) was proposed for olopatadine determination. Followed by the synthesis of TiO2 nanoparticles, various methods, including high-resolution transmission electron microscopy (HR-TEM), ultraviolet-visible spectroscopy (UV-Vis), energy-dispersive X-ray (EDX) Raman spectrum, and electrochemical impedance spectroscopy (EIS) were utilized to characterize the nanomaterials. Nafion/TiO2 on the screen-printed electrode (NFN/TiO2/SPE) was used to determine olopatadine in concentration ranges of 0.01 to 0.07 and 0.07 to 14.6 µM with a limit of quantification as low as 7.0 nM, via differential pulse voltammetry technique. The NFN/TiO2/SPE offered a high-performance ability to determine olopatadine in the eye drop sample with satisfactory recovery data of 98.2–99.0 %. Also, the developed electrode showed good reproducibility, repeatability, and high selectivity features. The obtained results indicate that NFN/TiO2/SPE could be utilized as an appropriate candidate for electrochemical olopatadine sensing. Mohammad MehmandoustAmirhossein MehmandoustNevin ErkInternational Association of Physical Chemists (IAPC)articleMonitoringscreen-printed electrodedifferential pulse voltammetryChemistryQD1-999ENJournal of Electrochemical Science and Engineering, Vol 11, Iss 3 (2021) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
Monitoring screen-printed electrode differential pulse voltammetry Chemistry QD1-999 |
spellingShingle |
Monitoring screen-printed electrode differential pulse voltammetry Chemistry QD1-999 Mohammad Mehmandoust Amirhossein Mehmandoust Nevin Erk Construction of a simple and selective electrochemical sensor based on Nafion/TiO2 for the voltammetric determination of olopatadine |
description |
A selective and facile voltammetric method based on titanium dioxide nanoparticles and Nafion (Nafion/TiO2 NPs) on the screen-printed electrode (SPE) was proposed for olopatadine determination. Followed by the synthesis of TiO2 nanoparticles, various methods, including high-resolution transmission electron microscopy (HR-TEM), ultraviolet-visible spectroscopy (UV-Vis), energy-dispersive X-ray (EDX) Raman spectrum, and electrochemical impedance spectroscopy (EIS) were utilized to characterize the nanomaterials. Nafion/TiO2 on the screen-printed electrode (NFN/TiO2/SPE) was used to determine olopatadine in concentration ranges of 0.01 to 0.07 and 0.07 to 14.6 µM with a limit of quantification as low as 7.0 nM, via differential pulse voltammetry technique. The NFN/TiO2/SPE offered a high-performance ability to determine olopatadine in the eye drop sample with satisfactory recovery data of 98.2–99.0 %. Also, the developed electrode showed good reproducibility, repeatability, and high selectivity features. The obtained results indicate that NFN/TiO2/SPE could be utilized as an appropriate candidate for electrochemical olopatadine sensing.
|
format |
article |
author |
Mohammad Mehmandoust Amirhossein Mehmandoust Nevin Erk |
author_facet |
Mohammad Mehmandoust Amirhossein Mehmandoust Nevin Erk |
author_sort |
Mohammad Mehmandoust |
title |
Construction of a simple and selective electrochemical sensor based on Nafion/TiO2 for the voltammetric determination of olopatadine |
title_short |
Construction of a simple and selective electrochemical sensor based on Nafion/TiO2 for the voltammetric determination of olopatadine |
title_full |
Construction of a simple and selective electrochemical sensor based on Nafion/TiO2 for the voltammetric determination of olopatadine |
title_fullStr |
Construction of a simple and selective electrochemical sensor based on Nafion/TiO2 for the voltammetric determination of olopatadine |
title_full_unstemmed |
Construction of a simple and selective electrochemical sensor based on Nafion/TiO2 for the voltammetric determination of olopatadine |
title_sort |
construction of a simple and selective electrochemical sensor based on nafion/tio2 for the voltammetric determination of olopatadine |
publisher |
International Association of Physical Chemists (IAPC) |
publishDate |
2021 |
url |
https://doaj.org/article/9eb32d80f8164960af615841e713f880 |
work_keys_str_mv |
AT mohammadmehmandoust constructionofasimpleandselectiveelectrochemicalsensorbasedonnafiontio2forthevoltammetricdeterminationofolopatadine AT amirhosseinmehmandoust constructionofasimpleandselectiveelectrochemicalsensorbasedonnafiontio2forthevoltammetricdeterminationofolopatadine AT nevinerk constructionofasimpleandselectiveelectrochemicalsensorbasedonnafiontio2forthevoltammetricdeterminationofolopatadine |
_version_ |
1718419441054646272 |