Improving of Maintenance of Humidifying System in Conventional Wood Kiln Dryers

During wood drying, the formation of limescale deposits on conventional drying kiln components frequently causes difficulties, especially on nozzles for dispersion of water mist, as a result of the use of “hard water” and technologically unprepared water. Frequently inadequate cleaners for the remov...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Miljenko Klarić, Stjepan Pervan
Formato: article
Lenguaje:EN
Publicado: University of Zagreb, Faculty of Forestry and Wood Technology 2012
Materias:
Acceso en línea:https://doaj.org/article/9ebf0632e99743abb62426f6d1a74deb
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:9ebf0632e99743abb62426f6d1a74deb
record_format dspace
spelling oai:doaj.org-article:9ebf0632e99743abb62426f6d1a74deb2021-12-02T01:09:02ZImproving of Maintenance of Humidifying System in Conventional Wood Kiln Dryers0012-67721847-1153https://doaj.org/article/9ebf0632e99743abb62426f6d1a74deb2012-06-01T00:00:00Zhttp://hrcak.srce.hr/index.php?show=clanak&id_clanak_jezik=124234https://doaj.org/toc/0012-6772https://doaj.org/toc/1847-1153During wood drying, the formation of limescale deposits on conventional drying kiln components frequently causes difficulties, especially on nozzles for dispersion of water mist, as a result of the use of “hard water” and technologically unprepared water. Frequently inadequate cleaners for the removal of limescale are used, which have harmful effects on the equipment and people. In order to reduce costs incurred due to the use of inadequate cleaners for the removal of limescale and to eliminate potentially harmful effects on the health of employees, the use of citric acid has been researched in procedures of removal of limescale from the moisturizer nozzles of the conventional drying kilns. Used and unused metal moisturizer nozzles of the conventional drying kilns have been treated with different concentrations of water solution of citric acid at ambient temperature and in boiled state for 5 and 10 minutes. It has been determined that the water solution of citric acid at ambient temperature does not give positive results, while the treatment of nozzles in the boiled water solution of citric acid gives very good results already at minimum concentration of citric acid, both for the cleaning of limescale and for the cleaning of corrosion, resulting in fully renewed functionality of nozzles. No adverse effects of citric acid on the body of metal nozzles have been recorded.Miljenko KlarićStjepan PervanUniversity of Zagreb, Faculty of Forestry and Wood Technologyarticleconventional wood drying kilnwood dryingmoisturizer nozzleslimescalecitric acid monohydrateForestrySD1-669.5ENDrvna Industrija, Vol 63, Iss 2, Pp 87-94 (2012)
institution DOAJ
collection DOAJ
language EN
topic conventional wood drying kiln
wood drying
moisturizer nozzles
limescale
citric acid monohydrate
Forestry
SD1-669.5
spellingShingle conventional wood drying kiln
wood drying
moisturizer nozzles
limescale
citric acid monohydrate
Forestry
SD1-669.5
Miljenko Klarić
Stjepan Pervan
Improving of Maintenance of Humidifying System in Conventional Wood Kiln Dryers
description During wood drying, the formation of limescale deposits on conventional drying kiln components frequently causes difficulties, especially on nozzles for dispersion of water mist, as a result of the use of “hard water” and technologically unprepared water. Frequently inadequate cleaners for the removal of limescale are used, which have harmful effects on the equipment and people. In order to reduce costs incurred due to the use of inadequate cleaners for the removal of limescale and to eliminate potentially harmful effects on the health of employees, the use of citric acid has been researched in procedures of removal of limescale from the moisturizer nozzles of the conventional drying kilns. Used and unused metal moisturizer nozzles of the conventional drying kilns have been treated with different concentrations of water solution of citric acid at ambient temperature and in boiled state for 5 and 10 minutes. It has been determined that the water solution of citric acid at ambient temperature does not give positive results, while the treatment of nozzles in the boiled water solution of citric acid gives very good results already at minimum concentration of citric acid, both for the cleaning of limescale and for the cleaning of corrosion, resulting in fully renewed functionality of nozzles. No adverse effects of citric acid on the body of metal nozzles have been recorded.
format article
author Miljenko Klarić
Stjepan Pervan
author_facet Miljenko Klarić
Stjepan Pervan
author_sort Miljenko Klarić
title Improving of Maintenance of Humidifying System in Conventional Wood Kiln Dryers
title_short Improving of Maintenance of Humidifying System in Conventional Wood Kiln Dryers
title_full Improving of Maintenance of Humidifying System in Conventional Wood Kiln Dryers
title_fullStr Improving of Maintenance of Humidifying System in Conventional Wood Kiln Dryers
title_full_unstemmed Improving of Maintenance of Humidifying System in Conventional Wood Kiln Dryers
title_sort improving of maintenance of humidifying system in conventional wood kiln dryers
publisher University of Zagreb, Faculty of Forestry and Wood Technology
publishDate 2012
url https://doaj.org/article/9ebf0632e99743abb62426f6d1a74deb
work_keys_str_mv AT miljenkoklaric improvingofmaintenanceofhumidifyingsysteminconventionalwoodkilndryers
AT stjepanpervan improvingofmaintenanceofhumidifyingsysteminconventionalwoodkilndryers
_version_ 1718403275001167872