Using shear wave elastography to assess uterine tonicity after vaginal delivery

Abstract This study aims to evaluate the feasibility and clinical interest of shear wave elastography, by quantitatively estimating the baseline stiffness of the myometrium before and after placental expulsion. We conducted a prospective cohort study of women at term, without known risk factors for...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Joanna Sichitiu, Jean-Yves Meuwly, David Baud, David Desseauve
Formato: article
Lenguaje:EN
Publicado: Nature Portfolio 2021
Materias:
R
Q
Acceso en línea:https://doaj.org/article/9fb6945fa7604d1a86f4006c7de36785
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:9fb6945fa7604d1a86f4006c7de36785
record_format dspace
spelling oai:doaj.org-article:9fb6945fa7604d1a86f4006c7de367852021-12-02T15:45:31ZUsing shear wave elastography to assess uterine tonicity after vaginal delivery10.1038/s41598-021-89756-62045-2322https://doaj.org/article/9fb6945fa7604d1a86f4006c7de367852021-05-01T00:00:00Zhttps://doi.org/10.1038/s41598-021-89756-6https://doaj.org/toc/2045-2322Abstract This study aims to evaluate the feasibility and clinical interest of shear wave elastography, by quantitatively estimating the baseline stiffness of the myometrium before and after placental expulsion. We conducted a prospective cohort study of women at term, without known risk factors for postpartum hemorrhage, who gave birth via spontaneous labor in our tertiary center. Myometrium tonicity was evaluated based on measurements of shear wave speed (SWS) in the anterior uterine corpus. All data points were collected by a single operator. Measurements were carried out at three different time points: after fetal delivery (T1), after placental delivery (T2) and 30 min after placental delivery (T3). Our primary objective was to assess the feasibility of this new imaging technique. Ten valid SWS measurements obtained at each of the three different time points were considered as a positive primary outcome. Our secondary objectives were to evaluate the difference in median myometrial shear wave velocity between each time point, as well as to determine the correlation between myometrial shear wave velocity and patients’ characteristics. 38 women were recruited during the study period, of whom 34 met the study criteria. 1017 SWS measurements were obtained. The median time to perform measurements was 16 s for one value, and 2 min 56 s for ten. For 11 women (32%) it was not possible to achieve ten SWS at T1 as placental expulsion immediately followed the birth of the newborn. One patient experienced placental retention and only measurements at T1 were performed. For all other patients, we were successfully able to obtain all measures as intended. There was no difference in the mean shear wave speed between the three time points. After adjustments for confounders, we observed a significant correlation for total blood loss (correlation coefficient = − 0.26, p < 0.001, units of oxytocin (correlation coefficient = − 0.34, p = 0.03), and newborn weight (correlation coefficient = − 0.08, p = 0.001). It is feasible to assess uterine tonicity by shear wave imaging, after placental expulsion. We did not observe a variance in uterine tonicity between the three time points. Women who had higher blood loss, received more units of oxytocin and/or those with newborns of a higher weight exhibited lower shear wave speed measures.Joanna SichitiuJean-Yves MeuwlyDavid BaudDavid DesseauveNature PortfolioarticleMedicineRScienceQENScientific Reports, Vol 11, Iss 1, Pp 1-8 (2021)
institution DOAJ
collection DOAJ
language EN
topic Medicine
R
Science
Q
spellingShingle Medicine
R
Science
Q
Joanna Sichitiu
Jean-Yves Meuwly
David Baud
David Desseauve
Using shear wave elastography to assess uterine tonicity after vaginal delivery
description Abstract This study aims to evaluate the feasibility and clinical interest of shear wave elastography, by quantitatively estimating the baseline stiffness of the myometrium before and after placental expulsion. We conducted a prospective cohort study of women at term, without known risk factors for postpartum hemorrhage, who gave birth via spontaneous labor in our tertiary center. Myometrium tonicity was evaluated based on measurements of shear wave speed (SWS) in the anterior uterine corpus. All data points were collected by a single operator. Measurements were carried out at three different time points: after fetal delivery (T1), after placental delivery (T2) and 30 min after placental delivery (T3). Our primary objective was to assess the feasibility of this new imaging technique. Ten valid SWS measurements obtained at each of the three different time points were considered as a positive primary outcome. Our secondary objectives were to evaluate the difference in median myometrial shear wave velocity between each time point, as well as to determine the correlation between myometrial shear wave velocity and patients’ characteristics. 38 women were recruited during the study period, of whom 34 met the study criteria. 1017 SWS measurements were obtained. The median time to perform measurements was 16 s for one value, and 2 min 56 s for ten. For 11 women (32%) it was not possible to achieve ten SWS at T1 as placental expulsion immediately followed the birth of the newborn. One patient experienced placental retention and only measurements at T1 were performed. For all other patients, we were successfully able to obtain all measures as intended. There was no difference in the mean shear wave speed between the three time points. After adjustments for confounders, we observed a significant correlation for total blood loss (correlation coefficient = − 0.26, p < 0.001, units of oxytocin (correlation coefficient = − 0.34, p = 0.03), and newborn weight (correlation coefficient = − 0.08, p = 0.001). It is feasible to assess uterine tonicity by shear wave imaging, after placental expulsion. We did not observe a variance in uterine tonicity between the three time points. Women who had higher blood loss, received more units of oxytocin and/or those with newborns of a higher weight exhibited lower shear wave speed measures.
format article
author Joanna Sichitiu
Jean-Yves Meuwly
David Baud
David Desseauve
author_facet Joanna Sichitiu
Jean-Yves Meuwly
David Baud
David Desseauve
author_sort Joanna Sichitiu
title Using shear wave elastography to assess uterine tonicity after vaginal delivery
title_short Using shear wave elastography to assess uterine tonicity after vaginal delivery
title_full Using shear wave elastography to assess uterine tonicity after vaginal delivery
title_fullStr Using shear wave elastography to assess uterine tonicity after vaginal delivery
title_full_unstemmed Using shear wave elastography to assess uterine tonicity after vaginal delivery
title_sort using shear wave elastography to assess uterine tonicity after vaginal delivery
publisher Nature Portfolio
publishDate 2021
url https://doaj.org/article/9fb6945fa7604d1a86f4006c7de36785
work_keys_str_mv AT joannasichitiu usingshearwaveelastographytoassessuterinetonicityaftervaginaldelivery
AT jeanyvesmeuwly usingshearwaveelastographytoassessuterinetonicityaftervaginaldelivery
AT davidbaud usingshearwaveelastographytoassessuterinetonicityaftervaginaldelivery
AT daviddesseauve usingshearwaveelastographytoassessuterinetonicityaftervaginaldelivery
_version_ 1718385767066107904