Influence of Draft Tube Diameter on Operation Behaviorof Air Lift Loop Reactors

The ratio of draft tube to reactor diameters is of decisive importance for the operation behavior of air lift loop reactors. The influence of draft tube geometry was investigated with respect to oxygen mass transfer and mixing time. The diameter ratio was varied between 0.33 and 0.80. The measuremen...

Description complète

Enregistré dans:
Détails bibliographiques
Auteurs principaux: Laith S. S. Al-Kuffe, Ali Abdul-Rahman Al-Azzi
Format: article
Langue:EN
Publié: Al-Khwarizmi College of Engineering – University of Baghdad 2010
Sujets:
Accès en ligne:https://doaj.org/article/a1635e0c624e46c6a0ed89aa8906ea44
Tags: Ajouter un tag
Pas de tags, Soyez le premier à ajouter un tag!
Description
Résumé:The ratio of draft tube to reactor diameters is of decisive importance for the operation behavior of air lift loop reactors. The influence of draft tube geometry was investigated with respect to oxygen mass transfer and mixing time. The diameter ratio was varied between 0.33 and 0.80. The measurements were performed in two loop reactors with liquid capacities of 11.775 and 26.49 liters using aqueous with solutions of different coalescence behavior. The results show that there is no single diameter ratio which would produce most favorable conditions for the two process parameters. With respect to the more important requirements of aerobic cultures, i.e high oxygen mass transfer and efficient mixing, a diameter ratio between 0.5 and 0.6 is recommended. If high liquid velocities in the draft tube are required a ratio of 0.6 should be used.