Influence of Draft Tube Diameter on Operation Behaviorof Air Lift Loop Reactors
The ratio of draft tube to reactor diameters is of decisive importance for the operation behavior of air lift loop reactors. The influence of draft tube geometry was investigated with respect to oxygen mass transfer and mixing time. The diameter ratio was varied between 0.33 and 0.80. The measuremen...
Enregistré dans:
Auteurs principaux: | , |
---|---|
Format: | article |
Langue: | EN |
Publié: |
Al-Khwarizmi College of Engineering – University of Baghdad
2010
|
Sujets: | |
Accès en ligne: | https://doaj.org/article/a1635e0c624e46c6a0ed89aa8906ea44 |
Tags: |
Ajouter un tag
Pas de tags, Soyez le premier à ajouter un tag!
|
id |
oai:doaj.org-article:a1635e0c624e46c6a0ed89aa8906ea44 |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:a1635e0c624e46c6a0ed89aa8906ea442021-12-02T05:01:20ZInfluence of Draft Tube Diameter on Operation Behaviorof Air Lift Loop Reactors1818-1171https://doaj.org/article/a1635e0c624e46c6a0ed89aa8906ea442010-01-01T00:00:00Zhttp://www.iasj.net/iasj?func=fulltext&aId=2299https://doaj.org/toc/1818-1171The ratio of draft tube to reactor diameters is of decisive importance for the operation behavior of air lift loop reactors. The influence of draft tube geometry was investigated with respect to oxygen mass transfer and mixing time. The diameter ratio was varied between 0.33 and 0.80. The measurements were performed in two loop reactors with liquid capacities of 11.775 and 26.49 liters using aqueous with solutions of different coalescence behavior. The results show that there is no single diameter ratio which would produce most favorable conditions for the two process parameters. With respect to the more important requirements of aerobic cultures, i.e high oxygen mass transfer and efficient mixing, a diameter ratio between 0.5 and 0.6 is recommended. If high liquid velocities in the draft tube are required a ratio of 0.6 should be used. Laith S. S. Al-KuffeAli Abdul-Rahman Al-AzziAl-Khwarizmi College of Engineering – University of BaghdadarticleDraft tubeloop reactorsmass transfermixing time.Chemical engineeringTP155-156Engineering (General). Civil engineering (General)TA1-2040ENAl-Khawarizmi Engineering Journal, Vol 6, Iss 2, Pp 21-32 (2010) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
Draft tube loop reactors mass transfer mixing time. Chemical engineering TP155-156 Engineering (General). Civil engineering (General) TA1-2040 |
spellingShingle |
Draft tube loop reactors mass transfer mixing time. Chemical engineering TP155-156 Engineering (General). Civil engineering (General) TA1-2040 Laith S. S. Al-Kuffe Ali Abdul-Rahman Al-Azzi Influence of Draft Tube Diameter on Operation Behaviorof Air Lift Loop Reactors |
description |
The ratio of draft tube to reactor diameters is of decisive importance for the operation behavior of air lift loop reactors. The influence of draft tube geometry was investigated with respect to oxygen mass transfer and mixing time. The diameter ratio was varied between 0.33 and 0.80. The measurements were performed in two loop reactors with liquid capacities of 11.775 and 26.49 liters using aqueous with solutions of different coalescence behavior. The results show that there is no single diameter ratio which would produce most favorable conditions for the two process parameters. With respect to the more important requirements of aerobic cultures, i.e high oxygen mass transfer and efficient mixing, a diameter ratio between 0.5 and 0.6 is recommended. If high liquid velocities in the draft tube are required a ratio of 0.6 should be used. |
format |
article |
author |
Laith S. S. Al-Kuffe Ali Abdul-Rahman Al-Azzi |
author_facet |
Laith S. S. Al-Kuffe Ali Abdul-Rahman Al-Azzi |
author_sort |
Laith S. S. Al-Kuffe |
title |
Influence of Draft Tube Diameter on Operation Behaviorof Air Lift Loop Reactors |
title_short |
Influence of Draft Tube Diameter on Operation Behaviorof Air Lift Loop Reactors |
title_full |
Influence of Draft Tube Diameter on Operation Behaviorof Air Lift Loop Reactors |
title_fullStr |
Influence of Draft Tube Diameter on Operation Behaviorof Air Lift Loop Reactors |
title_full_unstemmed |
Influence of Draft Tube Diameter on Operation Behaviorof Air Lift Loop Reactors |
title_sort |
influence of draft tube diameter on operation behaviorof air lift loop reactors |
publisher |
Al-Khwarizmi College of Engineering – University of Baghdad |
publishDate |
2010 |
url |
https://doaj.org/article/a1635e0c624e46c6a0ed89aa8906ea44 |
work_keys_str_mv |
AT laithssalkuffe influenceofdrafttubediameteronoperationbehaviorofairliftloopreactors AT aliabdulrahmanalazzi influenceofdrafttubediameteronoperationbehaviorofairliftloopreactors |
_version_ |
1718400845520830464 |