Alternative method’s results for the non targeted determination of xenobiotics in food by means of high resolution and accuracy mass spectrometry
Abstract The application of a high resolution and accurate mass spectrometry (HRAMS) approach to detect xenobiotics in different food matrices by means of non targeted determination by UHPLC-Orbitrap followed by data processing analysis was described. Three case studies were reported to demonstrate...
Guardado en:
Autores principales: | , , , , , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
BMC
2021
|
Materias: | |
Acceso en línea: | https://doaj.org/article/a1d2950b2b7f44a5a6f7936c979fb2e8 |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:a1d2950b2b7f44a5a6f7936c979fb2e8 |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:a1d2950b2b7f44a5a6f7936c979fb2e82021-11-14T12:06:25ZAlternative method’s results for the non targeted determination of xenobiotics in food by means of high resolution and accuracy mass spectrometry10.1186/s40550-021-00086-x2196-2804https://doaj.org/article/a1d2950b2b7f44a5a6f7936c979fb2e82021-11-01T00:00:00Zhttps://doi.org/10.1186/s40550-021-00086-xhttps://doaj.org/toc/2196-2804Abstract The application of a high resolution and accurate mass spectrometry (HRAMS) approach to detect xenobiotics in different food matrices by means of non targeted determination by UHPLC-Orbitrap followed by data processing analysis was described. Three case studies were reported to demonstrate the possibility to identify unexpected substances in different food commodities overcomes targeted method. This innovative approach could lay the foundation for its applicability to routine analysis in the near future giving the possibility to open new horizons to the research of a wide range of xenobiotics.Rossana ScarponeRachele RocchiFederico BacàRoberta RosatoFrancesco ChiumientoGiacomo MiglioratiBMCarticleHigh resolution accurate mass spectrometryNon-target screeningFoodXenobioticsDifferential analysisFood processing and manufactureTP368-456ENInternational Journal of Food Contamination, Vol 8, Iss 1, Pp 1-8 (2021) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
High resolution accurate mass spectrometry Non-target screening Food Xenobiotics Differential analysis Food processing and manufacture TP368-456 |
spellingShingle |
High resolution accurate mass spectrometry Non-target screening Food Xenobiotics Differential analysis Food processing and manufacture TP368-456 Rossana Scarpone Rachele Rocchi Federico Bacà Roberta Rosato Francesco Chiumiento Giacomo Migliorati Alternative method’s results for the non targeted determination of xenobiotics in food by means of high resolution and accuracy mass spectrometry |
description |
Abstract The application of a high resolution and accurate mass spectrometry (HRAMS) approach to detect xenobiotics in different food matrices by means of non targeted determination by UHPLC-Orbitrap followed by data processing analysis was described. Three case studies were reported to demonstrate the possibility to identify unexpected substances in different food commodities overcomes targeted method. This innovative approach could lay the foundation for its applicability to routine analysis in the near future giving the possibility to open new horizons to the research of a wide range of xenobiotics. |
format |
article |
author |
Rossana Scarpone Rachele Rocchi Federico Bacà Roberta Rosato Francesco Chiumiento Giacomo Migliorati |
author_facet |
Rossana Scarpone Rachele Rocchi Federico Bacà Roberta Rosato Francesco Chiumiento Giacomo Migliorati |
author_sort |
Rossana Scarpone |
title |
Alternative method’s results for the non targeted determination of xenobiotics in food by means of high resolution and accuracy mass spectrometry |
title_short |
Alternative method’s results for the non targeted determination of xenobiotics in food by means of high resolution and accuracy mass spectrometry |
title_full |
Alternative method’s results for the non targeted determination of xenobiotics in food by means of high resolution and accuracy mass spectrometry |
title_fullStr |
Alternative method’s results for the non targeted determination of xenobiotics in food by means of high resolution and accuracy mass spectrometry |
title_full_unstemmed |
Alternative method’s results for the non targeted determination of xenobiotics in food by means of high resolution and accuracy mass spectrometry |
title_sort |
alternative method’s results for the non targeted determination of xenobiotics in food by means of high resolution and accuracy mass spectrometry |
publisher |
BMC |
publishDate |
2021 |
url |
https://doaj.org/article/a1d2950b2b7f44a5a6f7936c979fb2e8 |
work_keys_str_mv |
AT rossanascarpone alternativemethodsresultsforthenontargeteddeterminationofxenobioticsinfoodbymeansofhighresolutionandaccuracymassspectrometry AT rachelerocchi alternativemethodsresultsforthenontargeteddeterminationofxenobioticsinfoodbymeansofhighresolutionandaccuracymassspectrometry AT federicobaca alternativemethodsresultsforthenontargeteddeterminationofxenobioticsinfoodbymeansofhighresolutionandaccuracymassspectrometry AT robertarosato alternativemethodsresultsforthenontargeteddeterminationofxenobioticsinfoodbymeansofhighresolutionandaccuracymassspectrometry AT francescochiumiento alternativemethodsresultsforthenontargeteddeterminationofxenobioticsinfoodbymeansofhighresolutionandaccuracymassspectrometry AT giacomomigliorati alternativemethodsresultsforthenontargeteddeterminationofxenobioticsinfoodbymeansofhighresolutionandaccuracymassspectrometry |
_version_ |
1718429480199913472 |