MONITORING OF ELECTRICAL ENERGY QUALITY ON THE TRACTION SUBSTATION INPUT
For the implementation of measures to maintain the quality of the energy industrial enterprises have to spend a significant material and monetary assets. In this regard, significant is the feasibility study of the allocation of such funds and, primarily, the determination of the economic damage aris...
Guardado en:
Autores principales: | , , , , |
---|---|
Formato: | article |
Lenguaje: | EN RU UK |
Publicado: |
National Technical University "Kharkiv Polytechnic Institute"
2015
|
Materias: | |
Acceso en línea: | https://doaj.org/article/a26bb7271c764656b2bbdc54b8a03a45 |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:a26bb7271c764656b2bbdc54b8a03a45 |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:a26bb7271c764656b2bbdc54b8a03a452021-12-02T16:20:09ZMONITORING OF ELECTRICAL ENERGY QUALITY ON THE TRACTION SUBSTATION INPUT2074-272X2309-3404https://doaj.org/article/a26bb7271c764656b2bbdc54b8a03a452015-12-01T00:00:00Zhttp://eie.khpi.edu.ua/article/view/54568/50958https://doaj.org/toc/2074-272Xhttps://doaj.org/toc/2309-3404For the implementation of measures to maintain the quality of the energy industrial enterprises have to spend a significant material and monetary assets. In this regard, significant is the feasibility study of the allocation of such funds and, primarily, the determination of the economic damage arising from low quality of electricity. The reliability of the electricity metering system, relay protection and automation of modern digital substations depends on the quality of electrical energy. At the present time to improve the reliability of the substation operation it is necessary to monitor indicators of quality of electric energy, allowing you to take organizational and technical solutions for their improvement. Monitoring the power quality at the input traction substation has shown that indicators such as the coefficient of the n-th harmonic component of the voltage does not meet the standards GOST 13109-97. The source of higher harmonics is a voltage Converter used on the locomotive. To eliminate higher harmonics in the supply network for traction substations will need to install power filters. Today, the USB-analyzer of power quality «Digital measurement system of power quality» type of CSICE of accuracy class 0.2. Work energy requires reliable and quality electricity supply to consumers. The new model of balancing energy market are bilateral contracts. The main task of this market, it ensure the stable and reliable operation of the unified energy system of Ukraine, that is, transmission and supply of electricity of appropriate quality. O.G. GrybD.A. GaponT.S. IerusalimovaD.V. BorodinA.V. DiachenkoNational Technical University "Kharkiv Polytechnic Institute"articlequalityhigher harmonicselectrical energysubstationmonitoringlossesElectrical engineering. Electronics. Nuclear engineeringTK1-9971ENRUUKElectrical engineering & Electromechanics, Iss 6, Pp 61-65 (2015) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN RU UK |
topic |
quality higher harmonics electrical energy substation monitoring losses Electrical engineering. Electronics. Nuclear engineering TK1-9971 |
spellingShingle |
quality higher harmonics electrical energy substation monitoring losses Electrical engineering. Electronics. Nuclear engineering TK1-9971 O.G. Gryb D.A. Gapon T.S. Ierusalimova D.V. Borodin A.V. Diachenko MONITORING OF ELECTRICAL ENERGY QUALITY ON THE TRACTION SUBSTATION INPUT |
description |
For the implementation of measures to maintain the quality of the energy industrial enterprises have to spend a significant material and monetary assets. In this regard, significant is the feasibility study of the allocation of such funds and, primarily, the determination of the economic damage arising from low quality of electricity. The reliability of the electricity metering system, relay protection and automation of modern digital substations depends on the quality of electrical energy. At the present time to improve the reliability of the substation operation it is necessary to monitor indicators of quality of electric energy, allowing you to take organizational and technical solutions for their improvement. Monitoring the power quality at the input traction substation has shown that indicators such as the coefficient of the n-th harmonic component of the voltage does not meet the standards GOST 13109-97. The source of higher harmonics is a voltage Converter used on the locomotive. To eliminate higher harmonics in the supply network for traction substations will need to install power filters. Today, the USB-analyzer of power quality «Digital measurement system of power quality» type of CSICE of accuracy class 0.2. Work energy requires reliable and quality electricity supply to consumers. The new model of balancing energy market are bilateral contracts. The main task of this market, it ensure the stable and reliable operation of the unified energy system of Ukraine, that is, transmission and supply of electricity of appropriate quality. |
format |
article |
author |
O.G. Gryb D.A. Gapon T.S. Ierusalimova D.V. Borodin A.V. Diachenko |
author_facet |
O.G. Gryb D.A. Gapon T.S. Ierusalimova D.V. Borodin A.V. Diachenko |
author_sort |
O.G. Gryb |
title |
MONITORING OF ELECTRICAL ENERGY QUALITY ON THE TRACTION SUBSTATION INPUT |
title_short |
MONITORING OF ELECTRICAL ENERGY QUALITY ON THE TRACTION SUBSTATION INPUT |
title_full |
MONITORING OF ELECTRICAL ENERGY QUALITY ON THE TRACTION SUBSTATION INPUT |
title_fullStr |
MONITORING OF ELECTRICAL ENERGY QUALITY ON THE TRACTION SUBSTATION INPUT |
title_full_unstemmed |
MONITORING OF ELECTRICAL ENERGY QUALITY ON THE TRACTION SUBSTATION INPUT |
title_sort |
monitoring of electrical energy quality on the traction substation input |
publisher |
National Technical University "Kharkiv Polytechnic Institute" |
publishDate |
2015 |
url |
https://doaj.org/article/a26bb7271c764656b2bbdc54b8a03a45 |
work_keys_str_mv |
AT oggryb monitoringofelectricalenergyqualityonthetractionsubstationinput AT dagapon monitoringofelectricalenergyqualityonthetractionsubstationinput AT tsierusalimova monitoringofelectricalenergyqualityonthetractionsubstationinput AT dvborodin monitoringofelectricalenergyqualityonthetractionsubstationinput AT avdiachenko monitoringofelectricalenergyqualityonthetractionsubstationinput |
_version_ |
1718384189836886016 |