MONITORING OF ELECTRICAL ENERGY QUALITY ON THE TRACTION SUBSTATION INPUT

For the implementation of measures to maintain the quality of the energy industrial enterprises have to spend a significant material and monetary assets. In this regard, significant is the feasibility study of the allocation of such funds and, primarily, the determination of the economic damage aris...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: O.G. Gryb, D.A. Gapon, T.S. Ierusalimova, D.V. Borodin, A.V. Diachenko
Formato: article
Lenguaje:EN
RU
UK
Publicado: National Technical University "Kharkiv Polytechnic Institute" 2015
Materias:
Acceso en línea:https://doaj.org/article/a26bb7271c764656b2bbdc54b8a03a45
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:a26bb7271c764656b2bbdc54b8a03a45
record_format dspace
spelling oai:doaj.org-article:a26bb7271c764656b2bbdc54b8a03a452021-12-02T16:20:09ZMONITORING OF ELECTRICAL ENERGY QUALITY ON THE TRACTION SUBSTATION INPUT2074-272X2309-3404https://doaj.org/article/a26bb7271c764656b2bbdc54b8a03a452015-12-01T00:00:00Zhttp://eie.khpi.edu.ua/article/view/54568/50958https://doaj.org/toc/2074-272Xhttps://doaj.org/toc/2309-3404For the implementation of measures to maintain the quality of the energy industrial enterprises have to spend a significant material and monetary assets. In this regard, significant is the feasibility study of the allocation of such funds and, primarily, the determination of the economic damage arising from low quality of electricity. The reliability of the electricity metering system, relay protection and automation of modern digital substations depends on the quality of electrical energy. At the present time to improve the reliability of the substation operation it is necessary to monitor indicators of quality of electric energy, allowing you to take organizational and technical solutions for their improvement. Monitoring the power quality at the input traction substation has shown that indicators such as the coefficient of the n-th harmonic component of the voltage does not meet the standards GOST 13109-97. The source of higher harmonics is a voltage Converter used on the locomotive. To eliminate higher harmonics in the supply network for traction substations will need to install power filters. Today, the USB-analyzer of power quality «Digital measurement system of power quality» type of CSICE of accuracy class 0.2. Work energy requires reliable and quality electricity supply to consumers. The new model of balancing energy market are bilateral contracts. The main task of this market, it ensure the stable and reliable operation of the unified energy system of Ukraine, that is, transmission and supply of electricity of appropriate quality. O.G. GrybD.A. GaponT.S. IerusalimovaD.V. BorodinA.V. DiachenkoNational Technical University "Kharkiv Polytechnic Institute"articlequalityhigher harmonicselectrical energysubstationmonitoringlossesElectrical engineering. Electronics. Nuclear engineeringTK1-9971ENRUUKElectrical engineering & Electromechanics, Iss 6, Pp 61-65 (2015)
institution DOAJ
collection DOAJ
language EN
RU
UK
topic quality
higher harmonics
electrical energy
substation
monitoring
losses
Electrical engineering. Electronics. Nuclear engineering
TK1-9971
spellingShingle quality
higher harmonics
electrical energy
substation
monitoring
losses
Electrical engineering. Electronics. Nuclear engineering
TK1-9971
O.G. Gryb
D.A. Gapon
T.S. Ierusalimova
D.V. Borodin
A.V. Diachenko
MONITORING OF ELECTRICAL ENERGY QUALITY ON THE TRACTION SUBSTATION INPUT
description For the implementation of measures to maintain the quality of the energy industrial enterprises have to spend a significant material and monetary assets. In this regard, significant is the feasibility study of the allocation of such funds and, primarily, the determination of the economic damage arising from low quality of electricity. The reliability of the electricity metering system, relay protection and automation of modern digital substations depends on the quality of electrical energy. At the present time to improve the reliability of the substation operation it is necessary to monitor indicators of quality of electric energy, allowing you to take organizational and technical solutions for their improvement. Monitoring the power quality at the input traction substation has shown that indicators such as the coefficient of the n-th harmonic component of the voltage does not meet the standards GOST 13109-97. The source of higher harmonics is a voltage Converter used on the locomotive. To eliminate higher harmonics in the supply network for traction substations will need to install power filters. Today, the USB-analyzer of power quality «Digital measurement system of power quality» type of CSICE of accuracy class 0.2. Work energy requires reliable and quality electricity supply to consumers. The new model of balancing energy market are bilateral contracts. The main task of this market, it ensure the stable and reliable operation of the unified energy system of Ukraine, that is, transmission and supply of electricity of appropriate quality.
format article
author O.G. Gryb
D.A. Gapon
T.S. Ierusalimova
D.V. Borodin
A.V. Diachenko
author_facet O.G. Gryb
D.A. Gapon
T.S. Ierusalimova
D.V. Borodin
A.V. Diachenko
author_sort O.G. Gryb
title MONITORING OF ELECTRICAL ENERGY QUALITY ON THE TRACTION SUBSTATION INPUT
title_short MONITORING OF ELECTRICAL ENERGY QUALITY ON THE TRACTION SUBSTATION INPUT
title_full MONITORING OF ELECTRICAL ENERGY QUALITY ON THE TRACTION SUBSTATION INPUT
title_fullStr MONITORING OF ELECTRICAL ENERGY QUALITY ON THE TRACTION SUBSTATION INPUT
title_full_unstemmed MONITORING OF ELECTRICAL ENERGY QUALITY ON THE TRACTION SUBSTATION INPUT
title_sort monitoring of electrical energy quality on the traction substation input
publisher National Technical University "Kharkiv Polytechnic Institute"
publishDate 2015
url https://doaj.org/article/a26bb7271c764656b2bbdc54b8a03a45
work_keys_str_mv AT oggryb monitoringofelectricalenergyqualityonthetractionsubstationinput
AT dagapon monitoringofelectricalenergyqualityonthetractionsubstationinput
AT tsierusalimova monitoringofelectricalenergyqualityonthetractionsubstationinput
AT dvborodin monitoringofelectricalenergyqualityonthetractionsubstationinput
AT avdiachenko monitoringofelectricalenergyqualityonthetractionsubstationinput
_version_ 1718384189836886016