Investigations on the oxidation of Zn-coated steel cables
The automotive component industry has been constantly being studying to improve its performance. Bowden cables are present in opening doors, moving windows and others. In braided cables formed by galvanized wires with Zn steel exposed to the usual environmental conditions, the generation of ZnO appe...
Guardado en:
Autores principales: | , , , , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
University of Belgrade - Faculty of Mechanical Engineering, Belgrade
2021
|
Materias: | |
Acceso en línea: | https://doaj.org/article/a4629a8348e14e419459995194c2cdc7 |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:a4629a8348e14e419459995194c2cdc7 |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:a4629a8348e14e419459995194c2cdc72021-12-05T21:01:45ZInvestigations on the oxidation of Zn-coated steel cables1451-20922406-128X10.5937/fme2103587Phttps://doaj.org/article/a4629a8348e14e419459995194c2cdc72021-01-01T00:00:00Zhttps://scindeks-clanci.ceon.rs/data/pdf/1451-2092/2021/1451-20922103587P.pdfhttps://doaj.org/toc/1451-2092https://doaj.org/toc/2406-128XThe automotive component industry has been constantly being studying to improve its performance. Bowden cables are present in opening doors, moving windows and others. In braided cables formed by galvanized wires with Zn steel exposed to the usual environmental conditions, the generation of ZnO appears, a phenomenon known as "white corrosion". The investigation consisted of mitigating the causes of the ZnO formation. Scanning electron microscopy (SEM) and Electron Probe Micro-Analyzer (EPMA) technology, allowed to detect that the generation of ZnO was induced by the presence of nucleating elements of ZnO on the surface of the steel cable before galvanizing with Zn. The S, Cl and O became visible in the interface between coating and substrate. This allowed concluding, under the coating, there were harmful products capable of triggering the ZnO nucleation reaction. So, the storage and cleaning of the steel wire before galvanizing is essential to prevent the ZnO formation.Pinto GustavoSilva F.J.G.Baptista A.Campilho Raul D.S.G.Viana F.University of Belgrade - Faculty of Mechanical Engineering, Belgradearticlezn-coated steel cables automotivewhite corrosionzinc oxideEngineering (General). Civil engineering (General)TA1-2040Mechanics of engineering. Applied mechanicsTA349-359ENFME Transactions, Vol 49, Iss 3, Pp 587-597 (2021) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
zn-coated steel cables automotive white corrosion zinc oxide Engineering (General). Civil engineering (General) TA1-2040 Mechanics of engineering. Applied mechanics TA349-359 |
spellingShingle |
zn-coated steel cables automotive white corrosion zinc oxide Engineering (General). Civil engineering (General) TA1-2040 Mechanics of engineering. Applied mechanics TA349-359 Pinto Gustavo Silva F.J.G. Baptista A. Campilho Raul D.S.G. Viana F. Investigations on the oxidation of Zn-coated steel cables |
description |
The automotive component industry has been constantly being studying to improve its performance. Bowden cables are present in opening doors, moving windows and others. In braided cables formed by galvanized wires with Zn steel exposed to the usual environmental conditions, the generation of ZnO appears, a phenomenon known as "white corrosion". The investigation consisted of mitigating the causes of the ZnO formation. Scanning electron microscopy (SEM) and Electron Probe Micro-Analyzer (EPMA) technology, allowed to detect that the generation of ZnO was induced by the presence of nucleating elements of ZnO on the surface of the steel cable before galvanizing with Zn. The S, Cl and O became visible in the interface between coating and substrate. This allowed concluding, under the coating, there were harmful products capable of triggering the ZnO nucleation reaction. So, the storage and cleaning of the steel wire before galvanizing is essential to prevent the ZnO formation. |
format |
article |
author |
Pinto Gustavo Silva F.J.G. Baptista A. Campilho Raul D.S.G. Viana F. |
author_facet |
Pinto Gustavo Silva F.J.G. Baptista A. Campilho Raul D.S.G. Viana F. |
author_sort |
Pinto Gustavo |
title |
Investigations on the oxidation of Zn-coated steel cables |
title_short |
Investigations on the oxidation of Zn-coated steel cables |
title_full |
Investigations on the oxidation of Zn-coated steel cables |
title_fullStr |
Investigations on the oxidation of Zn-coated steel cables |
title_full_unstemmed |
Investigations on the oxidation of Zn-coated steel cables |
title_sort |
investigations on the oxidation of zn-coated steel cables |
publisher |
University of Belgrade - Faculty of Mechanical Engineering, Belgrade |
publishDate |
2021 |
url |
https://doaj.org/article/a4629a8348e14e419459995194c2cdc7 |
work_keys_str_mv |
AT pintogustavo investigationsontheoxidationofzncoatedsteelcables AT silvafjg investigationsontheoxidationofzncoatedsteelcables AT baptistaa investigationsontheoxidationofzncoatedsteelcables AT campilhorauldsg investigationsontheoxidationofzncoatedsteelcables AT vianaf investigationsontheoxidationofzncoatedsteelcables |
_version_ |
1718371021000540160 |